* Information in this page is a reference that you created on the basis of information in the product catalog before the end of production, may be different from the current situation, such as goods for / supported standards options / price / features of the product. Before using, please check the compatibility and safety system.

Approved Standard Ratings

UL (File No. E41515), CSA (File No. LR45258)

Standard Load:
 3 A at 125 VAC
 2 A at 250 VAC
Microload:
 0.1 A at 125 VAC
 0.1 A at 30 VDC
Note: Certification has been obtained for the Switch Unit.
           For detailed information on individual products that have received certification, consult your supplier.

Ratings

For Standard Loads

Rated voltage Non-inductive load (A) Inductive load (A)
Resistive load Lamp load Inductive load Motor load
NC NO NC NO NC NO NC NO
125 VAC
250 VAC
3
2
1
0.7
0.7
0.5
2
1.5
1.5
1
1
0.7
8 VDC
14 VDC
30 VDC
125 VDC
250 VDC
3
3
2
0.4
0.2
1
1
1
0.05
0.03
2
1.5
1.5
0.4
0.2
1.5
1.5
1
0.05
0.03

Note: 1. The above values are for steady-state currents.
          2. Inductive load: Power factor = 0.4; time constant = 7 ms.
          3. The lamp load has an inrush current of 10 times the steady-state current.
          4. The motor load has an inrush current of 6 times the steady-state current.
The rated values are for testing conducted under the following conditions.
  (1) Ambient temperature: 20±2°C
  (2) Ambient humidity: 65% ±5%RH
  (3) Operating frequency: 20 times/min

For Microloads

Rating 0.1 A at 30 VDC (resistive load);
0.1 A at 125 VAC (resistive load)
Minimum applicable load 1 mA at 5 VDC

LED Lamp

Applied voltage Rated voltage Rated current
5 VDC±5% 5 VDC 8 mA
12 VAC/VDC±5% 12 VAC/VDC
24 VAC/VDC±5% 24 VAC/VDC

Characteristics

Operating
frequency
Mechanical Momentary operation models: 120 operations/min max. *1
Electrical 20 operations/min max.
Insulation resistance 100 MΩ min. (at 500 VDC)
Contact
resistance
Standard load 50 mΩ max. (initial value)
Microload 50 mΩ max. (initial value)
Dielectric
strength
Between terminals of same polarity 1,000 VAC, 50/60 Hz for 1 minute
Between terminals of different polarity 2,000 VAC, 50/60 Hz for 1 minute
Between current-carrying metal part
and ground
2,000 VAC, 50/60 Hz for 1 minute
Between each terminal and non-
current-carrying metal part
2,000 VAC, 50/60 Hz for 1 minute
Between lamp terminals 1,000 VAC, 50/60 Hz for 1 minute *2
Vibration
resistance
Malfunction 10 to 55 Hz, 1.5-mm double amplitude *3
Shock
resistance
Destruction 500 m/s2 max.
Malfunction 200 m/s2 max. *3
Life
expectancy
Mechanical Momentary operation models: 1,000,000 operations min.
Alternate operation models: 100,000 operations min.
(One operation consists of set and reset operations.)
Electrical 100,000 operations min. (rated load)
Weight Approx. 10 g
Inrush
current
NC Standard load: 10 A max.
NO Standard load: 10 A max.
Ambient operating temperature -10 to 50°C (with no icing or condensation)
Ambient operating humidity 35% to 85% RH
Ambient storage temperature -25 to 65°C (with no icing or condensation)
Degree of protection IP00
Electric shock protection class Class II
PTI (proof tracking index) 175
Pollution degree 3 (IEC 60947-5-1)

*1. With alternate operation models, 60 operations/min max. One operation cycle consists of set and reset operations.
*2. With no incandescent lamp or LED lamp mounted.
*3. Malfunction : 1 ms max.

Operating Characteristics

Operation Momentary operation models Alternate operation models
Operating characteristics
Operating force OF max. 3.92 N 4.90 N
Releasing force RF min. 0.49 N 0.294 N
Total travel TT Approx. 3 mm Approx. 3 mm
Pretravel PT max. 2.2 mm 2.2 mm
Lock travel alternate LTA min. - 0.5 mm

Contact Form

Name Contact Form
Double-throw contacts
3257_sp_6_1