Enclosed Switch
            
        
last update: May 19, 2025
| Agency | Standard | File No. | 
|---|---|---|
| UL* | UL508 | E76675 | 
| TÜV Rheinland | EN60947-1, EN60947-5-1 | J50041904 | 
| CCC(CQC) | GB/T14048.5 | Contact your OMRON representative for details. | 
            Note: Ask your OMRON representative for information on approved models.
* UL certified for CSA C22.2 No. 14.
        
| Rated voltage | Non-inductive load (A) | Inductive load (A) | ||||||
|---|---|---|---|---|---|---|---|---|
| Resistive load | Lamp load | Inductive load | Motor load | |||||
| NC | NO | NC | NO | NC | NO | NC | NO | |
| 
                  125 VAC 250 VAC  | 
                10 10  | 
                3 2.5  | 
                1.5 1.25  | 
                10 10  | 
                5 3  | 
                2.5 1.5  | 
              ||
| 
                  8 VDC 14 VDC 30 VDC 125 VDC 250 VDC  | 
                10 10 6 0.5 0.25  | 
                3 3 3 0.4 0.2  | 
                1.5 1.5 1.5 0.4 0.2  | 
                6 6 5 0.05 0.03  | 
                5 5 5 0.05 0.03  | 
                2.5 2.5 2.5 0.05 0.03  | 
              ||
| Inrush current | NC | 30 A max. | 
|---|---|---|
| NO | 15 A max. | 
| Voltage | Carry current | Current (A) | Volt-amperes (VA) | ||
|---|---|---|---|---|---|
| Make | Break | Make | Break | ||
| 120 VAC
 240 VAC  | 
10A | 60
 30  | 
6
 3  | 
7,200 | 720 | 
| Applicable category and ratings | 
|---|
| AC-12 10 A/250 VAC | 
| Degree of protections *3 | IP67 (EN60947-5-1) | |
|---|---|---|
| Durability | Mechanical | 10,000,000 operations min. | 
| Electrical | 500,000 operations min. | |
| Operating speed | 0.05 mm/s to 0.5 m/s *1 | |
| Operating
 frequency  | 
Mechanical | 120 operations/min | 
| Electrical | 20 operations/min | |
| Insulation resistance | 100 MΩ min. (at 500 VDC) | |
| Contact resistance | 15 mΩ max. (initial value for the builtin switch when tested alone) | |
| Dielectric
 strength  | 
Between non-continuous terminals | 1,000 VAC, 50/60 Hz for 1 min | 
| Between each terminal and non-
 current-carrying metal parts  | 
2,000 VAC, 50/60 Hz for 1 min | |
| Rated insulation voltage (Ui) | 1,000 VAC | |
| Pollution degree (operating environment) | 3 (IEC947-5-1) | |
| Short-circuit protective device | 10 A-fuse type gG (IEC 60269) | |
| Protection against electric shock | Class II | |
| Proof tracking index (PTI) | 175 | |
| Rated operating current (Ie) | 10 A | |
| Rated operating voltage (Ue) | 250 VAC | |
| Vibration
 resistance  | 
Malfunction | 10 to 55 Hz, 1.5-mm double amplitude *2 | 
| Shock
 resistance  | 
Destruction | 1,000 m/s2 max. | 
| Malfunction | 300 m/s2 max. (in case of plunger model) *1 *2 | |
| Ambient operating temperature | -10°C to +80°C (with no icing) | |
| Ambient operating humidity | 35% to 95%RH | |
| Weight | Approx. 92 g (in case of ZC-Q22(21)55) | |
            *1. Only for models with plungers. (Contact your OMRON representative for information on other models.)
*2. Less than 1 ms under a free state at the operating limits.
last update: May 19, 2025