* Information in this page is a reference that you created on the basis of information in the product catalog before the end of production, may be different from the current situation, such as goods for / supported standards options / price / features of the product. Before using, please check the compatibility and safety system.
last update: January 10, 2014
Rated time | Time range | Rated time | Time range |
---|---|---|---|
1 s | 0.1 to 1 s | 3 min | 0.3 to 3 min |
3 s | 0.3 to 3 s | 5 min | 0.5 to 5 min |
5 s | 0.5 to 5 s | 10 min | 1 to 10 min |
10 s | 1 to 10 s | 30 min | 3 to 30 min |
30 s | 3 to 30 s | 60 min | 6 to 60 min |
60 s | 6 to 60 s | 3 hrs | 0.3 to 3 hrs |
Rated supply voltage | 24, 100 to 120 or 200 to 240 VAC (50/60 Hz);
12, 24 VDC |
---|---|
Operating voltage range | 85% to 110% of rated supply voltage |
Power consumption | H3JA-8A
100 to 120 VAC: Approx. 2.6 VA (1.1 W) at 120 VAC 200 to 240 VAC: Approx. 5.0 VA (1.5 W) at 240 VAC 24 VAC: Approx. 1.0 VA (0.9 W) at 24 VAC 24 VDC: Approx. 0.8 W at 24 VDC 12 VDC: Approx. 0.5 W at 12 VDC H3JA-8C 100 to 120 VAC: Approx. 2.4 VA (0.9 W) at 120 VAC 200 to 240 VAC: Approx. 4.1 VA (1.1 W) at 240 VAC 24 VAC: Approx. 1.2 VA (1.0 W) at 24 VAC 24 VDC: Approx. 0.8 W at 24 VDC |
Control outputs | H3JA-8A: 7 A at 250 VAC, resistive load
H3JA-8C: 5 A at 250 VAC, resistive load |
Accuracy of operating
time |
±2% max. (full scale) |
---|---|
Setting error | ±7% max. (full scale) ±50 ms at 20°C |
Influence of voltage | ±2% max. (full scale) |
Influence of temperature | ±5% max. (full scale) |
Insulation resistance | 100 MΩ min. (at 500 VDC) |
Dielectric strength | 2,000 VAC, 50/60 Hz for 1 min (between current-carrying and non-current-carrying parts,
and between contact-carrying and control circuit, and between contacts of different poles) 750 VAC, 50/60 Hz for 1 min (between non-continuous contacts: H3JA-8A) 1,000 VAC, 50/60 Hz for 1 min (between non-continuous contacts: H3JA-8C) |
Impulse withstand
voltage |
3 kV (between power terminals)
4.5 kV (between current-carrying terminal and exposed non-current-carrying metal parts) |
Noise immunity | ±1.5 kV (between power terminals) and ±1.5 kV (between output terminals), square-wave
noise by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise) |
Static immunity | Destruction: 8 kV
Malfunction: 6 kV |
Vibration resistance | Destruction: 10 to 55 Hz with 0.75-mm double amplitude in 3 directions for 1 hour each.
Malfunction: 10 to 55 Hz with 0.5-mm double amplitude in 3 directions for 10 minutes each. |
Shock resistance | Destruction: 1,000 m/s2
Malfunction: 100 m/s2 |
Ambient temperature | Operating: -10°C to 55°C
Storage: -25°C to 65°C |
Ambient humidity | Operating: 35% to 85% |
Life expectancy | H3JA-8A
Mechanical: 10,000,000 operations min. Electrical: 60,000 operations min. (7 A resistive load at 250 VAC, 360 operations/h) H3JA-8C Mechanical: 10,000,000 operations min. Electrical: 100,000 operations min. (5 A resistive load at 250 VAC, 360 operations/h) |
EMC | (EMI)
Emission Enclosure: EN55011 Group 1 class B Emission AC Mains: EN55011 Group 1 class B Harmonic Current: EN61000-3-2 Voltage Fluctuation and Flickering: EN61000-3-3 (EMS) Immunity ESD: EN61000-4-2: 6 kV contact discharge (level 3), 8 kV air discharge (level 3) Immunity RF-interference from AM Radio Waves: EN61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3) Immunity Burst: EN61000-4-4: 2 kV power port and output port (level 3), 1 kV control port with capacitive clamp (level 3) Immunity Surge: EN61000-4-5: 2 kV common mode (level 3), 1 kV differential mode (level 3) |
Approved standard | UL508 *, CSA C22.2 No. 14, conforms to EN61812-1 (Pollution degree 2) |
Case color | Light gray (Munsell 5Y7/1) |
Degree of protection | IP40 (panel surface) |
Weight | H3JA-8A: Approx. 50 g
H3JA-8C: Approx. 60 g |
* The surrounding air temperature (operating) is −10 to 40°C.