Model E3ZS-T81A E3FS-10B4 2M E3FS-10B4-M1-M
Sensor type Through-beam models
Safety category See Applicable standards.
Standard sensing object Opaque object: 18 mm in diameter or
greater
Opaque object: 11 mm in diameter or greater
Lens diameter Diameter 6.7 mm/diameter 9 mm
Sensing distance 0.2 to 3 m 0 to 10 m
Response time (under
stable light incident
condition)
1.0 ms (E3ZS only) 2.0 ms (E3FS only)
Startup waiting time 100 ms
Power supply voltage (Vs) 12 to 24 VDC±10% (ripple p-p 10%
max.) *1
24 VDC±10% (ripple p-p 10% max.) *1
Current consumption
(no load)
Emitter: 15 mA max.
Receiver: 20 mA max.
Emitter: 50 mA max.
Receiver: 25 mA max.
Light source (emitted
wavelength)
Red LED (660 nm) Infrared LED (870 nm)
Effective aperture angle
(EAA)
±5° (at 3 m)
Control output (OSSD) PNP transistor output, load current:
100 mA max., Residual voltage: 1 V
max., (when load current is less than
10 mA), Residual voltage: 2 V max.
(when load current is between 10 mA
and 100 mA) (except for voltage drop
due to cable extension) *1
PNP transistor output, load current: 100 mA
max.,
Residual voltage: 2 V max.
(except for voltage drop due to cable
extension) *1
Output operation mode Light-ON *2
Input voltage 22.5 to 24 VDC: Emitter OFF (source
current: 3 mA max.)
Open or 0 to 2.5 V: Emitter ON
(leakage current: 0.1 mA max.) *1
21.5 to 24 VDC: Emitter OFF (source current:
3 mA max.)
Open or 0 to 2.5 V: Emitter ON (leakage
current: 0.1 mA max.) *1
Indicators Emitter: Emitting (orange);
Receiver: Operation (orange), Stable
(green)
Emitter: Emitting (orange);
Receiver: Output OFF (red), Output ON (green)
Test functions External test (light emission stop function by test input)
Connection method Pre-wired cable (2 m) M12 connector
Protective circuits Power supply/output reverse
connection protection, load short-
circuit protection
Output reverse connection protection, load
short-circuited protection
Ambient temperature Operating: -10 to 55°C
Storage: -10 to 70°C
(with no icing or condensation)
Operating: -20 to 55°C
Storage: -30 to 70°C
(with no icing or condensation)
Ambient humidity Operating: 35% to 85%, storage: 35% to 95% (with no icing or condensation)
Ambient operating light
intensity
Incandescent lamp: 3000 lx max (light intensity on the receiver surface).
Sunlight: 10,000 lx max (light intensity on the receiver surface).
Insulation resistance 20 MΩ min. (at 500 VDC)
Dielectric strength 1000 VAC 50/60 Hz 1 min
Degree of protection IP67 (IEC standard)
Vibration
resistance
Operating limit 10 to 55 Hz, double amplitude: 0.7 mm, 50 min each in the X, Y, and Z directions
Malfunction 10 to 55 Hz, double amplitude: 1.5 mm, 2 h each in the X, Y, and Z directions
Shock
resistance
Operating limit 100 m/s2, 1000 times in the X, Y, and Z directions
Malfunction 500 m/s2, 3 times each in the X, Y, and Z directions
Material Case: Polybutylene terephthalate Case: ABS Case: Brass
Weight (packed state) Approx. 120 g (for one set including
2-m cable)
Approx. 150 g (for
one set including
2-m cable)
Approx. 125 g (for one
set including only
Sensor)
Accessories Operation manual Operation manual, nuts for mounting
Emitter/Receiver (2 each)
Applicable
standards
Sensor only IEC 60947-5-3 (PDDB)
EN ISO13849-1 (PLc/Safety Category 1)
---
Sensor
connected
to G9SP
IEC(EN)61496-1 Type2 ESPE *3
IEC (EN)61496-2 Type2 AOPD *4
EN ISO13849-1 (PLc/Safety Category 2)
Switching element category
(from IEC60947-5-3)
DC13 (control of electromagnetic load) ---

*1. Connect the Sensor to an G9SP to use it as a safety device or as part of a safety system.
*2. Depending on the wiring, this may turn ON when light is interrupted.
       For your safety, be sure to connect the pink receiver wire (mode selection input) to 24 VDC to turn ON when light is
       incident.
*3. Electro-Sensitive Protective Equipment
*4. Active Opto-electronic Protective Device