| Certification body | Standards | File No. | 
|---|---|---|
| UL | UL508, CSA C22.2 No.14 | E76675 | 
| TÜV SÜD | EN60947-5-1 (certified direct opening) | Consult your OMRON representative for details. | 
| CQC(CCC) | GB/T 14048.5 | Consult your OMRON representative for details. | 
| KOSHA | KS C IEC 60947-5-1 | Consult your OMRON representative for details. | 
Note: Only models with NC contacts have a direct opening mechanism.
| Utilization category | AC-15 | DC-13 | 
|---|---|---|
| Rated operating current (Ie) | 3 A | 0.27 A | 
| Rated operating voltage (Ue) | 240 V | 250 V | 
| Type | 24 VDC | 
|---|---|
| Rated operating voltage (100% ED) | 24 VDC ±10% | 
| Current consumption | Approx. 88mA | 
| Insulation | Class A (130°C max.) | 
| Model | A22LK | |
|---|---|---|
| Allowable operating
 frequency  | 
									Mechanical | 30 operations/minute max. | 
| Electrical | 30 operations/minute max. | |
| Insulation resistance | 100 MΩ min. (at 500 VDC) | |
| Dielectric strength | Between terminals of same polarity | 2,500 VAC, 50/60Hz for 1min. | 
| Between each terminal and ground | 6,000 VAC, 50/60Hz for 1min. | |
| Vibration resistance *1 | 10 to 55 Hz, 1.5mm double amplitude (within 1 ms) | |
| Shock resistance | Destruction | 1000m/s2 | 
| Malfunction *1 | 300m/s2 | |
| Durability | Mechanical | 100,000 operations min. | 
| Electrical | 100,000 operations min. | |
| Ambient operating temperature *2 | -10 to +55°C | |
| Ambient operating humidity | 35% to 85%RH | |
| Degree of protection *3 | IP65 *3 | |
| Electric shock protection class | Class II | |
| Degree of contamination | 3 (EN60947-5-1) | |