G2RV

Slim Relay

G2RV

The World's First Industrial Slim Relay

* Information in this page is a reference that you created on the basis of information in the product catalog before the end of production, may be different from the current situation, such as goods for / supported standards options / price / features of the product. Before using, please check the compatibility and safety system.

Input Ratings

Rated
voltage
Rated current *1 Must operate
voltage
Must release
voltage
Power consumption Input voltage
AC DC % of rated voltage AC (VA)
Approx.
DC (mW)
Approx.
% of rated
voltage
50 Hz 60 Hz
12 VDC --- --- 27.2 mA 0.8 0.1 --- 300 mW ±10%
24 VDC --- --- 13.3 mA --- 300 mW
24 VAC/DC 21.1 mA 22.5 mA 13.0 mA 0.5 VA 300 mW
48 VAC/DC 8.5 mA 9.0 mA 5.2 mA 0.4 VA 250 mW
110 VAC 7.1 mA 7.5 mA --- 0.8 VA ---
230 VAC 7.3 mA 7.9 mA --- 1.7 VA ---

*1. Rated currents are measured at 23 degrees Celsius (ambient)

Contact Ratings

Item Standard type (G2RV-SL700, 500, 701, 501) Input type (G2RV-SL700-AP, 500-AP) *2
Number of poles 1 pole
Load Resistive load
(cosφ = 1)
Inductive load
(cosφ = 0.4, L/R = 7 ms)
Resistive load
(cosφ = 1)
Rated load 6 A at 250 VAC;
6 A at 30 VDC
2.5 A at 250 VAC;
2 A at 30 VDC
50 mA at 30 VAC;
50 mA at 36 VDC
Rated carry current 6 A 50 mA
Max. switching voltage 400 VAC, 125 VDC 30 VAC, 36 VDC
Max. switching current 6 A 50 mA
Max. switching power 1,500 VA
180 W
500 VA
60 W
——
Failure rate (reference
value) *1
10 mA at 5 VDC (P level) 1 mA at 100 mVDC (P level)

*1. P level: λ60 = 0.1 × 10-6/operation
*2. If a gold layer is destroyed, contact ratings of standard type are applicable.

Characteristics

Item Standard type (G2RV-SL700, 500, 701, 501) Input type (G2RV-SL700-AP, 500-AP)
Contact resistance 100 mΩ max.
Operate (set) time 20 ms max.
Release time 40 ms max.
Max. operating frequency Mechanical: 18,000 operations/hr
Electrical: 1,800 operations/hr (under rated load)
Insulation resistance 1,000 MΩ min. (at 500 VDC)
Dielectric strength 4,000 VAC, 50/60 Hz for 1 min between coil and contacts*;
1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity
Vibration resistance Destruction: 10 to 55 to 10 Hz, 0.50 mm single amplitude (1.0 mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 0.50 mm single amplitude (1.0 mm double amplitude)
Shock resistance Destruction: 1,000 m/s2
Malfunction: 200 m/s2 when energized; 100 m/s2 when not energized
Endurance Mechanical: 5,000,000 operations min.
Electrical: 100,000 Typical;
NO 70,000 operations min.;
NC 50,000 operations min.
Mechanical: 5,000,000 operations min.
Electrical: 5,000,000 operations min.
Ambient temperature Operating: -40°C to 55°C (with no icing or condensation)
Ambient humidity Operating: 5% to 85%
Weight Approx. 35 g
Overvoltage category III
Pollution degree 2
Contact material AgSnIn AgSnIn + Gold Plating
Creepage distance 7.0 mm
Clearance distance 5.5 mm

Note: Values in the above table are the initial values.

Approved Standards

UL 508 (File No. E41643)

Model Contact form Coil ratings Contact ratings Operations
G2RV-SL Series SPDT 12 to 48 VDC
24 to 230 VAC
250 VAC 6 A (Resistive Load)
30 VDC 6 A (Resistive Load)
400 VAC 2 A (Resistive Load)
6,000

IEC/VDE (EN 61810)

Contact form Coil ratings Contact ratings Operations
SPDT 12, 24 VDC
24, 48 VAC/DC
110, 230 VAC
250 VAC 6 A (Resistive Load)
30 VDC 6 A (Resistive Load)
400 VAC 2 A (Resistive Load)
50,000
50,000
6,000

Lloyd's (File No. 07/10027 (E2))

Model Contact form Coil ratings Contact ratings
G2RV-SL Series SPDT 12, 24 VDC
24, 48 VAC/DC
110, 230 VAC
250 VAC 6 A (Resistive load)
250 VAC 2.5 A (PF0.4)
30 VDC 6 A (Resistive load)
30 VDC 2 A (L/R=7ms)

Accessories

PLC Interface P2RVC-8-[]-F

P2RVC-8-O-F (for G2RV-SL700 series only)

Input Rated voltage 30 VAC/VDC max.
Current capacity 0.5 A per channel
2.0 A total current, power supply terminal
Characteristics Ambient temperature Operating: 0 to 55°C
Storage: -20 to 85°C
Overvoltage category III
Pollution degree 2

P2RVC-8-I-F (for G2RV-SL700-AP series only)

Input Rated voltage 30 VAC/VDC max.
Current capacity 0.5 A per channel
2.0 A total current, power supply terminal
Characteristics Ambient temperature Operating: 0 to 55°C
Storage: -20 to 85°C
Overvoltage category III
Pollution degree 2

Cables for PLC Interface P2RVC-8-[]-F

P2RV-4-[][][]C
P2RV-4-[][][]IMC
P2RV-4-[][][]IFC

Technical data

Control line AWG28/0.08 mm2, tin-plated copper
Diameter cable 10.7 mm (one end splits into 4 sections: A, B, C, D)
Operating voltage 60 VDC
Continuous current per signal wire 0.5 A
Max. total current, 4 bytes, each 1.0 A
Test voltage 0.5 KV, 50 Hz, 1 min
Operating temperature range -20°C to +50°C

P2RV-A[][][]C

Technical data

Control line AWG26/0.14 mm2, tin-plated copper
Diameter cable 7.6 mm
Operating voltage 60 VDC
Continuous current per signal wire 0.5 A
Max. total current 1.0 A
Test voltage 0.5 KV, 50 Hz, 1 min
Operating temperature range -20°C to +50°C

Cross bars

Max current
(EN60947-7-1 section 8.3.3/1991)
32 A
Max. Voltage 400 VAC
Max. Voltage
when cutting Cross-bar without using separation plate or end-bracket
250 VAC