General-purpose Basic Switch
last update: April 1, 2025
Item | Non-inductive load (A) | Inductive load (A) | |||||||
---|---|---|---|---|---|---|---|---|---|
Resistive load | Lamp load | Inductive load | Motor load | ||||||
Contact gap | Rated voltage | NC | NO | NC | NO | NC | NO | NC | NO |
G, H, H2, E |
125 VAC 250 VAC 500 VAC * |
15 (10) * 15 (10) * 10 |
3 2.5 2.5 |
1.5 1.25 0.75 |
15 (10) * 15 (10) * 6 |
5 3 1.5 |
2.5 1.5 0.75 |
||
G |
8 VDC 14 VDC 30 VDC 125 VDC 250 VDC |
15 15 6 0.5 0.25 |
3 3 3 0.5 0.25 |
1.5 1.5 1.5 0.5 0.25 |
15 10 5 0.05 0.03 |
5 5 5 0.05 0.03 |
2.5 2.5 2.5 0.05 0.03 |
||
H, H2 |
8 VDC 14 VDC 30 VDC 125 VDC 250 VDC |
15 15 2 0.4 0.2 |
3 3 2 0.4 0.2 |
1.5 1.5 1.4 0.4 0.2 |
15 10 1 0.03 0.02 |
5 5 1 0.03 0.02 |
2.5 2.5 1 0.03 0.02 |
||
E |
8 VDC 14 VDC 30 VDC 125 VDC 250 VDC |
15 15 15 0.75 0.3 |
3 3 3 0.75 0.3 |
1.5 1.5 1.5 0.75 0.3 |
15 15 10 0.4 0.2 |
5 5 5 0.4 0.2 |
2.5 2.5 2.5 0.4 0.2 |
||
* Figures in parentheses are for the Z-15HW78(-B) model, the AC ratings of this model are 125 and 250 V only.
Rated voltage | Non-inductive load (A) | Inductive load (A) | ||||||
---|---|---|---|---|---|---|---|---|
Resistive load | Lamp load Inductive load Motor load | Lamp load Inductive load | Motor load | |||||
NC | NO | NC | NO | NC | NO | NC | NO | |
125 VAC 250 VAC |
15 15 |
2 1 |
1 0.5 |
7 5 |
2.5 1.5 |
2 1 |
||
8 VDC 14 VDC 30 VDC 125 VDC 250 VDC |
15 15 2 0.4 0.2 |
2 2 2 0.4 0.2 |
1 1 1 0.4 0.2 |
7 7 1 0.03 0.02 |
3 3 1 0.03 0.02 |
1.5 1.5 0.5 0.03 0.02 |
||
Item | Non-inductive load (A) | Inductive load (A) | |||||||
---|---|---|---|---|---|---|---|---|---|
Resistive load | Lamp load | Inductive load | Motor load | ||||||
Contact gap |
Rated voltage |
NC | NO | NC | NO | NC | NO | NC | NO |
Series connection |
125 VAC 250 VAC |
10 10 |
4 2.5 |
2 1.5 |
6 6 |
5 3 |
2.5 1.5 |
||
30 VDC 125 VDC 250 VDC |
10 1 0.6 |
4 1 0.6 |
2 1 0.6 |
6 0.1 0.05 |
6 0.1 0.05 |
3 0.1 0.05 |
|||
Parallel connection |
125 VAC 250 VAC |
6 6 |
3 2.5 |
1.5 1.25 |
4 4 |
4 2 |
2 1 |
||
30 VDC 125 VDC 250 VDC |
6 0.6 0.3 |
4 0.6 0.3 |
2 0.6 0.3 |
4 0.1 0.05 |
6 0.1 0.05 |
3 0.1 0.05 |
|||
Rated voltage | Resistive load (A) | |
---|---|---|
NC | NO | |
125 VAC | 0.1 | |
8 VDC | 0.1 | |
14 VDC | 0.1 | |
30 VDC | 0.1 |
Z-01H | Z-15[], Z-10FY | |
---|---|---|
Minimum applicable load | 5 VDC 1 mA | 5 VDC 160 mA |
Ask your OMRON representative for information on certified models.
Rated voltage | Z-15 | Z-10F | Z-01H |
---|---|---|---|
125 VAC | 15A 1/8HP | 6A 1/10HP | 0.1A |
250 VAC | 15A 1/4HP | 6A 1/8HP | --- |
480 VAC | 15A | 6A | --- |
30 VDC | --- | --- | 0.1A |
125 VDC | 0.5A | 0.6A | --- |
250 VDC | 0.25A | 0.3A | --- |
Rated voltage | Z-15H[] | Z-15G[] | Z-01H[] |
---|---|---|---|
250 VAC | 15 A | 15 A | --- |
125 VAC | --- | --- | 0.1 A |
30 VDC | --- | --- | 0.1 A |
Rated voltage | Z-15H[] | Z-15G[] | Z-01H[] |
---|---|---|---|
250 VAC | 15 A | 15 A | --- |
125 VAC | --- | --- | 0.1 A |
30 VDC | --- | --- | 0.1 A |
Classification | Z-15 (except
micro load and flexible rod) |
Z-01H | Z-15
(flexible rod) |
Z-10F | |
---|---|---|---|---|---|
Operating speed | 0.01 mm to 1 m/s *1 | 1 mm to 1 m/s | 0.1 mm to 1 m/s *1 | ||
Operating
frequency |
Mechanical | 240 operations/min | 120 operations/min | 240 operations/min | |
Electrical | 20 operations/min | ||||
Insulation resistance | 100 MΩ min. (at 500 VDC) | ||||
Contact resistance | 15 mΩ max.
(initial value) |
50 mΩ max.
(initial value) |
15 mΩ max.
(initial value) |
25 mΩ max.
(initial value) |
|
Dielectric strength | Between contacts of
same polarity Contact gap G: 1,000 VAC, 50/60 Hz for 1 min Contact gap H: 600 VAC, 50/60 Hz for 1 min Contact gap E: 1,500 VAC, 50/60 Hz for 1 min |
Between contacts
of same polarity Contact gap G: 1,000 VAC, 50/60 Hz for 1 min Contact gap H: 600 VAC, 50/60 Hz for 1 min |
Between contacts
of same polarity Contact gap F: 1,500 VAC, 50/60 Hz for 1 min |
||
Between current-carrying metal parts and ground, and between each terminal and non-current-carrying metal parts 2,000 VAC, 50/60 Hz for 1 min | |||||
Vibration
resistance |
Malfunction | 10 to 55 Hz, 1.5-mm
double amplitude * 5 |
10 to 20 Hz, 1.5-
mm double amplitude *5 |
10 to 55 Hz, 1.5-mm double amplitude *5 | |
Shock
resistance |
Destruction | 1,000 m/s2 max. | |||
Malfunction | 300 m/s2 max. *2 *5 | 50 m/s2 max. *5 | 300 m/s2 max.
*3 *5 |
||
Durability | Mechanical | Contact gap G, H:
20,000,000 operations min. *4 Contact gap E: 300,000 operations |
1,000,000
operations min. |
500,000
operations min. *1 |
|
Electrical | Contact gap G, H:
500,000 operations min. Contact gap E: 100,000 operations min. |
100,000
operations min. |
100,000
operations min. |
||
Degree of
protection |
General-
purpose |
IP00 | |||
Drip-proof | Equivalent to IP62 (except terminals) | ||||
Degree of protection
against electric shock |
Class I | ||||
Proof tracking index
(PTI) |
175 | ||||
Ambient
operating temperature |
General-
purpose |
- 25 °C to 80 °C (with no icing) | |||
Drip-proof | - 15 °C to 80 °C (with no icing) | ||||
Ambient
operating humidity |
General-
purpose |
35% to 85%RH | |||
Drip-proof | 35% to 95%RH | ||||
Weight | Approx. 22 to 58 g | Approx. 42 to 48 g | Approx. 34 to 61 g |
Item | Classification | Z-15 | Z-01H | Z-10F |
---|---|---|---|---|
Contacts | Shape | Rivet | Single crossbar | Rivet |
Material | Silver | Gold alloy | Silver | |
Inrush current | NC | 30 A max. | 0.1 A max. | 40 A max. |
NO | 15 A max. | 0.1 A max. | 20 A max. |
last update: April 1, 2025