* Information in this page is a reference that you created on the basis of information in the product catalog before the end of production, may be different from the current situation, such as goods for / supported standards options / price / features of the product. Before using, please check the compatibility and safety system.
last update: February 18, 2013
Model | E4B-TS50E4 | E4B-T1E4 | E4B-LS20E4 | E4B-LS70E4 | E4B-RS70E4 | |
---|---|---|---|---|---|---|
Sensing method | Through-beam | Convergent reflective
distance |
Convergent
reflective zone |
|||
Sensing distance | 50 cm | 1 m | 5 to 20 cm | 20 to 60 cm
(20 to 70 cm) *1 |
20 to 60 cm
(20 to 70 cm) *1 (in 10-cm divisions) |
|
Supply voltage | 12 to 24 VDC ± 10% (10.8 to 26.4 VDC) with a max. ripple ±10% (p-p) | |||||
Current
consumption |
12 VDC | Emitter: 155 mA max.
Receiver: 30 mA max. |
Emitter: 70 mA max.
Receiver: 30 mA max. |
100 mA max. | ||
24 VDC | Emitter: 80 mA max.
Receiver: 30 mA max. |
Emitter: 50 mA max.
Receiver: 30 mA max. |
50 mA max. | |||
Standard sensing
object |
10 x 10 cm flat plate | 4 x 4 cm flat plate | ||||
Differential travel | --- | 20% max. of sensing
distance |
3 cm max. | |||
Directional angle *2 | ±8° max. | |||||
Ultrasonic oscillation
frequency |
Approx. 200 kHz | |||||
Response frequency *4 | 50 Hz | 10 Hz | 50 Hz | 20 Hz | ||
Operating mode | Incident or interrupted (selectable) | |||||
Control output | NPN, 100 mA at 30 VDC (with a residual voltage of 1.5 V max.) and an output resistance of
4.7 kΩ |
|||||
Indicators | SENSING indicator (red LED) and STABILITY indicator (green LED) | |||||
Ultrasonic speed
compensation |
No | Yes | ||||
Ambient temperature | Operating: -10°C to 55°C | |||||
Ambient humidity | Operating: 35% to 95% | |||||
Temperature influence | ±10% max. of sensing distance at 20°C in the temperature range of -10°C and 55°C | |||||
Voltage influence | ±5% max. of sensing distance at a voltage between 90% and 110% of the rated power
supply voltage |
|||||
Residual voltage | 1.5 V max. under a load current of 100 mA and a cord length of 2 m | |||||
Insulation resistance | 20 MΩ min. (at 500 VDC) between current carry parts and case | |||||
Dielectric strength | 1,000 V (50/60 Hz) for 1 min between current carry parts and case | |||||
Vibration resistance | Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions | |||||
Shock resistance | Destruction: 500 m/s2 (approx. 50G) 3 times each in X, Y, and Z directions. | |||||
Degree of protection *3 | IEC IP66 (JEM IP66 water resistive) | |||||
Weight (with 2-m-long
cord and Mounting Bracket) |
Approx. 600 g (with Emitter and Receiver) | Approx. 300 g |
last update: February 18, 2013