D6FZ-FGS Series

Air Flow Sensor

D6FZ-FGS Series

The Best Product to Measure Compressed Air on Production Lines. Simultaneous Measurement of Leakage, Usage and Pressure.

* Information in this page is a reference that you created on the basis of information in the product catalog before the end of production, may be different from the current situation, such as goods for / supported standards options / price / features of the product. Before using, please check the compatibility and safety system.

Ratings

Air Flow Sensor

Model D6FZ-FGS1000
Applicable fluid Air or nitrogen (N2)
Working pressure 0.99MPa max.
Meas-
urement
Flow *1 Detection range 1 to 1,000L/min (std)
Resolution 0.1L/min
Accuracy ±2.0% of reading at 50 L/min (std) or more*2
±0.1%F.S. at less than 50L/min
Pressure Detection range 0 to 0.99MPa
Accuracy ±2%F.S.
Temper-
ature
Detection range -10 to 60°C
Accuracy ±1.5% (absolute temperature)
Resist-
ance to
envi-
ronment
Operating temperature -10 to 60°C (no condensation or icing)
Operating humidity 35 to 85%RH (no condensation or icing)
Vibration resistance 10 to 55Hz double amplitude: 0.7mm, Acceleration: 50m/s2 in X, Y and Z
directions (80min)
Shock resistance 150 m/s2 in 6 directions (+/-X, +/-Y, and +/-Z directions), 3 times each
Pressure loss Direct piping:10kPa max. (0.5MPa, at maximum flow)
Using coupler (TL type by NAGAHORI INDUSTRY CO., LTD.):
10kPa max. (0.5MPa, at maximum flow)
Power supply voltage 16 to 24 VDC ±10% ripple (p-p) 10% max. (Using single unit),
24 VDC ±10% ripple (p-p) 10% max. (Using multiple units) *3
Power consumption 2W max.
Measurement cycle Approx. 62.5ms
Display Display method Status display by 2-color LED (illumination/blinking)
Diplay value Presence or absence of current-carrying, flow and error alarm
Output Output
interface
Analog Current output 4 to 20mA (2 contact)*4 Max. load resistance 270Ω max.
ON/OFF Open drain output (2 outputs)*5 24 VDC 50mA max.
ON residual voltage 1.5V max., OFF leakage current 50μA max.
RS-485 2-wire half duplex communication, start-stop synch method
Baud rate: 115.2kbps (fixed), Data bit length: 8 bits (fixed), stop bit length:
1 bit (fixed), parity: even (fixed), communications protocol: compatible with
CompoWay/F
Outpus values Momentary standard flow, Integrated standard flow, pressure, temperature, unit error output
Degree of protection IP64 (except the case with the switch cover removed)
Wiring connection M12 connector (8-pin)
Connection bore diameter Rc1 (25A) bushing enables conversion to 15A and 20A
Material Cable: PVC (Polyvinyl Chloride); Main unit: Aluminum die-cast; Display: Acrylic
Dimensions 64(W) × 93(D) × 195(H) mm (excluding flange)
Weight (in package) Approx. 1.2 Kg (Approx. 1.7 Kg)
Accessories Instruction Sheet

*1. Converted value assuming the accumulated flow quantity under the conditions of 20°C at 1 atmospheric pressure
      101.3kPa.
*2. Does not include pressure and temperature accuracy. Conversion accuracy to the standard flow is ±2.5% of reading (at
      20°C, 0.5 MPa).
*3. Make sure to ground the 0V terminal, and do not ground the 24V(+) terminal. There is a risk of malfunction.
*4. Analog output comprise the momentary standard flow rate and pressure.
*5. The integrated standard flow of the pulse output can be selected from 1, 10 (factory default), 100, or 1000 L(std)/P.

Air Flow Station

Model D6FZ-FGX21
Connectable sensor D6FZ-FGT200 / D6FZ-FGT500 / D6FZ-FGS1000
Maximum number of
mounted Sensors
8 units*1
Display 7-seg. 5-digit 2-step LCD display, auxiliary information indicator displays
Recording interval 1 s, 2 s, 5 s, 10 s, 20 s, 30 s, 1 min.
Displayed data Momentary flow rate, integrated flow rate, pressure, temperature, charge/CO2
conversion value
Recorded data Momentary flow rate, integrated flow rate, volume flow rate, pressure, temperature
Operation function Conversion of integrated flow rate to charge/CO2
Recording mode Continue mode*2, Ring mode*3
External output Alarm output (Photocoupler output) *4
Communication interface Ethernet (10BASE-T, 100BASE-TX)
Internal storage device Internal memory: Approx. 4200 data items when 1 unit is connected,
approx. 650 data items when 8 units are connected
External storage device SD card (measured value saving/set value saving and reading), Recommended SD card:
HMC-SD291 (2 GB) *9 and HMC-SD491 (4 GB) (manufactured by OMRON) *5
Power supply voltage DC input: 24 VDC±10% ripple (p-p) 10% max.
Current consumption 80 mA max.
Operating temperature Without Ethernet: -10°C to 40°C (no condensation or icing),
with Ethernet: 0°C to 40°C (no condensation or icing)
Operating humidity 35 to 85%RH (no condensation or icing)
Storage humidity/
temperature
-15°C to 60°C, 20% to 85%RH (no condensation or icing)
Insulation resistance 20 MΩ (500 VDC)
Withstand voltage 1000 VAC, 50/60 Hz, 1 min.
Vibration resistance 10 to 150 Hz, 0.7 mm double amplitude,
acceleration: 50 m/s2 for each in X, Y and Z directions for 80 min
Shock resistance 150 m/s2 in 6 directions (+/-X, +/-Y, and +/-Z directions), 3 times each*6
Material ABS
Degree of protection IP30
Mounting Magnet mounting, screw mounting, hook
Dimensions 117.2(W) × 24.6(D) × 56.8(H) mm (Except protruding part)
Weight (in package) Approx. 150 g (Approx. 500 g)
Accessories Instruction Sheet, Startup Guide, T-branch connection cable*7, Alarm Output Connector*8

*1. Up to 8 units can be connected when the recording cycle is 2 seconds or longer; up to 4 units when the recording cycle is
      1 second.
*2. Automatically writes the data to the SD memory card when the internal memory reaches its capacity and continues
      recording until the SD card memory capacity reaches its limit.
      The unit stops operation if there is no SD memory card inserted when the internal memory reaches its capacity, or when
      it is write protected. (Recording can be resumed after inserting an SD memory card and outputting the data to it at a
      press of button.)
      The factory default is continue mode. Use the PC software to change the recording mode.
*3. Continues the recording of the latest measured values until the internal memory reaches its capacity. (If the internal
      memory capacity exceeds the capacity, data is overwritten from the oldest one in the memory.)
*4. Output when the range of upper/lower limit of the air flow that has been set in threshold setting mode is exceeded.
*5. When using a third party SD card, it is recommended to use a reliable and durable industrial SD card (SD standard or
      SDHC standard (not compliant with SDXC standard), Class 4 or higher, flash memory type SLC or MLC type).
      You must confirm the operation of the SD card yourself.
*6. When using a mounting magnet, be sure to install it in a location where shock is not applied.
*7. A T-branch connector to connect to D6FZ-FC02.
*8. OMRON's XW4B-02B1-H1 connector
*9. Orders for HMC-SD291 will be accepted until the end of March 2022.