Page top

Industrial Automation

Industrial Automation

E6A2-C

Incremental 25-mm-dia. Rotary Encoder

E6A2-C

Compact Encoder with External Diameter of 25 mm

Model E6A2-CWZ3E E6A2-CWZ3C E6A2-CWZ5C
Power supply voltage 5 VDC -5% to 12 V +10%,
ripple (p-p): 5% max.
12 VDC -10% to 24 VDC +15%,
ripple (p-p): 5% max.
Current consumption *1 50 mA max. 30 mA max.
Resolution
(pulses/rotation)
100, 200, 360, 500
Output phases Phases A, B, and Z
Output configuration Voltage output NPN open-collector output
Output capacity Output resistance: 2 kΩ
Output current: 20 mA max.
Residual voltage: 0.4 V max.
(Output current: 20 mA max.)
Applied voltage: 30 VDC max.
Sink current: 30 mA max.
Residual voltage: 0.4 V max.
(at sink current of 30 mA)
Maximum response
frequency *2
30 kHz
Phase difference
between outputs
Phase difference between phases A and B: 90°±45°
Output duty factor ---
Rise and fall times of
output
1.0 μs max. (Cable length:
500 mm, Sink current: 10 mA)
1.0 μs max. (Cable length: 500 mm,
Control output voltage: 5 V, Load resistance: 1 kΩ)
Starting torque 1 mNm max.
Moment of inertia 1 × 10-7 kgm2 max.
Shaft loading Radial 10 N
Thrust 50 N
Maximum permissible
speed
5,000 r/min
Ambient temperature
range
Operating: -10 to 55°C (with no icing), Storage: -25 to 80°C (with no icing)
Ambient humidity range Operating/storage: 35% to 85% (with no condensation)
Insulation resistance 20 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength 500 VAC, 50/60 Hz for 1 min between current-carrying parts and case
Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance Destruction: 500 m/s2 3 times each in X, Y, and Z directions
Degree of protection *3 IEC 60529 IP50
Connection method Pre-wired Models (Standard cable length: 500 mm)
Material Case: Aluminum alloy, Main unit: Aluminum, Shaft: SUS420J2, Mounting Bracket: Galvanized iron
Weight (packed state) Approx. 35 g
Accessories Coupling, Servo Mounting Bracket (provided with the E6A2-CWZ[]), Hexagonal wrench, Instruction manual

Model E6A2-CW3E E6A2-CW3C E6A2-CW5C
Power supply voltage 5 VDC -5% to 12 V +10%,
ripple (p-p): 5% max.
12 VDC -10% to 24 VDC +15%,
ripple (p-p): 5% max.
Current consumption *1 30 mA max. 20 mA max.
Resolution
(pulses/rotation)
100, 200, 360, 500
Output phases Phases A and B
Output configuration Voltage output NPN open-collector output
Output capacity Output resistance: 2 kΩ
Output current: 20 mA max.
Residual voltage: 0.4 V max.
(Output current: 20 mA max.)
Applied voltage: 30 VDC max.
Sink current: 30 mA max.
Residual voltage: 0.4 V max.
(at sink current of 30 mA)
Maximum response
frequency *2
30 kHz
Phase difference
between outputs
Phase difference between phases A and B: 90°±45°
Output duty factor ---
Rise and fall times of
output
1.0 μs max. (Cable length:
500 mm, Sink current: 10 mA)
1.0 μs max. (Cable length: 500 mm,
Control output voltage: 5 V, Load resistance: 1 kΩ)
Starting torque 1 mNm max.
Moment of inertia 1 × 10-7 kgm2 max.
Shaft
loading
Radial 10 N
Thrust 50 N
Maximum permissible
speed
5,000 r/min
Ambient temperature
range
Operating: -10 to 55°C (with no icing), Storage: -25 to 80°C (with no icing)
Ambient humidity range Operating/storage: 35% to 85% (with no condensation)
Insulation resistance 20 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength 500 VAC, 50/60 Hz for 1 min between current-carrying parts and case
Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance Destruction: 500 m/s2 3 times each in X, Y, and Z directions
Degree of protection *3 IEC 60529 IP50
Connection method Pre-wired Models (Standard cable length: 500 mm)
Material Case: Aluminum alloy, Main unit: Aluminum, Shaft: SUS420J2, Mounting Bracket: Galvanized iron
Weight (packed state) Approx. 35 g
Accessories Coupling, Servo Mounting Bracket (provided with the E6A2-CWZ[]), Hexagonal wrench, Instruction manual

Model E6A2-CS3E E6A2-CS3C E6A2-CS5C
Power supply voltage 5 VDC -5% to 12 V +10%,
ripple (p-p): 5% max.
12 VDC -10% to 24 VDC +15%,
ripple (p-p): 5% max.
Current consumption *1 30 mA max. 20 mA max.
Resolution
(pulses/rotation)
10, 20, 60, 100, 200, 300, 360, 500
Output phases Phase A
Output configuration Voltage output NPN open-collector output
Output capacity Output resistance: 2 kΩ
Output current: 20 mA max.
Residual voltage: 0.4 V max.
(Output current: 20 mA max.)
Applied voltage: 30 VDC max.
Sink current: 30 mA max.
Residual voltage: 0.4 V max.
(at sink current of 30 mA)
Maximum response
frequency *2
30 kHz
Phase difference
between outputs
---
Output duty factor 50±25%
Rise and fall times of
output
1.0 μs max. (Cable length:
500 mm, Sink current: 10 mA)
1.0 μs max. (Cable length: 500 mm,
Control output voltage: 5 V, Load resistance: 1 kΩ)
Starting torque 1 mNm max.
Moment of inertia 1 × 10-7 kgm2 max.
Shaft
loading
Radial 10 N
Thrust 50 N
Maximum permissible
speed
5,000 r/min
Ambient temperature
range
Operating: -10 to 55°C (with no icing), Storage: -25 to 80°C (with no icing)
Ambient humidity range Operating/storage: 35% to 85% (with no condensation)
Insulation resistance 20 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength 500 VAC, 50/60 Hz for 1 min between current-carrying parts and case
Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance Destruction: 500 m/s2 3 times each in X, Y, and Z directions
Degree of protection *3 IEC 60529 IP50
Connection method Pre-wired Models (Standard cable length: 500 mm)
Material Case: Aluminum alloy, Main unit: Aluminum, Shaft: SUS420J2, Mounting Bracket: Galvanized iron
Weight (packed state) Approx. 35 g
Accessories Coupling, Servo Mounting Bracket (provided with the E6A2-CWZ[]), Hexagonal wrench, Instruction manual

*1. An inrush current of approximately 9 A will flow for approximately 0.3 ms when the power is turned ON.
*2. The maximum electrical response speed is determined by the resolution and maximum response frequency as
       follows:
   486_sp_1
       This means that the E6A2-C Rotary Encoder will not operate electrically if its speed exceeds the maximum electrical
       response speed.
*3. No protection is provided against water or oil.