CS-series High-speed Data Storage Unit (SPU Unit)
last update: November 11, 2019
Item | Specifications | |
---|---|---|
Unit model number | CS1W-SPU01/02-V2 | |
Applicable CPU Units | CS Series | |
Unit classification | CPU Bus Unit | |
Unit number | 0 to F | |
Mounting location | CPU Backplane or CS-series Expansion Backplane (Cannot be mounted to C200H Expansion
I/O Rack or SYSMAC BUS Remote I/O Slave Rack.) |
|
No. of Units per PLC | 16 Unit max. | |
Interfaces | PC card slot | PC card Type II, 1 slot (Conforms to PC Card Standard Release 8.0.)
Used by mounting Memory Card and HMC-AP001 Memory Card Adapter. * |
COMM port | For future expansion | |
Ethernet (LAN) ports | CS1W-SPU01-V2: One port (10/100Base-TX, RJ45 Modular Connector)
CS1W-SPU02-V2: Two ports (10/100Base-TX, RJ45 Modular Connectors) |
|
UPS power failure input | 24 VDC (+10%/-15%) input
Connect the power failure signal output line from the UPS. |
|
Settings
and operation |
Unit number switch (UNIT) | Rotary switch: Sets the unit number of the Unit as a CPU Bus Unit. |
Select switch (SELECT) | Toggle switch: Sets the number of the command to execute. | |
Enter button (ENTER) | Pushbutton switch: Confirms and starts execution of the command number set using the
select switch. |
|
DIP switch (DIPSW) | DIP switch: System settings | |
Card button | Pressed to release the Memory Card inserted in the PC card slot. The Memory Card can
then be removed. |
|
Indications | LED indicators | RUN, ERC, ERH, COMM, LAN1, LAN2, CARD, and PF-IN |
7-segment display | Displays error information and operating status of the SPU Unit.
Displays the command number set on the select switch. Displays the IP address. Display other information. |
|
Functions | Sampling
Saving files Network communications Recipe function |
|
Operating modes | Data Storage Mode and Sampling Mode (Either mode can be selected with the Change
Operating Mode command.) |
|
Current consumption | CS1W-SPU01-V2:
5 VDC, 560 mA max. (SPU Unit only) Other: Memory Card (HMC-EF[][][]): 120 mA max. (Supplied from Power Supply Unit.) |
|
CS1W-SPU02-V2:
5 VDC, 700 mA max. (SPU Unit only) Other: Memory Card (HMC-EF[][][]): 120 mA max. (Supplied from Power Supply Unit.) |
||
Dimensions | CS1W-SPU01/SPU02-V2: 35 × 130 × 101 mm (W × H × D) | |
Weight | CS1W-SPU01-V2: 280 g max. (including enclosed connector) | |
CS1W-SPU02-V2: 290 g max. (including enclosed connector) |
General Specifications: Specifications conform to the general specifications of the CS-series CPU Units.
Item | Specifications | |||
---|---|---|---|---|
Sampling | Sampling Mode | Sampling patterns | Realtime sampling: 1 pattern
Normal sampling: Up to 3 patterns |
|
Starting methods | Any one of the following methods can be used:
Start automatically when SPU Unit is started. Start with an SPU-Console operation. Start with the SPU Unit's front-panel command buttons. (Specify the command number.) Start from the CPU Unit's ladder program. |
|||
Interval | User-specified intervals: *1
Realtime sampling: 5 ms min. Normal sampling: 100 ms min. |
|||
Data Storage
Mode (Unit Ver. 1.2 or later) |
Data Collection
Patterns |
Basic Collection Pattern: 1 pattern (required)
Data Collection Patterns: Up to 64 patterns |
||
Starting methods | Basic
Collection Pattern (required) |
Any one of the following methods can be used:
Start when a specified event occurs. (Use a memory event or scheduled event. For details, see the description of Data Collection Patterns 1 to 64 below.) Start automatically when SPU Unit is started. Start with an SPU-Console operation. Start with the SPU Unit's front-panel command buttons. (Specify the command number.) Start from the CPU Unit's ladder program. |
||
Data
Collection Patterns 1 to 64 |
Either of the following methods can be used to start when an event
occurs: Memory events: Start when a CPU Unit bit or word value matches a specified condition. Up to 500 memory events can be specified. Scheduled events: Start at a specified time or time interval. Up to 16 scheduled events can be specified. |
|||
Interval | User-specified intervals: *2 *3
Basic Collection Pattern: 5 ms min. Data Collection Patterns: 100 ms min. |
|||
Data Storage
Mode (Unit Ver. 2.0 or later) |
Copy option | Basic Collection Pattern: Cannot be set.
Data Collection Patterns: Up to 10 patterns. |
||
Shared Sampling
Mode and Data Storage Mode settings |
Applicable CPU
Unit I/O memory areas |
CIO Area, WR Area, HR Area, AR Area, DM Area, and EM Area banks 0 to C | ||
Specifying I/O
memory areas |
Specify the desired CPU Unit I/O memory area (data area) with a variable.
The data type can be specified with the variable. The variables can be managed in groups. |
|||
Variable
data types |
BOOL, INT, UINT, DINT, UDINT, REAL, LREAL, STRING, CHANNEL, UINT
BCD, UDINT BCD, WORD, DWORD, CHANNEL BLOCK |
|||
Maximum number
of variables |
7,776 words total for all variables | |||
Record Condition
setting |
Set whether or not to use a record condition.
If a record condition is used, sampling data is stored within the SPU Unit only when the record condition is met. For example, sampling data can be recorded only while a specified bit is ON or a specified word contains a particular value (comparison). |
|||
Data exchange
with the CPU Unit |
CPU Bus Unit Area
CPU Unit to SPU Unit: Command execution (such as starting/stopping sampling, clearing a sampling file, or saving a sampling file). SPU Unit to CPU Unit: SPU Unit status information |
|||
Saving files | Collected data file
format |
CSV files | Indices (record number), time stamps (hh:mm:ss:ms), ns, sampling
indices (serial numbers starting at 0 when sampling is started), data for each symbol delimited with comma, records delimited with carriage returns |
|
Record
contents |
||||
Number of
sampling result records stored in one file |
Any one of the following methods can be used.
The number of records can be specified. A time period can be specified. (The number of records is calculated automatically from the time period and interval between samples.) With a version 1.2 or later SPU Unit, the number of records can be left unspecified. (In this case, data is added to the file until data collection is stopped. Records are added to one file from the start of data collection until the end.) |
|||
Scaling | Instead of directly storing the values collected from the CPU Unit's I/O memory,
the collected values can be scaled with a linear equation or upper/lower limit range before storage (unit version 1.2 or later). |
|||
File size | 2 GB per file | |||
Record size | Specified by user. | |||
Number of records | Specified by user or calculated automatically. | |||
Saving method | Data can be saved to a single file or multiple files (up to 1,200 files). | |||
Network communications | Windows network
shared folders |
Files in the Memory Card inserted in the PC card slot in the SPU Unit
can be shared with a Windows 2000/XP/Vista personal computer. |
||
FTP | FTP server/client provided. | |||
FINS
communications |
FINS server to execute FINS command
Routing to transfer FINS messages |
|||
Recipe
function |
Data Storage
Mode (Unit Ver. 2.0 or later) |
Number of fields | 10,000 | |
Recipe files | File format: CSV
The file size is restricted by the size of file that can be stored in the recipe folder. Records: Specified by the user. |
|||
Number of records | No limit, but restricted by the file size that can be stored in the recipe folder. | |||
Writing method | Conversion method: Each field is written to the specified address in the specified
data type. Continuous region method: Data written to continuos memory addresses. |
|||
Searching for
recipe keys |
Searching within files: The text string that was passed as the key is searched for
in the target search columns in the recipe files and the rows for any matches that are found are extracted as recipe data. Searching for file names: The text string that was passed as the key is searched for in the recipe file names (i.e., a search is made for key.csv), and the files with matching files names are used as recipe files just like previous versions. Key list search: A search is made for recipe keys with the method used for unit version 2.0. |
The SPU-Console is a software product used for OMRON's Storage and Processing Unit (called the SPU Unit) to set and operate the SPU Unit, monitor operating status/errors, display trend graphs, and perform other operations from a personal computer.
Item | Specifications | |
---|---|---|
Model number | WS02-SPTC1-V2 (SPU-Console Ver. 2.1) | |
System requirements | Computer hardware | Computer that meets the system requirements for Microsoft Windows XP Professional |
CD-ROM drive | Required for installation. | |
Display | Super VGA (800 × 600) or better high-resolution video adapter and monitor | |
Mouse | Must conform to the models supported by the applicable OS. | |
Network card | A separate Ethernet network card is required for computers that do not have a LAN port. | |
OS | Microsoft Windows 10 (32/64bit) *
Microsoft Windows 8.1 (32/64bit) * Microsoft Windows 8 (32/64bit) Microsoft Windows 7 (32/64bit) |
|
Application platform | Microsoft.NET Framework Version 1.1
Microsoft.NET Framework Version 2.0 |
|
Communications platform | FinsGateway Version 2003 | |
Functions | Unit information, Unit setup, variable settings, collection pattern settings, event settings,
recipe settings, trend graphs, and reports |
|
Unit information | Monitor | SPU Unit operating status and error information are displayed. |
Operation | Operations, such as starting sampling | |
Unit setup | IP network settings | |
FINS network settings | ||
Variable settings | Setting items to sample (by specifying I/O memory addresses using variables) | |
Collection pattern settings | Collection pattern settings (period, file designations for saving, etc.) | |
Recipe settings (Data Storage Mode) | Recipe settings (recipe file, write destination, key, etc.) | |
Event settings
(in Data Storage Mode) |
Memory event settings | Settings for conditions according to changes in memory (e.g., bits turning ON) |
Scheduler settings | Settings for schedules (e.g., specific times, time intervals) | |
Trend graphs | Historical trends | CSV files are read and displayed. |
Realtime trends
(Sampling Mode) |
Current sampling data is read and displayed in trend graphics in real time. |
The WS02-SPTC1-V2 contains the following software and data.
The program that performs SPU Unit settings and operations.
Microsoft .NET Framework Version 1.1 is required to run the SPU-Console. The Microsoft .NET Framework Version 1.1 Redistribution Package provided in the package can be used to install Microsoft .NET Framework in the computer.
This system data is transferred to the SPU Unit.
This communications middleware is required to run the SPU-Console.
The manual data includes the SYSMAC SPU Unit Operation Manual (Cat. No. V236), the SYSMAC SPU-Console Operation Manual (Cat. No. V230), the SYSMAC SPU-Console Version 1.3 Operation Manual (Cat. No. V231), and the SYSMAC SPU-Console Version 2.1 Operation Manual (Cat. No. V237) in PDF (portable document format).
Item | Description | ||
---|---|---|---|
Model | WS02-EDMC1-V2 | ||
System
requirements |
Processor | Intel Pentium, Celeron, or compatible processor | |
CD-ROM drive | Required for installation | ||
Display | Super VGA (800 × 600) or better high-resolution video adaptor and monitor | ||
Mouse | Mouse supported by the applicable OS. | ||
Network card | Computers without a LAN port require an Ethernet network card (sold separately). | ||
OS | Microsoft Windows 10 (32/64bit)
Microsoft Windows 8.1 (32/64bit) Microsoft Windows 8 (32/64bit) Microsoft Windows 7 (32/64bit) Microsoft Windows Server 2012 Microsoft Windows Server 2008 |
||
Application platform
(execution environment) |
Microsoft .NET Framework version 1.1
Microsoft Data Access Component 2.6 or later |
||
Communications platform | FinsGateway version 2003 | ||
Other software requirements | SPU-Console (sold separately) required to input SPU Unit settings. | ||
Registration of applicable SPU Units | SPU Units can be registered by specifying the IP address and name of the Unit
(same for the SPU-Console). |
||
Copy function | Copies files from the Memory Card in a registered SPU Unit to a specified folder on a computer hard disk. The function is enabled only when two or more is set in the Number of files Field from the SPUConsole. | ||
Settable number of copies | 256 max. | ||
Copy start conditions | Start Button or automatically on computer startup. | ||
Copy timing | Files will be saved to the computer hard disk over the network automatically when copying is enabled (data collection has stopped or files have been transferred). | ||
Storage location | Any specified folder | ||
Saved file name | File names can be created automatically using one or any combination of the following objects: Any text string, the name of the copy, the name of the source SPU Unit, the time or date (month, day, year) the file was copied, consecutive file numbers, the date or time of the start record, and the date or time of the last record. | ||
Copy monitoring cycle | Settable cycle for monitoring when copying is enabled.
Default: 10 s |
||
Status indicators | Used to check starting, started (monitoring copying), copying, stopped, and error status conditions. | ||
Log display | Press the Display of log Button to display the operating status or an error log list that shows the month/day/year, time, event ID, and description. | ||
Database storage function | Data files that are copied to a specified folder on a computer hard disk are stored in a database.
The function is enabled only when three or more is set in the Number of files Field from the SPU-Console. |
||
Settable number of data base storage
services |
65 max. | ||
Database storage start conditions | Start Button or automatically on computer startup. | ||
Storage timing | Files will be automatically stored in the database as soon as storable files are detected. | ||
Applicable databases | Microsoft Access 2000, 2002, 2003
Microsoft SQL Server 2000, 2005 Oracle Database 10g2 |
||
Copy folder monitoring cycle | Settable cycle for monitoring when there are storable files.
Default: 10 s |
||
Status indicators | Used to check whether storage is in progress (monitoring for storable files) or stopped. | ||
Log display | Press the Display of log Button to display the operating status or an error log list that shows the month/day/year, time, and description. | ||
SPU clock synchronization function | The SPU Unit (version 1.2 or later only) and CPU Unit clocks are periodically synchronized with the computer clock. |
The WS02-EDMC1-V2 software package contains the following items.
The EDMS installation program is used to install the Copy Task Service and EDMS-Console on a computer.
Microsoft .NET Framework Version 1.1 is required to run the SPU-Console. The Redistributable Package provided in the software package can be used to install .NET Framework on the computer.
The FinsGateway version 2003 communications middleware is required to run the SPU-Console.
The SPU Data Management Middleware User’s Manual (Cat. No. V232) is included in PDF format in the software package.
last update: November 11, 2019