DeviceNet Communications Unit
* Information in this page is a reference that you created on the basis of information in the product catalog before the end of production, may be different from the current situation, such as goods for / supported standards options / price / features of the product. Before using, please check the compatibility and safety system.
last update: September 24, 2012
Power supply voltage | DeviceNet | 24 VDC (for internal circuits) |
---|---|---|
External input power supply | 24 VDC (for RS-485 communications circuits and Temperature Controllers) | |
Allowable voltage range | DeviceNet | 11 to 25 VDC |
External input power supply | 20.4 to 26.4 VDC | |
Power consumption (See note 2.) |
DeviceNet | Approx. 1.1 W (for a current of 45 mA at 24 VDC) |
External input power supply | Approx. 0.5 W (for a current of 20 mA at 24 VDC) | |
Connectable Temperature Controllers | E5ZN Series | |
Maximum number of connectable Temperature Controllers | 16 | |
Ambient operating temperature | -10 to 55°C (with no icing or condensation) | |
Ambient operating humidity | 25% to 85% | |
Ambient storage temperature | -25 to 65°C (with no icing or condensation) |
Insulation resistance | 20 MΩ min. (at 100 VDC) |
---|---|
Dielectric strength | 500 VAC, 50/60 Hz for 1 min between the DIN track and all DeviceNet connector terminals and between the DIN track and all terminal socket terminals |
Vibration resistance | 10 to 55 Hz, 10 m/s2 for 2 hrs each in ±X, ±Y, and ±Z directions |
Shock resistance | 150 m/s2, 3 times each in ±X, ±Y, and ±Z directions |
Weight | 100 g max. |
Safety standards | cULus508 EMS: Electrostatic Discharge (ESD) EN61006-2, EN61000-4-2 (4 kV/contact, 8 kV/air) Radiated Electromagnetic Fields EN61006-2, EN61000-4-3 (10 V/m) Electrical Fast transients/BURST EN61006-2, EN61000-4-4 (2 kV/DC power-line, 1 kV/Signal-line) Surge Transients EN61006-2, EN61000-4-5 (line to ground : 1 kV/DC power-line) : 2 kV/Signal-line line to line : 0.5 kV/DC power-line) Conducted Disturbances EN61006-2, EN61000-4-6 (10 V) EMI: Radiated Emissions (electric field) EN50081-2 Class A |
Transmission line connection method |
RS-485 multipoint |
---|---|
Communications method | RS-485 (2-wire, half-duplex) |
Synchronization method |
Start-stop synchronization |
Baud rate | 38,400 bps |
Transmission code | ASCII |
Data bit length | 7 bits |
Stop bit length | 2 bits |
Error detection | Vertical parity (even) |
BCC (block check character) | |
Flow control | None |
Number of Units that can be connected in parallel |
16 Units max. (32 channels) |
last update: September 24, 2012