Digital Fiber Amplifier
* Information in this page is a reference that you created on the basis of information in the product catalog before the end of production, may be different from the current situation, such as goods for / supported standards options / price / features of the product. Before using, please check the compatibility and safety system.
last update: September 24, 2012
Type |
Standard models |
Monitor- output models |
Mark-detecting models |
Infrared models |
Water- resistant models |
Twin-output models |
|||
---|---|---|---|---|---|---|---|---|---|
Output type |
NPN output |
E3X- DA11-N |
E3X- DA21-N |
E3X- DAB11-N |
E3X- DAG11-N |
E3X- DAH11-N |
E3X- DA11V |
E3X- DA11TW |
|
PNP output |
E3X- DA41-N |
E3X- DA51-N |
E3X- DAB41-N |
E3X- DAG41-N |
E3X- DAH41-N |
E3X- DA41V |
E3X- DA41TW |
||
Light source (wavelength) |
Red LED (660 nm) | Blue LED (470 nm) |
Green LED (525 nm) |
Infrared LED (870 nm) |
Red LED (660 nm) | ||||
Power supply voltage |
12 to 24 VDC±10%, ripple (p-p) 10% max. | ||||||||
Power consumption |
Normally: 960 mW max. (current consumption: 40 mA max. at power supply voltage of 24 VDC) Eco Mode: 720 mW max. (current consumption: 30 mA max. at power supply voltage of 24 VDC) Digital display not lit: 600 mW max. (current consumption: 25 mA max. at |
||||||||
Con- trol output |
ON/OFF output |
Load current: 50 mA (residual voltage (NPN/PNP): 1 V max., Open collector (NPN or PNP output, depending on the model) Light ON/Dark ON selectable |
|||||||
Monitor output |
--- | Load 1 to 5 VDC, 10 kΩ min. |
--- | ||||||
Protection circuit | Power supply reverse polarity, Output short-circuit protection, Mutual interference prevention (supported for up to 10 Units) | ||||||||
Re- sponse time |
Super- high- speed mode |
0.25 ms for operation and reset respectively | 0.5 ms for operation and reset respectively |
||||||
Standard mode |
1 ms for operation and reset respectively | 2 ms for operation and reset |
|||||||
Super- long- distance mode |
4 ms for operation and reset respectively | 7 ms for operation and reset respectively |
|||||||
Sensitivity setting | Teaching or manual method | ||||||||
Func- tions |
Timer function |
OFF-delay timer: 0 to 200 ms, 1 to 20 ms (set in 1-ms units); 20 to 200 ms (set in 5-ms units) Using Mobile Console: OFF delay, ON delay, or one shot (selectable) |
|||||||
Automatic power control (APC) |
Fiber-optic current digital control |
--- | Fiber-optic current digital control |
||||||
Zero-reset | Negative values can be displayed. | ||||||||
Initial reset |
Settings can be returned to defaults as required. | ||||||||
Monitor focus |
--- | Upper and lower limits can be set as required for every 100 digital values. |
--- | ||||||
Indicators | Operation indicator (orange), 7-segment digital incident level display (red), 7-segment digital incident level percentage display (red), threshold and excess gain 2-color double bar indicators (green and red), 7-segment digital threshold display (red) | ||||||||
Display timing | Switching between normal/peak-hold/bottom-hold possible | ||||||||
Display orientation | Switching between normal/reverse possible | ||||||||
Optical axis adjustment |
Optical axis adjustment possible (hyper-flashing function) | ||||||||
Ambient illumination (receiver side) |
Incandescent lamp: 10,000 lx max. Sunlight: 20,000 lx max. |
||||||||
Ambient temperature |
Operating: Groups of 1 to 3 Amplifiers: - 25 to 55°C Groups of 4 to 11 Amplifiers: - 25 to 50°C Groups of 12 to 16 Amplifiers: - 25 to 45°C Storage: - 30 to 70°C (with no icing or condensation) |
||||||||
Ambient humidity | Operating and storage: 35% to 85% (with no condensation) | ||||||||
Insulation resistance |
20 MΩ min. (at 500 VDC) | ||||||||
Dielectric strength | 1,000 VAC at 50/60 Hz for 1 min | ||||||||
Vibration resistance (destruction) |
10 to 55 Hz with a 1.5-mm double amplitude for 2 h each in X, Y and Z directions | ||||||||
Shock resistance (destruction) |
500m/s2, for 3 times each in X, Y and Z directions | ||||||||
Degree of protection |
IEC IP50 (with Protective Cover attached) | IEC IP66 (with Protective Cover attached) |
IEC IP50 (with Protective Cover attached) |
||||||
Connection method | Pre-wired (standard cable length: 2 m) | ||||||||
Weight (packed state) |
Approx. 100 g | Approx. 110 g | Approx. 100 g | ||||||
Materi- al |
Case | Polybutylene terephthalate (PBT) | |||||||
Cover | Polycarbonate | Polyethersul- fone |
|||||||
Accessories | Instruction sheet |
Type |
Standard models |
Monitor- output models |
Mark-detecting models |
Infrared models |
Water- resistant models * |
Twin-output models |
||
---|---|---|---|---|---|---|---|---|
Output type |
NPN output |
E3X-DA6 | E3X-DA7 | E3X-DAB6 | E3X-DAG6 | E3X-DAH6 | E3X-DA14V | E3X-DA6TW |
PNP output |
E3X-DA8 | E3X-DA9 | E3X-DAB8 | E3X-DAG8 | E3X-DAH8 | E3X-DA44V | E3X-DA8TW | |
Connection method |
Standard connector | M8 connector | Standard connector | |||||
Weight (packed state) |
Approx. 55 g | Approx. 65 g | Approx. 55 g |
* The dielectric strength for water-resistant models is 500 VAC at 50/60 Hz for 1 min.
Model | E3X-CN11/21/22 | E3X-CN12 | |
---|---|---|---|
Rated current | 2.5A | ||
Rated voltage | 50V | ||
Contact resistance | 20 mΩ max. (20 mVDC max., 100 mA max.) The figure is for connection to the Amplifier and the adjacent Connector.It does not include the conductor resistance of cable. |
||
No. of insertions (durabillty) |
50 times The figure for the number of insertions is for connection to the Amplifier and the adjacent Connector. |
||
Material | Housing | Polybutylene terephthalate(PBT) | |
Contacts | Phosphor bronze/gold-plated nickel | ||
Weight (Packed state) |
Approx. 55 g | Approx. 25 g |
Model | E3X-MC11 |
---|---|
Power supply voltage | Charged with AC adapter |
Connection method | Connected via adapter |
Weight (packed state) | Approx. 580 g (Console only: 120 g) |
Sensitivity selection | Sensing distance (mm) (The figures in parentheses apply when using the 39-F1 Lens Unit.) |
Standard object (mm) *1 (min. sensing object *2 : opaque) |
|||||
---|---|---|---|---|---|---|---|
HIGH | LOW | ||||||
11-level setting | 1 | 2 | 3 to 11 | 1 | 2 | 3 to 11 | |
Response time |
270 or 570 μ s |
0.5 or 1 ms |
1 to 200 ms or 2 to 400 ms |
270 or 570 μ s |
0.5 or 1 ms |
1 to 200 ms or 2 to 400 ms |
|
E32-T11R | 24 0 (1680) | 280 (1960) | 370 (2590) | 140 (980) | 180 (1260) | 240 (1680) | 1 dia. (0.01 dia.) |
E32-T21R | 50 | 60 | 80 | 30 | 40 | 50 | |
E32-T16WR | 580 | 690 | 910 | 350 | 450 | 580 | (0.3 dia.) *1 |
E32-T16PR | 380 | 450 | 600 | 230 | 290 | 380 | (0.2 dia.) *2 |
Sensitivity selection | Sensing distance (mm) *1 |
Standard object (mm) *2 (min. sensing object *3 : opaque) |
|||||
---|---|---|---|---|---|---|---|
HIGH | LOW | ||||||
11-level setting | 1 | 2 | 3-11 | 1 | 2 | 3-11 | |
Response time |
270 or 570 μ s |
0.5 or 1 ms |
1 to 200 ms or 2 to 400 ms |
270 or 570 μ s |
0.5 or 1 ms |
1 to 200 ms or 2 to 400 ms |
|
E32-D11R | 80 | 90 | 120 | 45 | 60 | 80 | 150 × 150 (0.01 dia.) |
E32-D21R | 13 | 15 | 20 | 7 | 10 | 13 | 25 × 25 (0.01 dia.) |
Type | Differential-output Models (Edge-detection Models) | ||
---|---|---|---|
Pre-wired | Wire-saving connector | ||
NPN output | E3X-DA11D | E3X-DA6D | |
Current consumption | 960 mW max. (current consumption: 40 mA max. at power supply voltage of 24 VDC) | ||
Control output |
ON/OFF output |
Load current: 50 mA max., (Residual voltage: 1 V max. for NPN/PNP output) Open collector Switchable between Light ON (ON at edge detection) and Dark ON (OFF at edge detection) |
|
Detection mode | Switchable between single edge and double edge detection mode | ||
Response time | Single edge: Can be set to 270 μ s, 500 μ s, 1 ms, 2 ms, 4 ms, 10 ms, 20 ms, 30 ms, 50 ms, 100 ms, or 200 ms. Double edge: Can be set to 570 μ s, 1 ms, 2 ms, 4 ms, 10 ms, 20 ms, 30 ms, 50 ms, 100 ms, 200 ms or 400 ms. |
||
Func- tions |
Timer functions |
Light ON: OFF-delay timer, Dark ON: ON-delay timer 0 to 5 s (1 to 20 ms: 1-ms units, 20 to 200 ms: 5-ms units, 200 ms to 1 s: 100 ms, 1 to 5 s: 1-s units) |
|
APC | Yes | ||
Zero-reset | Yes (Negative values can be displayed.) | ||
Initial reset | Yes (Settings can be returned to defaults.) | ||
Sensitivity selection |
Yes (HIGH/LOW) | ||
Teaching level |
One-point teaching level can be varied from 1% to 50% in increments of 1% | ||
Indicators | Operation indicator (orange), 7-segment digital incident level display (red), 7-segment digital detection level display (red) |
last update: September 24, 2012