FA Communications Software
last update: August 1, 2023
Item | Requirement |
---|---|
Operating system (OS)
Japanese or English system *2 |
Microsoft Windows Server 2008 R2 (64bit*1)
Microsoft Windows Server 2012 (64bit*1) Microsoft Windows Server 2012 R2 (64bit*1) Microsoft Windows Server 2016 (64bit*1) Microsoft Windows Server 2019 (64bit*1) Microsoft Windows Server 2022 (64bit*1) Microsoft Windows 7 SP1 (32bit/64bit*1) Microsoft Windows 8.1 (32bit/64bit*1) Microsoft Windows 10 (32bit/64bit*1) Microsoft Windows 11 (64bit*1) |
Personal compute | Windows computers with Intel 32bit (x86) processor or 64bit (x64) -based processor |
Hard disk | At least 400 MB of available space |
Yes: Supported, No: Not Supported
Communications
Method |
Protocols | Specifying
memory areas |
SYSMAC Gateway SDK
(WS02-SGWC1S) |
CX-Compolet+SYSMAC Gateway
(WS02-CPLC1) |
---|---|---|---|---|
Message
Communications |
FINS | Physical address | Yes | Yes |
CIP | Physical address | Yes *1 | Yes | |
Tag names | No | Yes | ||
Tag Data Links
(EtherNet/IP) |
CIP | Physical address | Yes *2 | Yes |
Tag names | No | Yes | ||
Development languages | C, C++ | Visual Basic, C# |
*1 Please use after understanding the CIP Communications Specifications.
*2 Data is transferred through the event memory.
Yes: Supported, No: Not Supported
Personal computer | RS-232C | ||||
---|---|---|---|---|---|
PLC | SYSWAY
(Host Link C Mode) |
SYSWAY-CV
(Host Link FINS) |
CompoWay/F
(master at personal computer) |
Peripheral Bus | |
NX7/NJ1 (unit version 1.10 or later)*1
NJ5/NJ3 (unit version 1.03 or later)*2 NX5 (unit version 1.60 or later)*3 NX1 (unit version 1.30 or later)*4 NX1P (unit version 1.13 or later)*5 NY5[][]-1 (unit version 1.12 or later)*5 NX701-Z/NY5[][]-Z (unit version 1.18 or later)*6 |
No | No | No | No | |
CJ2 with EtherNet/IP functionality | Yes | Yes | No | Yes
(Peripheral Bus - CS/CJ) |
|
CJ1 | Yes | Yes | No | Yes
(Peripheral Bus - CS/CJ) |
|
CS1 | Yes | Yes | No | Yes
(Peripheral Bus - CS/CJ) |
|
CP1 | Yes *10 | Yes *10 | No | Yes *10
(Peripheral Bus - CS/CJ) |
|
C Series | C200HX/HG/HE, CQM1H | Yes | No | No | Yes
(Peripheral Bus - C) |
CPM1/CPM2 | Yes | No | No | Yes
(Peripheral Bus - C) |
|
CVM1/CV | Yes | Yes | No | Yes
(Peripheral Bus - CV) |
|
CompoWay/F Slaves, such as
Temperature Controllers |
No | No | Yes | No |
Personal computer | USB | Ethernet (LAN) | Controller Link | ||
---|---|---|---|---|---|
PLC | FINS | Ethernet (FINS) | EtherNet/IP | FINS | |
NX7/NJ1 (unit version 1.10 or later)*1
NJ5/NJ3 (unit version 1.03 or later)*2 NX5 (unit version 1.60 or later)*3 NX1 (unit version 1.30 or later)*4 NX1P (unit version 1.13 or later)*5 NY5[][]-1 (unit version 1.12 or later)*5 NX701-Z/NY5[][]-Z (unit version 1.18 or later)*6 |
No | No | Yes *7 | No | |
CJ2 with EtherNet/IP functionality | Yes | Yes | Yes
(Specification using tag names is possible.) |
Yes *8 | |
CJ1 | No | Yes *8
(Communications Units are not required for CJ1M PLCs with Ethernet functionality.) |
Yes *8,*9 | Yes *8 | |
CS1 | No | Yes *8 | Yes *8,*9 | Yes *8 | |
CP1 | Yes | Yes *11 | No | Yes *8
(CP1H only) |
|
C Series | C200HX/HG/HE, CQM1H | No | No | No | Yes *8 |
CPM1/CPM2 | No | No | No | No | |
CVM1/CV | No | Yes *8 | No | Yes *8 | |
CompoWay/F Slaves, such as
Temperature Controllers |
No | No | No | No |
Supported CX-Compolet/SYSMAC Gateway | |||
---|---|---|---|
Supported OS | Client | Windows 7 SP1 (32bit) | Ver.1.10 or higher |
Windows 7 SP1 (64bit) | Ver.1.20 or higher | ||
Windows 8.1 (32bit/64bit) | Ver.1.40 or higher | ||
Windows 10 (32bit/64bit) | Ver.1.70 or higher | ||
Windows 11 (64bit) | Ver.1.81 or higher | ||
Server | Windows Server 2008 R2 (64bit) | Ver.1.20 or higher | |
Windows Server 2012/R2 (64bit) | Ver.1.50 or higher | ||
Windows Server 2016 (64bit) | Ver.1.72 or higher | ||
Windows Server 2019 (64bit) | Ver.1.80 or higher | ||
Windows Server 2022 (64bit) | Ver.1.81 or higher | ||
Development environment | Visual Studio 2012 | Ver.1.50 or higher | |
Visual Studio 2013 | Ver.1.40 or higher | ||
Visual Studio 2015 | Ver.1.70 or higher | ||
Visual Studio 2017 | Ver.1.72 or higher | ||
Visual Studio 2019 | Ver.1.80 or higher | ||
Visual Studio 2022 | Ver.1.81 or higher |
Note1: From SYSMAC Gateway version 1.80, the unit revision has been changed to revision 4. When EtherNet/IP tag
data links are set for SYSMAC Gateway unit revision 1 to version 3, the settings need to be changed to revision
4 with Network Configurator for EtherNet/IP.
2: When EtherNet/IP tag data links are set to use SYSMAC Gateway unit revision 4 (version 1.80 or higher) as a
node, Network Configurator for EtherNet/IP version 3.72 or higher is required.
(Network Configurator for EtherNet/IP is included in
· CX-Compolet WS02-CPLC1 version 1.80 or higher
· SYSMAC Gateway WS02-SGWC1 version 1.80 or higher
3: If you need to upgrade to the latest version of CX-Compolet, consult you OMRON representative.
Ethernet | RS-232C | USB | Controller Link | ||||
---|---|---|---|---|---|---|---|
Ethernet
(FINS) |
EtherNet/IP | PCI | |||||
Supported
OS |
Client | Windows 7 SP1 (32bit) | Yes | Yes | Yes | Yes | Yes |
Windows 7 SP1 (64bit) | No | ||||||
Windows 8.1 (32bit/64bit) | Yes | Yes | Yes | Yes | No | ||
Windows 10 (32bit/64bit) | Yes | Yes | Yes | Yes | No | ||
Windows 11 (64bit) | Yes | Yes | Yes | Yes | No | ||
Server | Windows Server 2008 R2 (64bit) | Yes | Yes | Yes | Yes | No | |
Windows Server 2012/R2 (64bit) | Yes | Yes | Yes | Yes | No | ||
Windows Server 2016 (64bit) | Yes | Yes | Yes | Yes | No | ||
Windows Server 2019 (64bit) | Yes | Yes | Yes | Yes | No | ||
Windows Server 2022 (64bit) | Yes | Yes | Yes | Yes | No |
last update: August 1, 2023