Photoelectric Sensors
last update: January 27, 2025
Sensing method | Through-beam | Retro-reflective
with MSR function |
Coaxial Retro-
reflective with MSR function |
|||
---|---|---|---|---|---|---|
Model | NPN
output |
Pre-wired | E3F[]-TN11 2M | E3FA-TN12 2M | E3F[]-RN11 2M | E3F[]-RN12 2M |
M12
Connector |
E3F[]-TN21 | E3FA-TN22 | E3F[]-RN21 | E3F[]-RN22 | ||
PNP
output |
Pre-wired | E3F[]-TP11 2M | E3FA-TP12 2M | E3F[]-RP11 2M | E3F[]-RP12 2M | |
M12
Connector |
E3F[]-TP21 | E3FA-TP22 | E3F[]-RP21 | E3F[]-RP22 | ||
Sensing distance | 20 m | 15 m | 0.1 to 4 m
(with E39-R1S) |
0 to 500 mm
(with E39-R1S) |
||
Spot diameter (reference
value) |
— | |||||
Standard sensing object | Opaque: 7 mm dia.min. | Opaque: 75 mm dia.min. | ||||
Differential travel | — | |||||
Directional angle | 2° min. | |||||
Light source (wavelength) | Red LED (624 nm) | Infrared LED
(850 nm) |
Red LED (624 nm) | |||
Power supply voltage | 10 to 30 VDC (include voltage ripple of 10%(p-p) max.) | |||||
Current consumption | 40 mA max.
(Emitter 25 mA max. Receiver 15 mA max.) |
25 mA max. | ||||
Control output | NPN/PNP (open collector)
Load current: 100 mA max. (Residual voltage: 3 V max.), Load power supply voltage: 30 VDC max. |
|||||
Operation mode | Light-ON/Dark-ON selectable by wiring | |||||
Indicator | Operation indicator (orange)
Stability indicator (green) Power indicator (green): only Emitter of Through-beam |
|||||
Protection circuits | Power supply reverse polarity protection, Output short-circuit protection, and
Output reverse polarity protection |
|||||
Response time | 0.5 ms | |||||
Sensitivity adjustment | One-turn adjuster | |||||
Ambient illumination
(Receiver side) |
Incandescent lamp: 3,000 lx max./Sunlight: 10,000 lx max. | |||||
Ambient temperature range | Pre-wired Models
Operating: -25 to 55°C/Storage: -40 to 70°C (with no icing or condensation) M12 Connector Models Operating: -40 to 55°C/Storage: -40 to 70°C (with no icing or condensation) |
|||||
Ambient humidity range | Operating: 35 to 85%/Storage: 35 to 95% (with no condensation) | |||||
Insulation resistance | 20 MΩ min. at 500 VDC | |||||
Dielectric strength | 1,000 VAC at 50/60 Hz for 1 min. between current-carrying parts and case | |||||
Vibration resistance | Destruction: 10 to 55 Hz, 1.5 mm double amplitude for 2 hours each in X, Y and Z
directions |
|||||
Shock resistance | Destruction: 500 m/s2 3 times each in X, Y and Z directions | |||||
Degree of protection | IEC: IP67, DIN 40050-9: IP69K * | |||||
Weight
(packed state/ only sensor) |
Pre-wired cable
(2M) |
E3FA: Approx. 110 g/Approx. 50 g,
respectively, E3FB: Approx. 175 g/Approx. 65 g, respectively |
E3FA: Approx. 60 g/Approx. 50 g,
E3FB: Approx. 95 g/Approx. 65 g |
|||
Connector | E3FA: Approx. 30 g/Approx. 10 g,
respectively, E3FB: Approx. 85 g/Approx. 20 g, respectively |
E3FA: Approx. 20 g/Approx. 10 g,
E3FB: Approx. 50 g/Approx. 20 g |
||||
Material | Case | E3FA: ABS, E3FB: Nickel-brass | ||||
Lens and Display | PMMA | |||||
Adjuster | POM | |||||
Nut | E3FA: POM, E3FB: Nickel-brass | |||||
Accessories | Instruction sheet
M18 nuts (4 pcs) |
Instruction sheet
M18 nuts (2 pcs) |
* IP69K Degree of Protection Specifications
IP69K is a protection specification stipulated by DIN 40050 Part 9 of the German standards.
The test item is sprayed with 80°C water from a nozzle of a specified shape at a water pressure of 80 to 100 bar. The amount of water is 14 to 16 liters per minute.
The distance between the test item and the nozzle is 10 to 15 cm. The water is discharged at angles of 0°, 30°, 60°, and 90° from the horizontal plane for 30 seconds at each angle while the test item is rotated horizontally.
Sensing method | Diffuse-reflective | |||||||
---|---|---|---|---|---|---|---|---|
Model | NPN
output |
Pre-wired | E3F[]-
DN11 2M |
E3F[]-
DN12 2M |
E3F[]-
DN13 2M |
E3FA-
DN14 2M |
E3FA-
DN15 2M |
E3FA-
DN16 2M |
M12
Connector |
E3F[]-
DN21 |
E3F[]-
DN22 |
E3F[]-
DN23 |
E3FA-
DN24 |
E3FA-
DN25 |
E3FA-
DN26 |
||
PNP
output |
Pre-wired | E3F[]-
DP11 2M |
E3F[]-
DP12 2M |
E3F[]-
DP13 2M |
E3FA-
DP14 2M |
E3FA-
DP15 2M |
E3FA-
DP16 2M |
|
M12
Connector |
E3F[]-
DP21 |
E3F[]-
DP22 |
E3F[]-
DP23 |
E3FA-
DP24 |
E3FA-
DP25 |
E3FA-
DP26 |
||
Sensing distance | 100 mm
(white paper: 300 × 300 mm) |
300 mm
(white paper: 300 × 300 mm) |
1 m
(white paper: 300 × 300 mm) |
100 mm
white paper: 300 × 300 mm) |
300 mm
(white paper: 300 × 300 mm) |
1 m
(white paper: 300 × 300 mm) |
||
Spot diameter
(reference value) |
40 × 45 mm
Sensing distance of 100 mm |
40 × 50 mm
Sensing distance of 300 mm |
120 × 150
mm Sensing distance of 1 m |
40 × 45 mm
Sensing distance of 100 mm |
40 × 50 mm
Sensing distance of 300 mm |
120 × 150
mm Sensing distance of 1 m |
||
Standard sensing object | -- | |||||||
Differential travel | 20% max. | |||||||
Directional angle | -- | |||||||
Light source (wavelength) | Red LED (624 nm) | Infrared LED (850 nm) | ||||||
Power supply voltage | 10 to 30 VDC (include voltage ripple of 10%(p-p) max.) | |||||||
Current consumption | 25 mA max. | |||||||
Control output | NPN/PNP (open collector)
Load current: 100 mA max. (Residual voltage: 3 V max.), Load power supply voltage: 30 VDC max. |
|||||||
Operation mode | Light-ON/Dark-ON selectable by wiring | |||||||
Indicator | Operation indicator (orange)
Stability indicator (green) |
|||||||
Protection circuits | Power supply reverse polarity protection, Output short-circuit protection, and Output
reverse polarity protection |
|||||||
Response time | 0.5 ms | |||||||
Sensitivity adjustment | One-turn adjuster | |||||||
Ambient illumination
(Receiver side) |
Incandescent lamp: 3,000 lx max./Sunlight: 10,000 lx max. | |||||||
Ambient temperature range | Pre-wired Models
Operating: -25 to 55°C/Storage: -40 to 70°C (with no icing or condensation) M12 Connector Models Operating: -40 to 55°C/Storage: -40 to 70°C (with no icing or condensation) |
|||||||
Ambient humidity range | Operating: 35 to 85%/Storage: 35 to 95% (with no condensation) | |||||||
Insulation resistance | 20 MΩ min. at 500 VDC | |||||||
Dielectric strength | 1,000 VAC at 50/60 Hz for 1 min. between current-carrying parts and case | |||||||
Vibration resistance | Destruction: 10 to 55 Hz, 1.5 mm double amplitude for 2 hours each in X, Y and Z
directions |
|||||||
Shock resistance | Destruction: 500 m/s2 3 times each in X, Y and Z directions | |||||||
Degree of protection | IEC: IP67, DIN 40050-9: IP69K * | |||||||
Weight
(packed state/ only sensor) |
Pre-wired cable
(2M) |
E3FA: Approx. 60 g/Approx. 50 g,
E3FB: Approx. 95 g/Approx. 65 g |
||||||
Connector | E3FA: Approx. 20 g/Approx. 10 g,
E3FB: Approx. 50 g/Approx. 20 g |
|||||||
Material | Case | E3FA: ABS, E3FB: Nickel-brass | ||||||
Lens and Display | PMMA | |||||||
Adjuster | POM | |||||||
Nut | E3FA: POM, E3FB: Nickel-brass | |||||||
Accessories | Instruction sheet
M18 nuts (2 pcs) |
* IP69K Degree of Protection Specifications
IP69K is a protection specification stipulated by DIN 40050 Part 9 of the German standards.
The test item is sprayed with 80°C water from a nozzle of a specified shape at a water pressure of 80 to 100 bar. The amount of water is 14 to 16 liters per minute.
The distance between the test item and the nozzle is 10 to 15 cm. The water is discharged at angles of 0°, 30°, 60°, and 90° from the horizontal plane for 30 seconds at each angle while the test item is rotated horizontally.
Sensing method | BGS
(Background suppression) |
Limited
distance reflective |
Transparent detected with
P-opaquing function |
||||
---|---|---|---|---|---|---|---|
Model | NPN
output |
Pre-wired | E3F[]-LN11
2M |
E3F[]-LN12
2M |
E3F[]-VN11
2M |
E3F[]-BN11
2M |
E3F[]-BN12
2M |
M12
Connector |
E3F[]-LN21 | E3F[]-LN22 | E3F[]-VN21 | E3F[]-BN21 | E3F[]-BN22 | ||
PNP
output |
Pre-wired | E3F[]-LP11
2M |
E3F[]-LP12
2M |
E3F[]-VP11
2M |
E3F[]-BP11
2M |
E3F[]-BP12
2M |
|
M12
Connector |
E3F[]-LP21 | E3F[]-LP22 | E3F[]-VP21 | E3F[]-BP21 | E3F[]-BP22 | ||
Sensing distance | 100 mm
(white paper: 300 × 300 mm) |
200 mm
(white paper: 300 × 300 mm) |
10 to 50 mm
(glass (t = 1.0 mm): 150 × 150 mm) |
100 to 500 mm
(with E39-RP1) |
0.1 to 2 m
(with E39-RP1) |
||
Spot diameter
(reference value) |
10 × 10 mm
Sensing distance of 100 mm |
10 × 15 mm
Sensing distance of 200 mm |
10 × 10 mm
Sensing distance of 50 mm |
-- | |||
Standard sensing object | -- | glass(t = 1.0 mm): 150 × 150 mm | |||||
Differential travel | 20% max. | -- | |||||
Directional angle | -- | ||||||
Light source (wavelength) | Red LED (624 nm) | ||||||
Power supply voltage | 10 to 30 VDC (include voltage ripple of 10%(p-p) max.) | ||||||
Current consumption | 25 mA max. | ||||||
Control output | NPN/PNP (open collector)
Load current: 100 mA max. (Residual voltage: 3 V max.), Load power supply voltage: 30 VDC max. |
||||||
Operation mode | Light-ON/Dark-ON selectable by wiring | ||||||
Indicator | Operation indicator (orange)
Stability indicator (green) Power indicator (green): only Emitter of Through-beam |
||||||
Protection circuits | Power supply reverse polarity protection, Output short-circuit protection, and Output
reverse polarity protection |
||||||
Response time | 0.5 ms | ||||||
Sensitivity adjustment | Fixed | One-turn adjuster | |||||
Ambient illumination
(Receiver side) |
Incandescent lamp: 3,000 lx max./Sunlight: 10,000 lx max. | ||||||
Ambient temperature range | Pre-wired Models
Operating: -25 to 55°C/Storage: -40 to 70°C (with no icing or condensation) M12 Connector Models Operating: -40 to 55°C/Storage: -40 to 70°C (with no icing or condensation) |
||||||
Ambient humidity range | Operating: 35 to 85%/Storage: 35 to 95% (with no condensation) | ||||||
Insulation resistance | 20 MΩ min. at 500 VDC | ||||||
Dielectric strength | 1,000 VAC at 50/60 Hz for 1 min. between current-carrying parts and case | ||||||
Vibration resistance | Destruction: 10 to 55 Hz, 1.5 mm double amplitude for 2 hours each in X, Y and Z
directions |
||||||
Shock resistance | Destruction: 500 m/s2 3 times each in X, Y and Z directions | ||||||
Degree of protection | IEC: IP67, DIN 40050-9: IP69K * | ||||||
Weight
(packed state/ only sensor) |
Pre-wired cable
(2M) |
E3FA: Approx. 60 g/Approx. 50 g,
E3FB: Approx. 95 g/Approx. 65 g |
|||||
Connector | E3FA: Approx. 20 g/Approx. 10 g,
E3FB: Approx. 50 g/Approx. 20 g |
||||||
Material | Case | E3FA: ABS, E3FB: Nickel-brass | |||||
Lens and Display | PMMA | ||||||
Adjuster | POM | ||||||
Nut | E3FA: POM, E3FB: Nickel-brass | ||||||
Accessories | Instruction sheet
M18 nuts (2 pcs) |
* IP69K Degree of Protection Specifications
IP69K is a protection specification stipulated by DIN 40050 Part 9 of the German standards.
The test item is sprayed with 80°C water from a nozzle of a specified shape at a water pressure of 80 to 100 bar. The amount of water is 14 to 16 liters per minute.
The distance between the test item and the nozzle is 10 to 15 cm. The water is discharged at angles of 0°, 30°, 60°, and 90° from the horizontal plane for 30 seconds at each angle while the test item is rotated horizontally.
Sensing method | Through-
beam |
Retro-
reflective with MSR function |
Diffuse-reflective | ||||
---|---|---|---|---|---|---|---|
Model | NPN
output |
Pre-wired | E3R[]-TN11
2M |
E3R[]-RN11
2M |
E3R[]-DN11
2M |
E3R[]-DN12
2M |
E3R[]-DN13
2M |
M12
Connector |
E3R[]-TN21 | E3R[]-RN21 | E3R[]-DN21 | E3R[]-DN22 | E3R[]-DN23 | ||
PNP
output |
Pre-wired | E3R[]-TP11
2M |
E3R[]-RP11
2M |
E3R[]-DP11
2M |
E3R[]-DP12
2M |
E3R[]-DP13
2M |
|
M12
Connector |
E3R[]-TP21 | E3R[]-RP21 | E3R[]-DP21 | E3R[]-DP22 | E3R[]-DP23 | ||
Sensing distance | 15 m | 0.1 to 3 m
(with E39-R1S) |
100 mm
(white paper: 300 × 300 mm) |
300 mm
(white paper: 300 × 300 mm) |
700 mm
(white paper: 300 × 300 mm) |
||
Spot diameter
(reference value) |
-- | 35 × 40 mm
Sensing distance of 100 mm |
40 × 45 mm
Sensing distance of 300 mm |
90 × 120 mm
Sensing distance of 700 mm |
|||
Standard sensing object | Opaque:
7 mm dia. min. |
Opaque:
75 mm dia. min. |
-- | ||||
Differential travel | -- | 20% max. | |||||
Directional angle | 2° min. | -- | |||||
Light source (wavelength) | Red LED (624 nm) | ||||||
Power supply voltage | 10 to 30 VDC (include voltage ripple of 10%(p-p) max.) | ||||||
Current consumption | 40mA max.
(Emitter 25 mA max. Receiver 15 mA max.) |
25 mA max. | |||||
Control output | NPN/PNP (open collector)
Load current: 100 mA max. (Residual voltage: 2 V max.), Load power supply voltage: 30 VDC max. |
||||||
Operation mode | Light-ON/Dark-ON selectable by wiring | ||||||
Indicator | Operation indicator (orange)
Stability indicator (green) Power indicator (green): only Emitter of Through-beam |
||||||
Protection circuits | Power supply reverse polarity protection, Output short-circuit protection, and Output
reverse polarity protection |
||||||
Response time | 0.5 ms | ||||||
Sensitivity adjustment | One-turn adjuster | ||||||
Ambient illumination
(Receiver side) |
Incandescent lamp: 3,000 lx max./Sunlight: 10,000 lx max. | ||||||
Ambient temperature range | Pre-wired Models
Operating: -25 to 55°C/Storage: -40 to 70°C (with no icing or condensation) M12 Connector Models Operating: -40 to 55°C/Storage: -40 to 70°C (with no icing or condensation) |
||||||
Ambient humidity range | Operating: 35 to 85%/Storage: 35 to 95% (with no condensation) | ||||||
Insulation resistance | 20 MΩ min. at 500 VDC | ||||||
Dielectric strength | 1,000 VAC at 50/60 Hz for 1 min. between current-carrying parts and case | ||||||
Vibration resistance | Destruction: 10 to 55 Hz, 1.5 mm double amplitude for 2 hours each in X, Y and Z
directions |
||||||
Shock resistance | Destruction: 500 m/s2 3 times each in X, Y and Z directions | ||||||
Degree of protection | IEC: IP67, DIN 40050-9: IP69K * | ||||||
Weight
(packed state/ only sensor) |
Pre-wired cable
(2M) |
E3RA:
Approx. 110 g/ Approx. 50 g, respectively, E3RB: Approx. 175 g/ Approx. 65 g, respectively |
E3RA: Approx. 60 g/Approx. 50 g,
E3RB: Approx. 95 g/Approx. 65 g |
||||
Connector | E3RA:
Approx. 30 g/ Approx. 10 g, respectively, E3RB: Approx. 85 g/ Approx. 20 g, respectively |
E3RA: Approx. 20 g/Approx. 10 g,
E3RB: Approx. 50 g/Approx. 20 g |
|||||
Material | Case | E3RA: ABS, E3RB: Nickel-brass | |||||
Lens and Display | PMMA | ||||||
Adjuster | POM | ||||||
Nut | E3RA: POM, E3RB: Nickel-brass | ||||||
Accessories | Instruction
sheet M18 nuts (4 pcs) |
Instruction sheet
M18 nuts (2 pcs) |
* IP69K Degree of Protection Specifications
IP69K is a protection specification stipulated by DIN 40050 Part 9 of the German standards.
The test item is sprayed with 80°C water from a nozzle of a specified shape at a water pressure of 80 to 100 bar. The amount of water is 14 to 16 liters per minute.
The distance between the test item and the nozzle is 10 to 15 cm. The water is discharged at angles of 0°, 30°, 60°, and 90° from the horizontal plane for 30 seconds at each angle while the test item is rotated horizontally.
last update: January 27, 2025