Proximity Sensor
             
        
last update: October 2, 2023
| Types | Quadruple distance model | ||||
|---|---|---|---|---|---|
| Size | M8 | M12 | M18 | M30 | |
| Model | E2E-X4[]8 | E2E-X9[]12 | E2E-X14[]18 | E2E-X23[]30 | |
| Sensing distance | 4 mm±10% | 9 mm±10% | 14 mm±10% | 23 mm±10% | |
| Setting distance | 0 to 3 mm | 0 to 6.8 mm | 0 to 10.6 mm | 0 to 17.6 mm | |
| Differential travel | 15% max. of sensing distance | ||||
| Detectable object | Ferrous metals (For non-ferrous metals, refer to the Engineering Data on Catalog.) | ||||
| Standard sensing object | Iron, 12 × 12 × 1 mm | Iron, 27 × 27 × 1 mm | Iron, 42 × 42 × 1 mm | Iron, 69 × 69 × 1 mm | |
| Response frequency *1 | 700 Hz | 700 Hz | 350 Hz | 200 Hz | |
| Power supply voltage | 10 to 30 VDC (including 10% ripple (p-p)), Class 2 | ||||
| Current consumption | 1-output models: 16 mA max. | ||||
| Output configuration | B[] Models: PNP open collector, C[] Models: NPN open collector | ||||
| Operation mode (with sensing object approaching) | 1-output models (B1, C1): NO (Normally open), 1-output models (B2, C2): NC (Normally closed) | ||||
| Control output | Load current | 1-output models: 10 to 30 VDC, Class 2, 50 mA max. | |||
| Residual voltage | 1-output models: 2 V max. (Load current: 50 mA, Cable length: 2 m) | ||||
| Indicator *2 | In the Standard I/O mode (SIO mode): Operation indicator (orange, lit) and communication indicator (green, not lit) In the IO-Link communication mode (COM mode): Operation indicator (orange, lit) and communication indicator (green, blinking at 1 s intervals) | ||||
| Protection circuits | Power supply reverse polarity protection, Surge suppressor, Output short-circuit protection, Output reverse polarity protection | ||||
| Ambient temperature range | Operating: -25 to 60°C Storage: -25 to 70°C (with no icing or condensation) | Operating/Storage: -25 to 70°C (with no icing or condensation) | |||
| Ambient humidity range | Operating/Storage: 35% to 95% (with no condensation) | ||||
| Temperature influence | -15% to 25% max. of sensing distance at 23°C in the temperature range of -25 to 60°C | ±15% max. of sensing distance at 23°C in the temperature range of -25 to 70°C | |||
| Voltage influence | ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range | ||||
| Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | ||||
| Dielectric strength | 1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case | ||||
| Vibration resistance (destruction) | 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | ||||
| Shock resistance (destruction) | 500 m/s2 10 times each in X, Y, and Z directions | 1,000 m/s2 10 times each in X, Y, and Z directions | |||
| Degree of protection | Pre-wired Models, Pre-wired Connector Models: IEC 60529: IP67, ISO 20653 (old standard: DIN 40050 PART9): IP69K, JIS C 0920 Annex 1: IP67G, Passed OMRON's Oil-resistant Component Evaluation Standards *3 (Cutting oil type: specified in JIS K 2241: 2000; Temperature: 35°C max.) Connector Models: IEC 60529: IP67, ISO 20653 (old standard: DIN 40050 PART9): IP69K | ||||
| Connection method | Pre-wired Models (Standard cable length: 2 m), Pre-wired Connector Models (Standard cable length: 0.3 m) and Connector Models (M12 Connector, M8 (4-pin) Connector and M8 (3-pin) Connector) | ||||
| Weight*4 (packed state) | Pre-wired | Approx. 85 g | Approx. 95 g | Approx. 180 g | Approx. 260 g | 
| M12 Pre-wired Smartclick Connector | Approx. 55 g | Approx. 70 g | Approx. 115 g | Approx. 200 g | |
| Connector | Approx. 40 g (M8/M12 Connector) | Approx. 55 g | Approx. 95 g | Approx. 180 g | |
| Materials | Case | Nickel-plated brass | |||
| Sensing surface | Polybutylene terephthalat (PBT) | ||||
| Clamping nuts | Nickel-plated brass | ||||
| Toothed washers | Zinc-plated iron | ||||
| Cable | Vinyl chloride (PVC) Note: Material of Pre-wired Models and Pre-wired Connector Models. | ||||
| Main IO-Link functions*2 | Operation mode switching between NO and NC, self diagnosis enabling, excessive proximity judgment distance selecting, timer function of the control output and timer time selecting, instability output (IO-Link mode) ON delay timer time selecting function, monitor output, operating hours read-out, readout of the sensor internal temperature, and initial reset | ||||
| IO-Link Commun- ication specifica- tions *2 | IO-Link specification | Ver 1.1 | |||
| Baud rate | COM2 (38.4 kbps), COM3 (230.4 kbps) | ||||
| Data length | PD size: 2 bytes, OD size: 1 byte (M-sequence type: TYPE_2_2) | ||||
| Minimum cycle time | COM2: 2.3 ms, COM3: 0.4 ms | ||||
| Accessories | Instruction manual, Clamping nuts, Toothed washer | ||||
| Types | Triple distance model | ||||
|---|---|---|---|---|---|
| Size | M8 | M12 | M18 | M30 | |
| Model | E2E-X3[]8 | E2E-X6[]12 | E2E-X12[]18 | E2E-X22[]30 | |
| Sensing distance | 3 mm±10% | 6 mm±10% | 12 mm±10% | 22 mm±10% | |
| Setting distance | 0 to 2.4 mm | 0 to 4.8 mm | 0 to 9.6 mm | 0 to 16.8 mm | |
| Differential travel | 15% max. of sensing distance | ||||
| Detectable object | Ferrous metals (For non-ferrous metals, refer to the Engineering Data on Catalog.) | ||||
| Standard sensing object | Iron, 9 × 9 × 1 mm | Iron, 18 × 18 × 1 mm | Iron, 36 × 36 × 1 mm | Iron, 66 × 66 × 1 mm | |
| Response frequency *1 | 1,000 Hz | 800 Hz | 500 Hz | 200 Hz | |
| Power supply voltage | 10 to 30 VDC (including 10% ripple (p-p)), Class 2 | ||||
| Current consumption | 1-output models: 16 mA max. | 1-output models: 16 mA max., 2-output models: 20 mA max. | |||
| Output configuration | B[] Models: PNP open collector, C[] Models: NPN open collector | ||||
| Operation mode (with sensing object approaching) | 1-output models (B1, C1): NO (Normally open), 1-output models (B2, C2): NC (Normally closed) | 1-output models (B1, C1): NO (Normally open), 1-output models (B2, C2): NC (Normally closed), 2-output models (B3, C3): NO+NC (Normally open, Normally closed) | |||
| Control output | Load current | 1-output models: 10 to 30 VDC, Class 2, 100 mA max. | 1-output models: 10 to 30 VDC, Class 2, 100 mA max., 2-output models: 10 to 30 VDC, Class 2, 50 mA max. | ||
| Residual voltage | 1-output models: 2 V max. (Load current: 100 mA, Cable length: 2 m) | 1-output models: 2 V max. (Load current: 100 mA, Cable length: 2 m), 2-output models: 2 V max. (Load current: 50 mA, Cable length: 2 m) | |||
| Indicator *2 | In the Standard I/O mode (SIO mode): Operation indicator (orange, lit) and communication indicator (green, not lit) In the IO-Link communication mode (COM mode): Operation indicator (orange, lit) and communication indicator (green, blinking at 1 s intervals) | ||||
| Protection circuits | Power supply reverse polarity protection, Surge suppressor, Output short-circuit protection, Output reverse polarity protection | ||||
| Ambient temperature range | Operating/Storage: -25 to 70°C (with no icing or condensation) | ||||
| Ambient humidity range | Operating/Storage: 35% to 95% (with no condensation) | ||||
| Temperature influence | ±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C | ||||
| Voltage influence | ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range | ||||
| Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | ||||
| Dielectric strength | 1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case | ||||
| Vibration resistance (destruction) | 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | ||||
| Shock resistance (destruction) | 500 m/s2 10 times each in X, Y, and Z directions | 1,000 m/s2 10 times each in X, Y, and Z directions | |||
| Degree of protection | Pre-wired Models, Pre-wired Connector Models: IEC 60529: IP67, ISO 20653 (old standard: DIN 40050 PART9): IP69K, JIS C 0920 Annex 1: IP67G, Passed OMRON's Oil-resistant Component Evaluation Standards *3 (Cutting oil type: specified in JIS K 2241: 2000; Temperature: 35°C max.) Connector Models: IEC 60529: IP67, ISO 20653 (old standard: DIN 40050 PART9): IP69K | ||||
| Connection method | Pre-wired Models (Standard cable length: 2 m), Pre-wired Connector Models (Standard cable length: 0.3 m) and Connector Models (M12 Connector, M8 (4-pin) Connector and M8 (3-pin) Connector) | ||||
| Weight*4 (packed state) | Pre-wired | Approx. 85 g | Approx. 95 g | Approx. 180 g | Approx. 260 g | 
| M12 Pre-wired Smartclick Connector | Approx. 55 g | Approx. 70 g | Approx. 115 g | Approx. 200 g | |
| Connector | Approx. 40 g (M8/M12 Connector) | Approx. 55 g | Approx. 95 g | Approx. 180 g | |
| Materials | Case | Nickel-plated brass | |||
| Sensing surface | Polybutylene terephthalat (PBT) | ||||
| Clamping nuts | Nickel-plated brass | ||||
| Toothed washers | Zinc-plated iron | ||||
| Cable | Vinyl chloride (PVC) Note: Material of Pre-wired Models and Pre-wired Connector Models. | ||||
| Main IO-Link functions*2 | Operation mode switching between NO and NC, self diagnosis enabling, excessive proximity judgment distance selecting, timer function of the control output and timer time selecting, instability output (IO-Link mode) ON delay timer time selecting function, monitor output, operating hours read-out, readout of the sensor internal temperature, and initial reset | ||||
| IO-Link Commun- ication specifica- tions *2 | IO-Link specification | Ver 1.1 | |||
| Baud rate | COM2 (38.4 kbps), COM3 (230.4 kbps) | ||||
| Data length | PD size: 2 bytes, OD size: 1 byte (M-sequence type: TYPE_2_2) | ||||
| Minimum cycle time | COM2: 2.3 ms, COM3: 0.4 ms | ||||
| Accessories | Instruction manual, Clamping nuts, Toothed washer | ||||
| Types | Quadruple distance model | ||||
|---|---|---|---|---|---|
| Size | M8 | M12 | M18 | M30 | |
| Model | E2E-X8M[]8 | E2E-X16M[]12 | E2E-X30M[]18 | E2E-X50M[]30 | |
| Sensing distance | 8 mm±10% | 16 mm±10% | 30 mm±10% | 50 mm±10% | |
| Setting distance | 0 to 6 mm | 0 to 12.2 mm | 0 to 23 mm | 0 to 38.2 mm | |
| Differential travel | 15% max. of sensing distance | ||||
| Detectable object | Ferrous metals (For non-ferrous metals, refer to the Engineering Data on Catalog.) | ||||
| Standard sensing object | Iron, 24 × 24 × 1 mm | Iron, 48 × 48 × 1 mm | Iron, 90 × 90 × 1 mm | Iron, 150 × 150 × 1 mm | |
| Response frequency *1 | 500 Hz | 400 Hz | 200 Hz | 100 Hz | |
| Power supply voltage | 10 to 30 VDC (including 10% ripple (p-p)), Class 2 | ||||
| Current consumption | 1-output models: 16 mA max. | ||||
| Output configuration | B[] Models: PNP open collector C[] Models: NPN open collector | ||||
| Operation mode (with sensing object approaching) | 1-output models (B1, C1): NO (Normally open), 1-output models (B2, C2): NC (Normally closed) | ||||
| Control output | Load current | 1-output models: 10 to 30 VDC, Class 2, 50 mA max. | |||
| Residual voltage | 1-output models: 2 V max. (Load current: 50 mA, Cable length: 2 m) | ||||
| Indicator *2 | In the Standard I/O mode (SIO mode): Operation indicator (orange, lit) and communication indicator (green, not lit) In the IO-Link communication mode (COM mode): Operation indicator (orange, lit) and communication indicator (green, blinking at 1 s intervals) | ||||
| Protection circuits | Power supply reverse polarity protection, Surge suppressor, Output short-circuit protection, Output reverse polarity protection | ||||
| Ambient temperature range | Operating/Storage: -25 to 70°C (with no icing or condensation) | ||||
| Ambient humidity range | Operating/Storage: 35% to 95% (with no condensation) | ||||
| Temperature influence | ±15% max. of sensing distance at 23°C in the temperature range of -25 to 70°C | ||||
| Voltage influence | ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range | ||||
| Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | ||||
| Dielectric strength | 1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case | ||||
| Vibration resistance (destruction) | 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | ||||
| Shock resistance (destruction) | 500 m/s2 10 times each in X, Y, and Z directions | 1,000 m/s2 10 times each in X, Y, and Z directions | |||
| Degree of protection | Pre-wired Models, Pre-wired Connector Models: IEC 60529:IP67, ISO 20653 (old standard: DIN 40050 PART9): IP69K, JIS C 0920 Annex 1: IP67G, Passed OMRON's Oil-resistant Component Evaluation Standards *3 (Cutting oil type: specified in JIS K 2241: 2000; Temperature: 35°C max.) Connector Models: IEC 60529: IP67, ISO 20653 (old standard: DIN 40050 PART9): IP69K | ||||
| Connection method | Pre-wired Models (Standard cable length: 2 m), Pre-wired Connector Models (Standard cable length: 0.3 m) and Connector Models (M12 Connector, M8 (4-pin) Connector and M8 (3-pin) Connector) | ||||
| Weight*4 (packed state) | Pre-wired | Approx. 85 g | Approx. 95 g | Approx. 190 g | Approx. 310 g | 
| M12 Pre-wired Smartclick Connector | Approx. 55 g | Approx. 70 g | Approx. 125 g | Approx. 250 g | |
| Connector | Approx. 40 g (M8/M12 Connector) | Approx. 55 g | Approx. 105 g | Approx. 230 g | |
| Materials | Case | Stainless (SUS303) | Nickel-plated brass | ||
| Sensing surface | Polybutylene terephthalat (PBT) | ||||
| Clamping nuts | Nickel-plated brass | ||||
| Toothed washers | Zinc-plated iron | ||||
| Cable | Vinyl chloride (PVC) Note: Material of Pre-wired Models and Pre-wired Connector Models. | ||||
| Main IO-Link functions*2 | Operation mode switching between NO and NC, self diagnosis enabling, excessive proximity judgment distance selecting, timer function of the control output and timer time selecting, instability output (IO-Link mode) ON delay timer time selecting function, monitor output, operating hours read-out, readout of the sensor internal temperature, and initial reset | ||||
| IO-Link Commun- ication specifica- tions *2 | IO-Link specification | Ver1.1 | |||
| Baud rate | COM2 (38.4 kbps), COM3 (230.4 kbps) | ||||
| Data length | PD size: 2 bytes, OD size: 1 byte (M-sequence type: TYPE_2_2) | ||||
| Minimum cycle time | COM2: 2.3 ms, COM3: 0.4 ms | ||||
| Accessories | Instruction manual, Clamping nuts, Toothed washer | ||||
| Types | Triple distance model | ||||
|---|---|---|---|---|---|
| Size | M8 | M12 | M18 | M30 | |
| Model | E2E-X6M[]8 | E2E-X10M[]12 | E2E-X20M[]18 | E2E-X40M[]30 | |
| Sensing distance | 6 mm±10% | 10 mm±10% | 20 mm±10% | 40 mm±10% | |
| Setting distance | 0 to 4.8 mm | 0 to 8 mm | 0 to 16 mm | 0 to 32 mm | |
| Differential travel | 15% max. of sensing distance | ||||
| Detectable object | Ferrous metals (For non-ferrous metals, refer to the Engineering Data on Catalog.) | ||||
| Standard sensing object | Iron, 18 × 18 × 1 mm | Iron, 30 × 30 × 1 mm | Iron, 60 × 60 × 1 mm | Iron, 120 × 120 × 1 mm | |
| Response frequency *1 | 800 Hz | 400 Hz | 200 Hz | 100 Hz | |
| Power supply voltage | 10 to 30 VDC (including 10% ripple (p-p)), Class 2 | ||||
| Current consumption | 1-output models: 16 mA max. | 1-output models: 16 mA max., 2-output models: 20 mA max. | |||
| Output configuration | B[] Models: PNP open collector C[] Models: NPN open collector | ||||
| Operation mode (with sensing object approaching) | 1-output models (B1, C1): NO (Normally open), 1-output models (B2, C2): NC (Normally closed) | 1-output models (B1, C1): NO (Normally open), 1-output models (B2, C2): NC (Normally closed), 2-output models (B3, C3): NO+NC (Normally open, Normally closed) | |||
| Control output | Load current | 1-output models: 10 to 30 VDC, Class 2, 100 mA max. | 1-output models: 10 to 30 VDC, Class 2, 100 mA max., 2-output models: 10 to 30 VDC, Class 2, 50 mA max. | ||
| Residual voltage | 1-output models: 2 V max. (Load current: 100 mA, Cable length: 2 m) | 1-output models: 2 V max. (Load current: 100 mA, Cable length: 2 m), 2-output models: 2 V max. (Load current: 50 mA, Cable length: 2 m) | |||
| Indicator *2 | In the Standard I/O mode (SIO mode): Operation indicator (orange, lit) and communication indicator (green, not lit) In the IO-Link communication mode (COM mode): Operation indicator (orange, lit) and communication indicator (green, blinking at 1 s intervals) | ||||
| Protection circuits | Power supply reverse polarity protection, Surge suppressor, Output short-circuit protection, Output reverse polarity protection | ||||
| Ambient temperature range | Operating/Storage: -25 to 70°C (with no icing or condensation) | ||||
| Ambient humidity range | Operating/Storage: 35% to 95% (with no condensation) | ||||
| Temperature influence | ±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C | ||||
| Voltage influence | ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range | ||||
| Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | ||||
| Dielectric strength | 1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case | ||||
| Vibration resistance (destruction) | 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | ||||
| Shock resistance (destruction) | 500 m/s2 10 times each in X, Y, and Z directions | 1,000 m/s2 10 times each in X, Y, and Z directions | |||
| Degree of protection | Pre-wired Models, Pre-wired Connector Models: IEC 60529:IP67, ISO 20653 (old standard: DIN 40050 PART9): IP69K, JIS C 0920 Annex 1: IP67G, Passed OMRON's Oil-resistant Component Evaluation Standards *3 (Cutting oil type: specified in JIS K 2241: 2000; Temperature: 35°C max.) Connector Models: IEC 60529: IP67, ISO 20653 (old standard: DIN 40050 PART9): IP69K | ||||
| Connection method | Pre-wired Models (Standard cable length: 2 m), Pre-wired Connector Models (Standard cable length: 0.3 m) and Connector Models (M12 Connector, M8 (4-pin) Connector and M8 (3-pin) Connector) | ||||
| Weight*4 (packed state) | Pre-wired | Approx. 85 g | Approx. 95 g | Approx. 190 g | Approx. 280 g | 
| M12 Pre-wired Smartclick Connector | Approx. 55 g | Approx. 70 g | Approx. 125 g | Approx. 220 g | |
| Connector | Approx. 40 g (M8/M12 Connector) | Approx. 55 g | Approx. 105 g | Approx. 200 g | |
| Materials | Case | Stainless (SUS303) | Nickel-plated brass | ||
| Sensing surface | Polybutylene terephthalat (PBT) | ||||
| Clamping nuts | Nickel-plated brass | ||||
| Toothed washers | Zinc-plated iron | ||||
| Cable | Vinyl chloride (PVC) Note: Material of Pre-wired Models and Pre-wired Connector Models. | ||||
| Main IO-Link functions*2 | Operation mode switching between NO and NC, self diagnosis enabling, excessive proximity judgment distance selecting, timer function of the control output and timer time selecting, instability output (IO-Link mode) ON delay timer time selecting function, monitor output, operating hours read-out, readout of the sensor internal temperature, and initial reset | ||||
| IO-Link Commun- ication specifica- tions *2 | IO-Link specification | Ver1.1 | |||
| Baud rate | COM2 (38.4 kbps), COM3 (230.4 kbps) | ||||
| Data length | PD size: 2 bytes, OD size: 1 byte (M-sequence type: TYPE_2_2) | ||||
| Minimum cycle time | COM2: 2.3 ms, COM3: 0.4 ms | ||||
| Accessories | Instruction manual, Clamping nuts, Toothed washer | ||||
| Types | Double distance model | ||||
|---|---|---|---|---|---|
| Size | M8 | M12 | M18 | M30 | |
| Model | E2E-X2[]8 | E2E-X4[]12 | E2E-X8[]18 | E2E-X15[]30 | |
| Sensing distance | 2 mm±10% | 4 mm±10% | 8 mm±10% | 15 mm±10% | |
| Setting distance | 0 to 1.6 mm | 0 to 3.2 mm | 0 to 6.4 mm | 0 to 12 mm | |
| Differential travel | 15% max. of sensing distance | ||||
| Detectable object | Ferrous metals (For non-ferrous metals, refer to the Engineering Data on Catalog.) | ||||
| Standard sensing object | Iron, 8 × 8 × 1 mm | Iron, 12 × 12 × 1 mm | Iron, 24 × 24 × 1 mm | Iron, 45 × 45 × 1 mm | |
| Response frequency *1 | 1,500 Hz | 1,000 Hz | 500 Hz | 250 Hz | |
| Power supply voltage | 10 to 30 VDC (including 10% ripple (p-p)), Class 2 | ||||
| Current consumption | 1-output models: 16 mA max. 2-output models: 20 mA max. | ||||
| Output configuration | B[] Models: PNP open collector C[] Models: NPN open collector | ||||
| Operation mode (with sensing object approaching) | 1-output models (B1, C1): NO (Normally open), 1-output models (B2, C2): NC (Normally closed), 2-output models (B3, C3): NO+NC (Normally open, Normally closed) *3 | ||||
| Control output | Load current | 1-output models: 10 to 30 VDC, Class 2, 200 mA max., (-40 to 70°C), 100 mA max., (70 to 85°C) 2-output models: 10 to 30 VDC, Class 2, 50 mA max. | 1-output models: 10 to 30 VDC, Class 2, 200 mA max., 2-output models: 10 to 30 VDC, Class 2, 100 mA max. | ||
| Residual voltage | 1-output models: 2 V max. (Load current: 200 mA, Cable length: 2 m), 2-output models: 2 V max. (Load current: 50 mA, Cable length: 2 m) | 1-output models: 2 V max. (Load current: 200 mA, Cable length: 2 m), 2-output models: 2 V max. (Load current: 100 mA, Cable length: 2 m) | |||
| Indicator *2 | In the Standard I/O mode (SIO mode): Operation indicator (orange, lit) and communication indicator (green, not lit) In the IO-Link communication mode (COM mode): Operation indicator (orange, lit) and communication indicator (green, blinking at 1 s intervals) | ||||
| Protection circuits | Power supply reverse polarity protection, Surge suppressor, Output short-circuit protection, Output reverse polarity protection | ||||
| Ambient temperature range | Operating/Storage: -40 to 85°C (with no icing or condensation) Note: The UL temperature rating for M12 Pre-wired Connector Models is -25 to 70°C. | ||||
| Ambient humidity range | Operating/Storage: 35% to 95% (with no condensation) | ||||
| Temperature influence | ±15% max. of sensing distance at 23°C in the temperature range of -40 to 85°C ±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C | ||||
| Voltage influence | ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range | ||||
| Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | ||||
| Dielectric strength | 1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case | ||||
| Vibration resistance (destruction) | 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | ||||
| Shock resistance (destruction) | 500 m/s2 10 times each in X, Y, and Z directions | 1,000 m/s2 10 times each in X, Y, and Z directions | |||
| Degree of protection | Pre-wired Models, Pre-wired Connector Models: IEC 60529:IP67, ISO 20653 (old standard: DIN 40050 PART9): IP69K, JIS C 0920 Annex 1: IP67G, Passed OMRON's Oil-resistant Component Evaluation Standards *4 (Cutting oil type: specified in JIS K 2241:2000; Temperature: 35°C max.) Connector Models: IEC 60529: IP67, ISO 20653 (old standard: DIN 40050 PART9): IP69K | ||||
| Connection method | Pre-wired Models (Standard cable length: 2 m), Pre-wired Connector Models (Standard cable length: 0.3 m) and Connector Models (M12 Connector, M8 (4-pin) Connector and M8 (3-pin) Connector) | ||||
| Weight *5 (packed state) | Pre-wired | Approx. 85 g | Approx. 95 g | Approx. 170 g | Approx. 240 g | 
| M12 Pre-wired Smartclick Connector | Approx. 55 g | Approx. 70 g | Approx. 105 g | Approx. 170 g | |
| Connector | Approx. 40 g (M8/M12 Connector) | Approx. 55 g | Approx. 85 g | Approx. 160 g | |
| Materials | Case | Stainless (SUS303) | Nickel-plated brass | ||
| Sensing surface | Polybutylene terephthalat (PBT) | ||||
| Clamping nuts | Nickel-plated brass | ||||
| Toothed washers | Zinc-plated iron | ||||
| Cable | Vinyl chloride (PVC) Note: Material of Pre-wired Models and Pre-wired Connector Models. | ||||
| Main IO-Link functions *2 | Operation mode switching between NO and NC, self diagnosis enabling, excessive proximity judgment distance selecting, timer function of the control output and timer time selecting, instability output (IO-Link mode) ON delay timer time selecting function, monitor output, operating hours read-out, readout of the sensor internal temperature, and initial reset | ||||
| IO-Link Commun- ication specifica- tions *2 | IO-Link specification | Ver1.1 | |||
| Baud rate | COM2 (38.4 kbps), COM3 (230.4 kbps) | ||||
| Data length | PD size: 2 bytes, OD size: 1 byte (M-sequence type: TYPE_2_2) | ||||
| Minimum cycle time | COM2: 2.3 ms, COM3: 0.4 ms | ||||
| Accessories | Instruction manual, Clamping nuts, Toothed washer | ||||
| Types | Single distance model | ||||
|---|---|---|---|---|---|
| Size | M8 | M12 | M18 | M30 | |
| Model | E2E-X1R5[]8 | E2E-X2[]12 | E2E-X5[]18 | E2E-X10[]30 | |
| Sensing distance | 1.5 mm±10% | 2 mm±10% | 5 mm±10% | 10 mm±10% | |
| Setting distance | 0 to 1.2 mm | 0 to 1.6 mm | 0 to 4 mm | 0 to 8 mm | |
| Differential travel | 10% max. of sensing distance | ||||
| Detectable object | Ferrous metals (For non-ferrous metals, refer to the Engineering Data on Catalog.) | ||||
| Standard sensing object | Iron, 8 × 8 × 1 mm | Iron, 12 × 12 × 1 mm | Iron, 18 × 18 × 1 mm | Iron, 30 × 30 × 1 mm | |
| Response frequency *1 | 2,000 Hz | 1,500 Hz | 600 Hz | 400 Hz | |
| Power supply voltage | 10 to 30 VDC (including 10% ripple (p-p)), Class 2 | ||||
| Current consumption | 1-output models: 16 mA max. 2-output models: 20 mA max. | ||||
| Output configuration | B[] Models: PNP open collector C[] Models: NPN open collector | ||||
| Operation mode (with sensing object approaching) | 1-output models (B1, C1): NO (Normally open), 1-output models (B2, C2): NC (Normally closed), 2-output models (B3, C3): NO+NC (Normally open, Normally closed) *3 | ||||
| Control output | Load current | 1-output models: 10 to 30 VDC, Class 2, 200 mA max., (-40 to 70°C), 100 mA max., (70 to 85°C) 2-output models: 10 to 30 VDC, Class 2, 50 mA max. | 1-output models: 10 to 30 VDC, Class 2, 200 mA max., 2-output models: 10 to 30 VDC, Class 2, 100 mA max. | ||
| Residual voltage | 1-output models: 2 V max. (Load current: 200 mA, Cable length: 2 m), 2-output models: 2 V max. (Load current: 50 mA, Cable length: 2 m) | 1-output models: 2 V max. (Load current: 200 mA, Cable length: 2 m), 2-output models: 2 V max. (Load current: 100 mA, Cable length: 2 m) | |||
| Indicator *2 | In the Standard I/O mode (SIO mode): Operation indicator (orange, lit) and communication indicator (green, not lit) In the IO-Link communication mode (COM mode): Operation indicator (orange, lit) and communication indicator (green, blinking at 1 s intervals) | ||||
| Protection circuits | Power supply reverse polarity protection, Surge suppressor, Output short-circuit protection, Output reverse polarity protection | ||||
| Ambient temperature range | Operating/Storage: -40 to 85°C (with no icing or condensation) Note: The UL temperature rating for M12 Pre-wired Connector Models is -25 to 70°C. | ||||
| Ambient humidity range | Operating/Storage: 35% to 95% (with no condensation) | ||||
| Temperature influence | ±15% max. of sensing distance at 23°C in the temperature range of -40 to 85°C ±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C | ||||
| Voltage influence | ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range | ||||
| Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | ||||
| Dielectric strength | 1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case | ||||
| Vibration resistance (destruction) | 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | ||||
| Shock resistance (destruction) | 500 m/s2 10 times each in X, Y, and Z directions | 1,000 m/s2 10 times each in X, Y, and Z directions | |||
| Degree of protection | Pre-wired Models, Pre-wired Connector Models: IEC 60529:IP67, ISO 20653 (old standard: DIN 40050 PART9): IP69K, JIS C 0920 Annex 1: IP67G, Passed OMRON's Oil-resistant Component Evaluation Standards *4 (Cutting oil type: specified in JIS K 2241:2000; Temperature: 35°C max.) Connector Models: IEC 60529: IP67, ISO 20653 (old standard: DIN 40050 PART9): IP69K | ||||
| Connection method | Pre-wired Models (Standard cable length: 2 m), Pre-wired Connector Models (Standard cable length: 0.3 m) and Connector Models (M12 Connector, M8 (4-pin) Connector and M8 (3-pin) Connector) | ||||
| Weight *5 (packed state) | Pre-wired | Approx. 85 g | Approx. 95 g | Approx. 170 g | Approx. 240 g | 
| M12 Pre-wired Smartclick Connector | Approx. 55 g | Approx. 70 g | Approx. 105 g | Approx. 170 g | |
| Connector | Approx. 40 g (M8/M12 Connector) | Approx. 55 g | Approx. 85 g | Approx. 160 g | |
| Materials | Case | Stainless (SUS303) | Nickel-plated brass | ||
| Sensing surface | Polybutylene terephthalat (PBT) | ||||
| Clamping nuts | Nickel-plated brass | ||||
| Toothed washers | Zinc-plated iron | ||||
| Cable | Vinyl chloride (PVC) Note: Material of Pre-wired Models and Pre-wired Connector Models. | ||||
| Main IO-Link functions *2 | Operation mode switching between NO and NC, self diagnosis enabling, excessive proximity judgment distance selecting, timer function of the control output and timer time selecting, instability output (IO-Link mode) ON delay timer time selecting function, monitor output, operating hours read-out, readout of the sensor internal temperature, and initial reset | ||||
| IO-Link Commun- ication specifica- tions *2 | IO-Link specification | Ver1.1 | |||
| Baud rate | COM2 (38.4 kbps), COM3 (230.4 kbps) | ||||
| Data length | PD size: 2 bytes, OD size: 1 byte (M-sequence type: TYPE_2_2) | ||||
| Minimum cycle time | COM2: 2.3 ms, COM3: 0.4 ms | ||||
| Accessories | Instruction manual, Clamping nuts, Toothed washer | ||||
| Types | Double distance model | ||||
|---|---|---|---|---|---|
| Size | M8 | M12 | M18 | M30 | |
| Model | E2E-X4M[]8 | E2E-X8M[]12 | E2E-X16M[]18 | E2E-X30M[]30 | |
| Sensing distance | 4 mm±10% | 8 mm±10% | 16 mm±10% | 30 mm±10% | |
| Setting distance | 0 to 3.2 mm | 0 to 6.4 mm | 0 to 12.8 mm | 0 to 24 mm | |
| Differential travel | 15% max. of sensing distance | ||||
| Detectable object | Ferrous metals (For non-ferrous metals, refer to the Engineering Data on Catalog.) | ||||
| Standard sensing object | Iron, 12 × 12 × 1 mm | Iron, 24 × 24 × 1 mm | Iron, 48 × 48 × 1 mm | Iron, 90 × 90 × 1 mm | |
| Response frequency *1 | 1,000 Hz | 800 Hz | 400 Hz | 100 Hz | |
| Power supply voltage | 10 to 30 VDC (including 10% ripple (p-p)), Class 2 | ||||
| Current consumption | 1-output models: 16 mA max. 2-output models: 20 mA max. | ||||
| Output configuration | B[] Models: PNP open collector C[] Models: NPN open collector | ||||
| Operation mode (with sensing object approaching) | 1-output models (B1, C1): NO (Normally open), 1-output models (B2, C3): NC (Normally closed) 2-output models (B3, C3): NO+NC (Normally open, Normally closed) *3 | ||||
| Control output | Load current | 1-output models: 10 to 30 VDC, Class 2, 200 mA max., (-40 to 70°C), 100 mA max., (70 to 85°C) 2-output models: 10 to 30 VDC, Class 2, 50 mA max. | 1-output models: 10 to 30 VDC, Class 2, 200 mA max., 2-output models: 10 to 30 VDC, Class 2, 100 mA max. | ||
| Residual voltage | 1-output models: 2 V max. (Load current: 200 mA, Cable length: 2 m), 2-output models: 2 V max. (Load current: 50 mA, Cable length: 2 m) | 1-output models: 2 V max. (Load current: 200 mA, Cable length: 2 m), 2-output models: 2 V max. (Load current: 100 mA, Cable length: 2 m) | |||
| Indicator *2 | In the Standard I/O mode (SIO mode): Operation indicator (orange, lit) and communication indicator (green, not lit) In the IO-Link communication mode (COM mode): Operation indicator (orange, lit) and communication indicator (green, blinking at 1 s intervals) | ||||
| Protection circuits | Power supply reverse polarity protection, Surge suppressor, Output short-circuit protection, Output reverse polarity protection | ||||
| Ambient temperature range | Operating/Storage: -40 to 85°C (with no icing or condensation) Note: The UL temperature rating for M12 Pre-wired Connector Models is -25 to 70°C. | ||||
| Ambient humidity range | Operating/Storage: 35% to 95% (with no condensation) | ||||
| Temperature influence | ±15% max. of sensing distance at 23°C in the temperature range of -40 to 85°C ±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C | ||||
| Voltage influence | ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range | ||||
| Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | ||||
| Dielectric strength | 1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case | ||||
| Vibration resistance (destruction) | 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | ||||
| Shock resistance (destruction) | 500 m/s2 10 times each in X, Y, and Z directions | 1,000 m/s2 10 times each in X, Y, and Z directions | |||
| Degree of protection | Pre-wired Models, Pre-wired Connector Models: IEC 60529:IP67, ISO 20653 (old standard: DIN 40050 PART9): IP69K, JIS C 0920 Annex 1: IP67G, Passed OMRON's Oil-resistant Component Evaluation Standards *4 (Cutting oil type: specified in JIS K 2241:2000; Temperature: 35°C max.) Connector Models: IEC 60529:IP67, ISO 20653 (old standard: DIN 40050 PART9): IP69K | ||||
| Connection method | Pre-wired Models (Standard cable length: 2 m), Pre-wired Connector Models (Standard cable length: 0.3 m) and Models (M12 Connector, M8 (4-pin) Connector and M8 (3-pin) Connector) | ||||
| Weight *5 (packed state) | Pre-wired | Approx. 85 g | Approx. 95 g | Approx. 170 g | Approx. 280 g | 
| M12 Pre-wired Smartclick Connector | Approx. 55 g | Approx. 70 g | Approx. 105 g | Approx. 220 g | |
| Connector | Approx. 40 g (M8/M12 Connector) | Approx. 55 g | Approx. 85 g | Approx. 200 g | |
| Materials | Case | Stainless (SUS303) | Nickel-plated brass | ||
| Sensing surface | Polybutylene terephthalat (PBT) | ||||
| Clamping nuts | Nickel-plated brass | ||||
| Toothed washers | Zinc-plated iron | ||||
| Cable | Vinyl chloride (PVC) Note: Material of Pre-wired Models and Pre-wired Connector Models. | ||||
| Main IO-Link functions *2 | Operation mode switching between NO and NC, self diagnosis enabling, excessive proximity judgment distance selecting, timer function of the control output and timer time selecting, instability output (IO-Link mode) ON delay timer time selecting function, monitor output, operating hours read-out, readout of the sensor internal temperature, and initial reset | ||||
| IO-Link Commun- ication specifica- tions *2 | IO-Link specification | Ver 1.1 | |||
| Baud rate | COM2 (38.4 kbps), COM3 (230.4 kbps) | ||||
| Data length | PD size: 2 bytes, OD size: 1 byte (M-sequence type: TYPE_2_2) | ||||
| Minimum cycle time | COM2: 2.3 ms, COM3: 0.4 ms | ||||
| Accessories | Instruction manual, Clamping nuts, Toothed washer | ||||
| Types | Single distance model | ||||
|---|---|---|---|---|---|
| Size | M8 | M12 | M18 | M30 | |
| Model | E2E-X2M[]8 | E2E-X5M[]12 | E2E-X10M[]18 | E2E-X18M[]30 | |
| Sensing distance | 2 mm±10% | 5 mm±10% | 10 mm±10% | 18 mm±10% | |
| Setting distance | 0 to 1.6 mm | 0 to 4 mm | 0 to 8 mm | 0 to 14.4 mm | |
| Differential travel | 10% max. of sensing distance | ||||
| Detectable object | Ferrous metals (For non-ferrous metals, refer to the Engineering Data on Catalog.) | ||||
| Standard sensing object | Iron, 8 × 8 × 1 mm | Iron, 15 × 15 × 1 mm | Iron, 30 × 30 × 1 mm | Iron, 54 × 54 × 1 mm | |
| Response frequency *1 | 1,000 Hz | 800 Hz | 400 Hz | 100 Hz | |
| Power supply voltage | 10 to 30 VDC (including 10% ripple (p-p)), Class 2 | ||||
| Current consumption | 1-output models: 16 mA max. 2-output models: 20 mA max. | ||||
| Output configuration | B[] Models: PNP open collector C[] Models: NPN open collector | ||||
| Operation mode (with sensing object approaching) | 1-output models (B1, C1): NO (Normally open), 1-output models (B2, C3): NC (Normally closed) 2-output models (B3, C3): NO+NC (Normally open, Normally closed) *3 | ||||
| Control output | Load current | 1-output models: 10 to 30 VDC, Class 2, 200 mA max., (-40 to 70°C), 100 mA max., (70 to 85°C) 2-output models: 10 to 30 VDC, Class 2, 50 mA max. | 1-output models: 10 to 30 VDC, Class 2, 200 mA max., 2-output models: 10 to 30 VDC, Class 2, 100 mA max. | ||
| Residual voltage | 1-output models: 2 V max. (Load current: 200 mA, Cable length: 2 m), 2-output models: 2 V max. (Load current: 50 mA, Cable length: 2 m) | 1-output models: 2 V max. (under load current of 200 mA with cable length of 2 m), 2-output models: 2 V max. (under load current of 100 mA with cable length of 2 m) | |||
| Indicator *2 | In the Standard I/O mode (SIO mode): Operation indicator (orange, lit) and communication indicator (green, not lit) In the IO-Link communication mode (COM mode): Operation indicator (orange, lit) and communication indicator (green, blinking at 1 s intervals) | ||||
| Protection circuits | Power supply reverse polarity protection, Surge suppressor, Output short-circuit protection, Output reverse polarity protection | ||||
| Ambient temperature range | Operating/Storage: -40 to 85°C (with no icing or condensation) Note: The UL temperature rating for M12 Pre-wired Connector Models is -25 to 70°C. | ||||
| Ambient humidity range | Operating/Storage: 35% to 95% (with no condensation) | ||||
| Temperature influence | ±15% max. of sensing distance at 23°C in the temperature range of -40 to 85°C ±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C | ||||
| Voltage influence | ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range | ||||
| Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | ||||
| Dielectric strength | 1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case | ||||
| Vibration resistance (destruction) | 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | ||||
| Shock resistance (destruction) | 500 m/s2 10 times each in X, Y, and Z directions | 1,000 m/s2 10 times each in X, Y, and Z directions | |||
| Degree of protection | Pre-wired Models, Pre-wired Connector Models: IEC 60529:IP67, ISO 20653 (old standard: DIN 40050 PART9): IP69K, JIS C 0920 Annex 1: IP67G, Passed OMRON's Oil-resistant Component Evaluation Standards *4 (Cutting oil type: specified in JIS K 2241:2000; Temperature: 35°C max.) Connector Models: IEC 60529:IP67, ISO 20653 (old standard: DIN 40050 PART9): IP69K | ||||
| Connection method | Pre-wired Models (Standard cable length: 2 m), Pre-wired Connector Models (Standard cable length: 0.3 m) and Models (M12 Connector, M8 (4-pin) Connector and M8 (3-pin) Connector) | ||||
| Weight *5 (packed state) | Pre-wired | Approx. 85 g | Approx. 95 g | Approx. 170 g | Approx. 240 g | 
| M12 Pre-wired Smartclick Connector | Approx. 55 g | Approx. 70 g | Approx. 105 g | Approx. 170 g | |
| Connector | Approx. 40 g (M8/M12 Connector) | Approx. 55 g | Approx. 85 g | Approx. 160 g | |
| Materials | Case | Stainless (SUS303) | Nickel-plated brass | ||
| Sensing surface | Polybutylene terephthalat (PBT) | ||||
| Clamping nuts | Nickel-plated brass | ||||
| Toothed washers | Zinc-plated iron | ||||
| Cable | Vinyl chloride (PVC) Note: Material of Pre-wired Models and Pre-wired Connector Models. | ||||
| Main IO-Link functions *2 | Operation mode switching between NO and NC, self diagnosis enabling, excessive proximity judgment distance selecting, timer function of the control output and timer time selecting, instability output (IO-Link mode) ON delay timer time selecting function, monitor output, operating hours read-out, readout of the sensor internal temperature, and initial reset | ||||
| IO-Link Commun- ication specifica- tions *2 | IO-Link specification | Ver 1.1 | |||
| Baud rate | COM2 (38.4 kbps), COM3 (230.4 kbps) | ||||
| Data length | PD size: 2 bytes, OD size: 1 byte (M-sequence type: TYPE_2_2) | ||||
| Minimum cycle time | COM2: 2.3 ms, COM3: 0.4 ms | ||||
| Accessories | Instruction manual, Clamping nuts, Toothed washer | ||||
| Size | M8 | M12 | |||
|---|---|---|---|---|---|
| Shielded | Shielded | Unshielded | Shielded | Unshielded | |
| Model | E2E-X3D[] | E2E-X6MD[] | E2E-X7D[] | E2E-X10MD[] | |
| Sensing distance | 3 mm ±10% | 6 mm ±10% | 7 mm ±10% | 10 mm ±10% | |
| Setting distance *1 | 0 to 2.4 mm | 0 to 4.8 mm | 0 to 5.6 mm | 0 to 8 mm | |
| Differential travel | 15% max. of sensing distance | ||||
| Detectable object | Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on Catalog.) | ||||
| Standard sensing object | Iron, 9 × 9 × 1 mm | Iron, 18 × 18 × 1 mm | Iron, 21 × 21 × 1 mm | Iron, 30 × 30 × 1 mm | |
| Response frequency *2 | 350 Hz | 250 Hz | 350 Hz | 200 Hz | |
| Power supply voltage | 10 to 30 VDC, (including 10% ripple (p-p)) | ||||
| Leakage current | 0.8 mA max. | ||||
| Control output | Load current | 3 to 100 mA | |||
| Residual voltage | Polarity: 3 V max. (Load current: 100 mA, Cable length: 2 m) No polarity: 5 V max. (Load current: 100 mA, Cable length: 2 m) | ||||
| Indicator | D1 Models: Operation indicator (orange), Setting indicator (green) D2 Models: Operation indicator (orange) | ||||
| Operation mode | D1 Models: NO D2 Models: NC Refer to the timing charts under I/O Circuit Diagrams on Catalog for details. | ||||
| Protection circuits | Surge suppressor, Load short-circuit protection | ||||
| Ambient temperature range | Operating: -25 to 70°C, Storage: -40 to 85°C (with no icing or condensation) | ||||
| Ambient humidity range | Operating and Storage: 35% to 95% (with no condensation) | ||||
| Temperature influence | ±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C | ||||
| Voltage influence | ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range | ||||
| Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | ||||
| Dielectric strength | 1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case | ||||
| Vibration resistance (destruction) | 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | ||||
| Shock resistance (destruction) | 500 m/s2 10 times each in X, Y, and Z directions | 1,000 m/s2 10 times each in X, Y, and Z directions | |||
| Degree of protection | Pre-wired Models/Pre-wired Connector Models: IP67 (IEC 60529), IP67G *3 (JIS C 0920 Annex 1) Passed OMRON's Oil-resistant Component Evaluation Standards *4 (Cutting oil type: specified in JIS K 2241:2000, Temperature: 35 °C max.) and ISO 20653 (old standard: DIN 40050 PART9) IP69K | ||||
| Connecting method | Pre-wired Models (Standard cable length: 2 m) and Pre-wired Connector Models (Standard cable length: 0.3 m) | ||||
| Weight (packed state) | Pre-wired Models | Approx. 60 g | Approx. 70 g | ||
| Pre-wired Connector Models | Approx. 30 g | Approx. 40 g | |||
| Materials | Case | Nickel-plated brass | Stainless steel (SUS303) | Nickel-plated brass | |
| Sensing surface | Polybutylene terephthalate (PBT) | ||||
| Clamping nuts | Nickel-plated brass | ||||
| Toothed washer | Zinc-plated iron | ||||
| Cable | Vinyl chloride (PVC) | ||||
| Accessories | Instruction manual, Clamping nuts, Toothed washer | ||||
| Size | M18 | M30 | |||
|---|---|---|---|---|---|
| Shielded | Shielded | Unshielded | Shielded | Unshielded | |
| Model | E2E-X11D[] | E2E-X20MD[] | E2E-X20D[] | E2E-X40MD[] | |
| Sensing distance | 11 mm ±10% | 20 mm ±10% | 20 mm ±10% | 40 mm ±10% | |
| Setting distance *1 | 0 to 8.8 mm | 0 to 16 mm | 0 to 16 mm | 0 to 32 mm | |
| Differential travel | 15% max. of sensing distance | ||||
| Detectable object | Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on Catalog.) | ||||
| Standard sensing object | Iron, 33 × 33 × 1 mm | Iron, 60 × 60 × 1 mm | Iron, 60 × 60 × 1 mm | Iron, 120 × 120 × 1 mm | |
| Response frequency *2 | 250 Hz | 200 Hz | 200 Hz | 50 Hz | |
| Power supply voltage | 10 to 30 VDC, (including 10% ripple (p-p)) | ||||
| Leakage current | 0.8 mA max. | ||||
| Control output | Load current | 3 to 100 mA | |||
| Residual voltage | Polarity: 3 V max. (Load current: 100 mA, Cable length: 2 m) No polarity: 5 V max. (Load current: 100 mA, Cable length: 2 m) | ||||
| Indicator | D1 Models: Operation indicator (orange), Setting indicator (green) D2 Models: Operation indicator (orange) | ||||
| Operation mode | D1 Models: NO D2 Models: NC Refer to the timing charts under I/O Circuit Diagrams on Catalog for details. | ||||
| Protection circuits | Surge suppressor, Load short-circuit protection | ||||
| Ambient temperature range | Operating: -25 to 70°C, Storage: -40 to 85°C (with no icing or condensation) | ||||
| Ambient humidity range | Operating and Storage: 35% to 95% (with no condensation) | ||||
| Temperature influence | ±20% max. of sensing distance at 23°C in the temperature range of -25 to 70°C | ±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C | ±20% max. of sensing distance at 23°C in the temperature range of -25 to 70°C | ||
| Voltage influence | ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range | ||||
| Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | ||||
| Dielectric strength | 1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case | ||||
| Vibration resistance (destruction) | 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | ||||
| Shock resistance (destruction) | 1,000 m/s2 10 times each in X, Y, and Z directions | ||||
| Degree of protection | Pre-wired Models/Pre-wired Connector Models: IP67 (IEC 60529), IP67G *3 (JIS C 0920 Annex 1) Passed OMRON's Oil-resistant Component Evaluation Standards *4 (Cutting oil type: specified in JIS K 2241:2000, Temperature: 35 °C max.) and ISO 20653 (old standard: DIN 40050 PART9) IP69K | ||||
| Connecting method | Pre-wired Models (Standard cable length: 2 m) and Pre-wired Connector Models (Standard cable length: 0.3 m) | ||||
| Weight (packed state) | Pre-wired Models | Approx. 130 g | Approx. 150 g | Approx. 180 g | Approx. 210 g | 
| Pre-wired Connector Models | Approx. 70 g | Approx. 90 g | Approx.110 g | Approx. 140 g | |
| Materials | Case | Nickel-plated brass | |||
| Sensing surface | Polybutylene terephthalate (PBT) | ||||
| Clamping nuts | Nickel-plated brass | ||||
| Toothed washer | Zinc-plated iron | ||||
| Cable | Vinyl chloride (PVC) | ||||
| Accessories | Instruction manual, Clamping nuts, Toothed washer | ||||
| Size | M8 | M12 | |||
|---|---|---|---|---|---|
| Shielded | Shielded | Unshielded | Shielded | Unshielded | |
| Item Model | E2E-X2D[] | E2E-X4MD[] | E2E-X3D[] | E2E-X8MD[] | |
| Sensing distance | 2 mm ±10% | 4 mm ±10% | 3 mm ±10% | 8 mm ±10% | |
| Setting distance *1 | 0 to 1.6 mm | 0 to 3.2 mm | 0 to 2.4 mm | 0 to 6.4 mm | |
| Differential travel | 15% max. of sensing distance | 10% max. of sensing distance | |||
| Detectable object | Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on Catalog.) | ||||
| Standard sensing object | Iron, 8 × 8 × 1 mm | Iron, 20 × 20 × 1 mm | Iron, 12 × 12 × 1 mm | Iron, 30 × 30 × 1 mm | |
| Response frequency *2 | 1.5 kHz | 1 kHz | 1 kHz | 0.8 kHz | |
| Power supply voltage | 12 to 24 VDC (including 10% ripple (p-p)), Class 2 | ||||
| Leakage current | 0.8 mA max. | ||||
| Control output | Load current | 3 to 100 mA | |||
| Residual voltage | Polarity: 3 V max. (Load current: 100 mA, Cable length: 2 m) No polarity: 5 V max. (Load current: 100 mA, Cable length: 2 m) | ||||
| Indicator | D1 Models: Operation indicator (orange), Setting indicator (green) D2 Models: Operation indicator (orange) | ||||
| Operation mode | D1 Models: NO D2 Models: NC Refer to the timing charts under I/O Circuit Diagrams on Catalog for details. | ||||
| Protection circuits | Surge suppressor, Load short-circuit protection | ||||
| Ambient temperature range | Operating: -25 to 70°C, Storage: -40 to 85°C (with no icing or condensation) | ||||
| Ambient humidity range | Operating and Storage: 35% to 95% (with no condensation) | ||||
| Temperature influence | ±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C | ||||
| Voltage influence | ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range | ||||
| Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | ||||
| Dielectric strength | 1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case | ||||
| Vibration resistance (destruction) | 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | ||||
| Shock resistance (destruction) | 500 m/s2 10 times each in X, Y, and Z directions | 1,000 m/s2 10 times each in X, Y, and Z directions | |||
| Degree of protection | Pre-wired Models/Pre-wired Connector Models: IP67 (IEC 60529), IP67G *3 (JIS C 0920 Annex 1) Passed OMRON's Oil-resistant Component Evaluation Standards *4 (Cutting oil type: specified in JIS K 2241:2000, Temperature: 35°C max.) and ISO 20653 (old standard: DIN 40050 PART9) IP69K | ||||
| Connecting method | Pre-wired Models (Standard cable length: 2 m), Pre-wired Connector Models (Standard cable length: 0.3 m), M8 Connector Models and M12 Connector Models | ||||
| Weight *5 (packed state) | Pre-wired Models | Approx. 60 g | Approx. 70 g | ||
| Pre-wired Connector Models | Approx. 30 g | Approx. 40 g | |||
| Connector Models | Approx. 40 g (M8/M12 Connector) | Approx. 55 g | |||
| Materials | Case | M8 Size: Stainless steel (SUS303), M12/M18/M30 Size: Nickel-plated brass | |||
| Sensing surface | Polybutylene terephthalate (PBT) | ||||
| Clamping nuts | Nickel-plated brass | ||||
| Toothed washer | Zinc-plated iron | ||||
| Cable | Vinyl chloride (PVC) Note: Material of Pre-wired Models and Pre-wired Connector Models. | ||||
| Accessories | Instruction manual, Clamping nuts, Toothed washer | ||||
| Size | M18 | M30 | |||
|---|---|---|---|---|---|
| Shielded | Shielded | Unshielded | Shielded | Unshielded | |
| Item Model | E2E-X7D[] | E2E-X14MD[] | E2E-X10D[] | E2E-X20MD[] | |
| Sensing distance | 7 mm ±10% | 14 mm ±10% | 10 mm ±10% | 20 mm ±10% | |
| Setting distance *1 | 0 to 5.6 mm | 0 to 11.2 mm | 0 to 8 mm | 0 to 16 mm | |
| Differential travel | 15% max. of sensing distance | 10% max. of sensing distance | |||
| Detectable object | Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on Catalog.) | ||||
| Standard sensing object | Iron, 18 × 18 × 1 mm | Iron, 30 × 30 × 1 mm | Iron, 30 × 30 × 1 mm | Iron, 54 × 54 × 1 mm | |
| Response frequency *2 | 0.5 kHz | 0.4 kHz | 0.4 kHz | 0.1 kHz | |
| Power supply voltage | 12 to 24 VDC (including 10% ripple (p-p)), Class 2 | ||||
| Leakage current | 0.8 mA max. | ||||
| Control output | Load current | 3 to 100 mA | |||
| Residual voltage | Polarity: 3 V max. (Load current: 100 mA, Cable length: 2 m) No polarity: 5 V max. (Load current: 100 mA, Cable length: 2 m) | ||||
| Indicator | D1 Models: Operation indicator (orange), Setting indicator (green) D2 Models: Operation indicator (orange) | ||||
| Operation mode | D1 Models: NO D2 Models: NC Refer to the timing charts under I/O Circuit Diagrams on Catalog for details. | ||||
| Protection circuits | Surge suppressor, Load short-circuit protection | ||||
| Ambient temperature range | Operating: -25 to 70°C, Storage: -40 to 85°C (with no icing or condensation) | ||||
| Ambient humidity range | Operating and Storage: 35% to 95% (with no condensation) | ||||
| Temperature influence | ±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C | ||||
| Voltage influence | ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range | ||||
| Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | ||||
| Dielectric strength | 1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case | ||||
| Vibration resistance (destruction) | 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | ||||
| Shock resistance (destruction) | 1,000 m/s2 10 times each in X, Y, and Z directions | ||||
| Degree of protection | Pre-wired Models/Pre-wired Connector Models: IP67 (IEC 60529), IP67G *3 (JIS C 0920 Annex 1) Passed OMRON's Oil-resistant Component Evaluation Standards *4 (Cutting oil type: specified in JIS K 2241:2000, Temperature: 35°C max.) and ISO 20653 (old standard: DIN 40050 PART9) IP69K | ||||
| Connecting method | Pre-wired Models (Standard cable length: 2 m), Pre-wired Connector Models (Standard cable length: 0.3 m), M8 Connector Models and M12 Connector Models | ||||
| Weight *5 (packed state) | Pre-wired Models | Approx. 130 g | Approx. 150 g | Approx. 180 g | Approx. 210 g | 
| Pre-wired Connector Models | Approx. 70 g | Approx. 90 g | Approx. 110 g | Approx. 140 g | |
| Connector Models | Approx. 85 g | Approx. 80 g | Approx. 160 g | Approx. 150 g | |
| Materials | Case | M8 Size: Stainless steel (SUS303), M12/M18/M30 Size: Nickel-plated brass | |||
| Sensing surface | Polybutylene terephthalate (PBT) | ||||
| Clamping nuts | Nickel-plated brass | ||||
| Toothed washer | Zinc-plated iron | ||||
| Cable | Vinyl chloride (PVC) Note: Material of Pre-wired Models and Pre-wired Connector Models. | ||||
| Accessories | Instruction manual, Clamping nuts, Toothed washer | ||||
| Size | M12 | M18 | M30 | |||
|---|---|---|---|---|---|---|
| Shielded | Shielded | Unshielded | Shielded | Shielded | Unshielded | |
| Item Model | E2E-X4D[] | E2E-X8D[] | E2E-X16MD[] | E2E-X15D[] | E2E-X30MD[] | |
| Sensing distance | 4 mm ±10% | 8 mm ±10% | 16 mm ±10% | 15 mm ±10% | 30 mm ±10% | |
| Setting distance *1 | 0 to 3.2 mm | 0 to 6.4 mm | 0 to 12.8 mm | 0 to 12 mm | 0 to 24 mm | |
| Differential travel | 15% max. of sensing distance | |||||
| Detectable object | Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on Catalog.) | |||||
| Standard sensing object | Iron, 12 × 12 × 1 mm | Iron, 18 × 18 × 1 mm | Iron, 45 × 45 × 1 mm | Iron, 30 × 30 × 1 mm | Iron, 70 × 70 × 1 mm | |
| Response frequency *2 | 1 kHz | 0.5 kHz | 0.4 kHz | 0.25 kHz | 0.1 kHz | |
| Power supply voltage | 12 to 24 VDC (including 10% ripple (p-p)), Class 2 | |||||
| Leakage current | 0.8 mA max. | |||||
| Control output | Load current | 3 to 100 mA | ||||
| Residual voltage | 5 V max. (Load current: 100 mA, Cable length: 2 m) | |||||
| Indicator | D1 Models: Operation indicator (orange), Setting indicator (green) D2 Models: Operation indicator (orange) | |||||
| Operation mode | D1 Models: NO D2 Models: NC Refer to the timing charts under I/O Circuit Diagrams on Catalog for details. | |||||
| Protection circuits | Surge suppressor, Load short-circuit protection | |||||
| Ambient temperature range | Operating: -25 to 70°C, Storage: -40 to 85°C (with no icing or condensation) | |||||
| Ambient humidity range | Operating and Storage: 35% to 95% (with no condensation) | |||||
| Temperature influence | ±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C | |||||
| Voltage influence | ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range | |||||
| Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | |||||
| Dielectric strength | 1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case | |||||
| Vibration resistance (destruction) | 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | |||||
| Shock resistance (destruction) | 500 m/s2 10 times each in X, Y, and Z directions | 1,000 m/s2 10 times each in X, Y, and Z directions | ||||
| Degree of protection | Pre-wired Models/Pre-wired Connector Models: IP67 (IEC 60529), IP67G *3 (JIS C 0920 Annex 1) Passed OMRON's Oil-resistant Component Evaluation Standards *4 (Cutting oil type: specified in JIS K 2241:2000, Temperature: 35°C max.) and ISO 20653 (old standard: DIN 40050 PART9) IP69K | |||||
| Connecting method | Pre-wired Models (Standard cable length: 2 m), Pre-wired Connector Models (Standard cable length: 0.3 m) | |||||
| Weight (packed state) | Pre-wired Models | Approx. 70 g | Approx. 130 g | Approx. 150 g | Approx. 180 g | Approx. 210 g | 
| Pre-wired Connector Models | Approx. 40 g | Approx. 70 g | Approx. 90 g | Approx. 110 g | Approx. 140 g | |
| Materials | Case | Nickel-plated brass | ||||
| Sensing surface | Polybutylene terephthalate (PBT) | |||||
| Clamping nuts | Nickel-plated brass | |||||
| Toothed washer | Zinc-plated iron | |||||
| Cable | Vinyl chloride (PVC) | |||||
| Accessories | Instruction manual, Clamping nuts, Toothed washer | |||||
| Size | M8 | M12 | M18 | |
|---|---|---|---|---|
| Shielded | Shielded | |||
| Model | E2E-X1R5D[] | E2E-X2R5D[] | E2E-X5D[] | |
| Sensing distance | 1.5 mm ±10% | 2.5 mm ±10% | 5 mm ±10% | |
| Setting distance *1 | 0 to 1.2 mm | 0 to 2 mm | 0 to 4 mm | |
| Differential travel | 10% max. of sensing distance | |||
| Detectable object | Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on Catalog.) | |||
| Standard sensing object | Iron, 10 × 10 × 1 mm | Iron, 12 × 12 × 1 mm | Iron, 18 × 18 × 1 mm | |
| Response frequency *2 | 250 Hz | 250 Hz | 250 Hz | |
| Power supply voltage | 10 to 30 VDC, (including 10% ripple (p-p)) | |||
| Leakage current | 0.8 mA max. | |||
| Control output | Load current | 3 to 100 mA | ||
| Residual voltage | Polarity: 3 V max. (Load current: 100 mA, Cable length: 2 m) No polarity: 5 V max. (Load current: 100 mA, Cable length: 2 m) | |||
| Indicator | D1 Models: Operation indicator (orange), Setting indicator (green) D2 Models: Operation indicator (orange) | |||
| Operation mode | D1 Models: NO D2 Models: NC Refer to the timing charts under I/O Circuit Diagrams on Catalog for details. | |||
| Protection circuits | Surge suppressor, Load short-circuit protection | |||
| Ambient temperature range | Operating: -25 to 70°C, Storage: -40 to 85°C (with no icing or condensation) | |||
| Ambient humidity range | Operating and Storage: 35% to 95% (with no condensation) | |||
| Temperature influence | ±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C | |||
| Voltage influence | ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range | |||
| Insulation resistance | 50 MΩ min. (at 500 VDC) between current-carrying parts and case | |||
| Dielectric strength | 1,000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case | |||
| Vibration resistance (destruction) | 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | |||
| Shock resistance (destruction) | 500 m/s2 10 times each in X, Y, and Z directions | 1,000 m/s2 10 times each in X, Y, and Z directions | ||
| Degree of protection | Pre-wired Models/Pre-wired Connector Models: IP67 (IEC 60529), IP67G *3 (JIS C 0920 Annex 1) Passed OMRON's Oil-resistant Component Evaluation Standards *4 (Cutting oil type: specified in JIS K 2241:2000, Temperature: 35°C max.) and ISO 20653 (old standard: DIN 40050 PART9) IP69K | |||
| Connecting method | Pre-wired Models (Standard cable length: 2 m) and Pre-wired Connector Models (Standard cable length: 0.3 m) | |||
| Weight (packed state) | Pre-wired Models | Approx. 60 g | Approx. 70 g | Approx. 130 g | 
| Pre-wired Connector Models | Approx. 30 g | Approx. 40 g | Approx. 70 g | |
| Materials | Case | Stainless steel (SUS303) | Nickel-plated brass | |
| Sensing surface | Polybutylene terephthalate (PBT) | |||
| Clamping nuts | Nickel-plated brass | |||
| Toothed washer | Zinc-plated iron | |||
| Cable | Vinyl chloride (PVC) | |||
| Accessories | Instruction manual, Clamping nuts, Toothed washer | |||
last update: October 2, 2023