Digital Panel Meter
* Information in this page is a reference that you created on the basis of information in the product catalog before the end of production, may be different from the current situation, such as goods for / supported standards options / price / features of the product. Before using, please check the compatibility and safety system.
last update: September 24, 2012
Supply voltage | 5 VDC (not internally insulated) |
---|---|
Operating voltage range | -5% to +5% of supply voltage |
Power consumption | 0.3 W (at max. DC load) |
Insulation resistance | 10 MΩ min. (at 500 VDC) between external terminal and case |
Dielectric strength | 2,000 VAC min. for 1 min between external terminal and case |
Noise immunity | ±200 V on power supply terminals in normal mode ±500 V on power supply terminals in common mode |
Vibration resistance | Malfunction: 10 to 55 Hz, 0.5-mm single amplitude for 10 min each in X, Y, and Z directions Destruction: 10 to 55 Hz, 0.75-mm single amplitude for 2 hrs each in X, Y, and Z directions |
Shock resistance | Malfunction: 98 m/s2 for 3 times each in 6 directions Destruction: 294 m/s2 for 3 times each in 6 directions |
Ambient temperature | Operating: -10° to 55°C (with no icing) Storage: -20° to 65°C (with no icing) |
Ambient humidity | Operating: 35% to 85% (with no condensation) |
Ambient operating atmosphere | No corrosive gas |
EMC | (EMI) EN61326+A1 Industry Emission Enclosure: CISPR 11 Group 1 class A: CISRP16-1/-2 Emission AC Mains: CISPR 11 Group 1 class A: CISRP16-1/-2 (EMS) EN61326+A1 Industry Immunity ESD: EN61000-4-2: 4 kV contact discharge (level 2) 8 kV air discharge (level 3) Immunity RF-interference: EN61000-4-3: 10 V/m (amplitude-modulated, 80 MHz to 1 GHz) (level 3) Immunity Fast Transient Noise: EN61000-4-4: 2 kV (power line) (level 3) Immunity Burst Noise: 1 kV line to line (I/O signal line) Immunity Surge: EN61000-4-5: 1 kV line to line 2 kV line to ground (power line) Immunity Conducted Disturbance EN61000-4-6: 3 V (0.15 to 80 MHz) (level 2) Immunity Voltage Dip/Interrupting EN61000-4-11: 0.5 cycles, 0, 180°, 100% (rated voltage) |
Input signal | DC voltage |
---|---|
A/D conversion method | Double integral method |
Sampling period | 2.5 times/s |
Display refresh period | 2.5 times/s |
Max. displayed digits | 3 1/2 digits (+1999) |
Display | 7-segment red LED |
Decimal point display position | By short-circuiting terminals |
Sign display | "-" is displayed automatically with a negative input signal. |
Overflow/underflow display | Overflow: 1[][][] Underflow: -1[][][] |
Zero suppression | Not supported. |
External control | Process value hold (terminals on rear panel short-circuited) |
Degree of protection | Front panel: IEC IP51 (see note) Case: IEC IP20 Terminals: IEC IP00 |
Input range |
Measuring range |
Max. resolution |
Input impedance |
Accuracy | Max. permissible load |
---|---|---|---|---|---|
DC voltage | ±199.9 mV | 100 μV | 100 MΩ | ±0.1%rdg ±1 digit | ±250 V |
±1.999 V | 1 mV | 100 MΩ | ±0.1%rdg ±1 digit | ±250 V | |
±19.99 V | 10 mV | 10 MΩ | ±0.1%rdg ±1 digit | ±250 V | |
±199.9 V | 100 mV | 10 MΩ | ±0.1%rdg ±1 digit | ±350 V |
Note: The above accuracy is at an ambient temperature of 23±5°C.
last update: September 24, 2012