Fiber Sensors
            
        
last update: October 6, 2025
| Sensing
 direction (Aperture angle)  | 
Size | Appearance
 (mm)  | 
Bending
 radius of cable  | 
Sensing distance (mm) | Optical axis
 diameter (minimum sensing object)  | 
Models | |
|---|---|---|---|---|---|---|---|
| E3X-ZV | E3NX-FA | ||||||
| Rightangle
 (Approx. 60°)  | 
M4 | 
![]()  | 
Flexible,
 R1  | 
GIGA: 2,000
 HS: 700 ST: 1,000 SHS: 280  | 
GIGA: 3,000
 HS: 1,050 ST: 1,500 SHS: 280  | 
1 dia.
 (5 μm dia./ 2 μm dia.)  | 
E32-T11N 2M | 
| Top-view
 (Approx. 60°)  | 
![]()  | 
E32-T11R 2M | |||||
| Top-view
 (Approx. 15°)  | 
![]()  | 
R25 | GIGA: 4,000 *
 HS: 2,700 ST: 4,000 * SHS: 1,080  | 
GIGA: 4,000 *
 HS: 4,000 * ST: 4,000 * SHS: 1,080  | 
2.3 dia.
 (0.1 dia./ 0.03 dia.)  | 
E32-LT11 2M | |
| Flexible,
 R1  | 
GIGA: 2,000
 HS: 2,300 ST: 3,500 SHS: 920  | 
GIGA: 4,000 *
 HS: 3,450 ST: 4,000 * SHS: 920  | 
E32-LT11R 2M | ||||
            * The optical fiber is 2m long on each side, so the sensing distance is 4,000 mm.
Note 1. The following mode names and response times apply to the modes given in the Sensing distance column.
    [E3X-ZV] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms),
         and SHS: Super-high-speed mode (50 μs)
    [E3NX-FA] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms),
          and SHS: Super-high-speed mode (30 μs)
   2. The values for the minimum sensing object are reference values that indicate values obtained in standard mode
    with the sensing distance and sensitivity set to the optimum values.
    The first value is for the E3X-ZV and the second value is for the E3NX-FA.
   3. The sensing distances for E3NX-FA are values for E3NX-FA[] models. The distances for E3NX-FAH[] infrared
    models are different.
   4. The E3X-HD Series offers the same sensing distance as the E3X-ZV.
        
| Sensing
 direction (Aperture angle)  | 
Size | Appearance
 (mm)  | 
Bending
 radius of cable  | 
Sensing distance (mm) | Optical axis
 diameter (minimum sensing object)  | 
Models | |
|---|---|---|---|---|---|---|---|
| E3X-ZV | E3NX-FA | ||||||
| Right-angle
 (Approx. 60°)  | 
M3 | Coaxial
 
IP67  | 
Flexible,
 R4  | 
GIGA: 110
 HS: 46 ST: 50 SHS: 14  | 
GIGA: 160
 HS: 69 ST: 75 SHS: 14  | 
(5 μm dia./
 2 μm dia.)  | 
E32-C31N 2M | 
| M6 | Coaxial
 
IP67  | 
GIGA: 780
 HS: 220 ST: 350 SHS: 100  | 
GIGA: 1,170
 HS: 340 ST: 520 SHS: 100  | 
E32-C91N 2M | |||
| Top-view
 (Approx. 60°)  | 
M3 |  
IP67  | 
Flexible,
 R1  | 
GIGA: 140
 HS: 40 ST: 60 SHS: 16  | 
GIGA: 210
 HS: 60 ST: 90 SHS: 16  | 
E32-D21R 2M | |
Coaxial
 
IP67  | 
R25 | GIGA: 330
 HS: 100 ST: 150 SHS: 44  | 
GIGA: 490
 HS: 150 ST: 220 SHS: 44  | 
E32-C31 2M | |||
Coaxial
 
IP67  | 
R10 | E32-C31M 1M | |||||
| M4 |  
IP67  | 
Flexible,
 R1  | 
GIGA: 140
 HS: 40 ST: 60 SHS: 16  | 
GIGA: 210
 HS: 60 ST: 90 SHS: 16  | 
E32-D211R 2M | ||
| M6 |  
IP67  | 
GIGA: 840
 HS: 240 ST: 350 SHS: 100  | 
GIGA: 1,260
 HS: 360 ST: 520 SHS: 100  | 
E32-D11R 2M | |||
Coaxial
 
IP67  | 
R25 | GIGA: 1,400
 HS: 400 ST: 600 SHS: 180  | 
GIGA: 2,100
 HS: 600 ST: 900 SHS: 180  | 
E32-CC200 2M | |||
| Top-view
 (Approx. 15°)  | 
M6 |  
IP50  | 
R25 | GIGA: 860
 HS: 250 ST: 360 SHS: 110  | 
GIGA: 1,290
 HS: 370 ST: 540 SHS: 110  | 
(1 dia./
 0.03 dia.)  | 
E32-LD11 2M | 
| Flexible,
 R1  | 
GIGA: 840
 HS: 240 ST: 350 SHS: 100  | 
GIGA: 1,260
 HS: 360 ST: 520 SHS: 100  | 
E32-LD11R 2M | ||||
            Note 1. The following mode names and response times apply to the modes given in the Sensing distance column.
    [E3X-ZV] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms),
         and SHS: Super-high-speed mode (50 μs)
    [E3NX-FA] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms),
          and SHS: Super-high-speed mode (30 μs)
   2. The values for the minimum sensing object are reference values that indicate values obtained in standard mode
    with the sensing distance and sensitivity set to the optimum values.
    The first value is for the E3X-ZV and the second value is for the E3NX-FA.
   3. The sensing distances for Reflective Fiber Units are for white paper.
    (The sensing distance for the E32-LD11 2M / E32-LD11R 2M are for glossy white paper.)
   4. The sensing distances for E3NX-FA are values for E3NX-FA[] models. The distances for E3NX-FAH[] infrared
    models are different.
   5. The E3X-HD Series offers the same sensing distance as the E3X-ZV.
        
| Aperture
 angle  | 
Size | Appearance
 (mm)  | 
Bending
 radius of cable  | 
Sensing distance (mm) | Optical axis
 diameter (minimum sensing object)  | 
Models | |
|---|---|---|---|---|---|---|---|
| E3X-ZV | E3NX-FA | ||||||
| Approx.
 15°  | 
M4 |  
IP50  | 
Flexible,
 R2  | 
GIGA: 4,000*
 HS: 2,300 ST: 3,500 SHS: 920  | 
GIGA: 4,000*
 HS: 3,450 ST: 4,000* SHS: 920  | 
2.3 dia.
 (0.1 dia./ 0.03 dia.)  | 
E32-LT11N 2M | 
| Approx.
 60°  | 
 
IP67  | 
Flexible,
 R1  | 
GIGA: 2,000
 HS: 700 ST: 1,000 SHS: 280  | 
GIGA: 3,000
 HS: 1,050 ST: 1,500 SHS: 280  | 
1 dia.
 (5 m dia./ 2 m dia.)  | 
E32-T11N 2M | |
| Aperture
 angle  | 
Size | Appearance
 (mm)  | 
Bending
 radius of cable  | 
Sensing distance (mm) | Optical axis
 diameter (minimum sensing object)  | 
Models | |
|---|---|---|---|---|---|---|---|
| E3X-ZV | E3NX-FA | ||||||
| Approx.
 15°  | 
M6 |  
IP50  | 
Flexible,
 R2  | 
GIGA: 840
 HS: 240 ST: 350 SHS: 100  | 
GIGA: 1,260
 HS: 360 ST: 520 SHS: 100  | 
(0.1 dia./
 0.03 dia.)  | 
E32-LD11N 2M | 
| Approx.
 60°  | 
M3 | Coaxial
 
IP67  | 
GIGA: 290
 HS: 90 ST: 130 SHS: 39  | 
GIGA: 440
 HS: 130 ST: 190 SHS: 39  | 
(5 m dia./
 2 m dia.)  | 
E32-C21N 2M | |
| M4 |  
IP67  | 
GIGA: 840
 HS: 240 ST: 350 SHS: 100  | 
GIGA: 1,260
 HS: 360 ST: 520 SHS: 100  | 
E32-D21N 2M | |||
| M6 | Coaxial
 
IP67  | 
Flexible,
 R4  | 
GIGA: 780
 HS: 220 ST: 350 SHS: 100  | 
GIGA: 1,170
 HS: 340 ST: 520 SHS: 100  | 
(5 m dia./
 2 m dia.)  | 
E32-C91N 2M | |
| Aperture
 angle  | 
Size | Appearance
 (mm)  | 
Bending
 radius of cable  | 
Sensing distance (mm) | Optical axis
 diameter (minimum sensing object)  | 
Models | |
|---|---|---|---|---|---|---|---|
| E3X-ZV | E3NX-FA | ||||||
| Approx.
 15°  | 
M6 |  
IP50  | 
Flexible,
 R2  | 
GIGA: 1,350
 HS: 1,000 ST: 1,200 SHS: 550  | 
GIGA: 2,020
 HS: 1,500 ST: 1,800 SHS: 550  | 
- | E32-LR11NP 2M
 + E39-RP1  | 
            * The optical fiber is 2 m long on each side, so the sensing distance is 4,000 mm.
Note 1. The following mode names and response times apply to the modes given in the Sensing distance column.
           [E3X-ZV] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms), and SHS: Super-high-speed mode (50 μs)
           [E3NX-FA] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms), and SHS: Super-high-speed mode (30 μs)
        2. The values for the minimum sensing object are reference values that indicate values obtained in standard mode with the sensing distance and sensitivity set to the optimum values.
The first value is for the E3X-ZV and the second value is for the E3NX-FA.
        3. The sensing distances for Reflective Sensors are for white paper. (The sensing distances for the E32-LD11N 2M are for glossy white paper).
        4. With Retro-reflective Models, objects with a high reflection factor may cause the Fiber Sensor to detect reflected light as incident light. Also, stable detection may not be possible for transparent objects. Check suitability beforehand.
        5. The E3X-HD Series offers the same sensing distance as the E3X-ZV.
        
| Size | Sensing
 direction  | 
Appearance
 (mm)  | 
Bending
 radius of cable  | 
Sensing distance (mm) | Optical axis
 diameter (minimum sensing object)  | 
Models | |
|---|---|---|---|---|---|---|---|
| E3X-ZV | E3NX-FA | ||||||
| 1
 dia.  | 
Top-View | 
![]()  | 
Flexible,
 R1  | 
GIGA: 450
 HS: 150 ST: 250 SHS: 60  | 
GIGA: 670
 HS: 220 ST: 370 SHS: 60  | 
0.5 dia.
 (5 μm dia./ 2 μm dia.)  | 
E32-T223R 2M | 
| 1.5
 dia.  | 
![]()  | 
Bend-
 resistant, R4  | 
GIGA: 680
 HS: 220 ST: 400 SHS: 90  | 
GIGA: 1,020
 HS: 330 ST: 600 SHS: 90  | 
E32-T22B 2M | ||
| 3
 dia.  | 
![]()  | 
Flexible,
 R1  | 
GIGA: 2,000
 HS: 700 ST: 1,000 SHS: 280  | 
GIGA: 3,000
 HS: 1,050 ST: 1,500 SHS: 280  | 
1 dia.
 (5 μm dia./ 2 μm dia.)  | 
E32-T12R 2M | |
| Side-View | 
![]()  | 
GIGA: 750
 HS: 260 ST: 450 SHS: 100  | 
GIGA: 1,120
 HS: 390 ST: 670 SHS: 100  | 
E32-T14LR 2M | |||
            Note 1. The following mode names and response times apply to the modes given in the Sensing distance column.
    [E3X-ZV] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms),
         and SHS: Super-high-speed mode (50 μs)
    [E3NX-FA] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms),
          and SHS: Super-high-speed mode (30 μs)
   2. The values for the minimum sensing object are reference values that indicate values obtained in standard mode
    with the sensing distance and sensitivity set to the optimum values.
    The first value is for the E3X-ZV and the second value is for the E3NX-FA.
   3. The sensing distances for E3NX-FA are values for E3NX-FA[] models. The distances for E3NX-FAH[] infrared
    models are different.
   4. The E3X-HD Series offers the same sensing distance as the E3X-ZV.
        
| Size | Sensing
 direction  | 
Appearance
 (mm)  | 
Bending
 radius of cable  | 
Sensing distance (mm) | Optical axis
 diameter (minimum sensing object)  | 
Models | |
|---|---|---|---|---|---|---|---|
| E3X-ZV | E3NX-FA | ||||||
| 1.5 dia. | Top-View |  
IP67  | 
Bend-
 resistant, R4  | 
GIGA: 140
 HS: 40 ST: 60 SHS: 16  | 
GIGA: 210
 HS: 60 ST: 90 SHS: 16  | 
(5 μm dia./
 2 μm dia.)  | 
E32-D22B 2M | 
| 1.5 dia.
 + 0.5 dia.  | 
The sleeve
 cannot be bent.  
IP67  | 
R4 | GIGA: 28
 HS: 8 ST: 12 SHS: 4  | 
GIGA: 42
 HS: 12 ST: 18 SHS: 4  | 
E32-D43M 1M | ||
| 3 dia. |  
IP67  | 
Flexible,
 R1  | 
GIGA: 140
 HS: 40 ST: 60 SHS: 16  | 
GIGA: 210
 HS: 60 ST: 90 SHS: 16  | 
E32-D22R 2M | ||
 
IP67  | 
Bend-
 resistant, R4  | 
GIGA: 300
 HS: 90 ST: 140 SHS: 40  | 
GIGA: 450
 HS: 130 ST: 210 SHS: 40  | 
E32-D221B 2M | |||
Coaxial
 
IP67  | 
R25 | GIGA: 700
 HS: 200 ST: 300 SHS: 90  | 
GIGA: 1,050
 HS: 300 ST: 450 SHS: 90  | 
E32-D32L 2M | |||
| 3 dia.
 + 0.8 dia.  | 
The sleeve
 cannot be bent.  
IP67  | 
GIGA: 70
 HS: 20 ST: 30 SHS: 8  | 
GIGA: 100
 HS: 30 ST: 45 SHS: 8  | 
E32-D33 2M | |||
| 6 dia. | Side-View |  
IP67  | 
Flexible,
 R1  | 
GIGA: 220
 HS: 60 ST: 100 SHS: 28  | 
GIGA: 330
 HS: 90 ST: 150 SHS: 28  | 
E32-D14LR 2M | |
            Note 1. The following mode names and response times apply to the modes given in the Sensing distance column.
    [E3X-ZV] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms),
    and SHS: Super-high-speed mode (50 μs)
    [E3NX-FA] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms),
    and SHS: Super-high-speed mode (30 μs)
   2. The values for the minimum sensing object are reference values that indicate values obtained in standard mode
    with the sensing distance and sensitivity set to the optimum values.
    The first value is for the E3X-ZV and the second value is for the E3NX-FA.
   3. The sensing distances for Reflective Fiber Units are for white paper.
   4. The sensing distances for E3NX-FA are values for E3NX-FA[] models. The distances for E3NX-FAH[] infrared
    models are different.
   5. The E3X-HD Series offers the same sensing distance as the E3X-ZV.
        
| Sensing
 direction  | 
Appearance
 (mm)  | 
Bending
 radius of cable  | 
Sensing distance (mm) | Optical axis
 diameter (minimum sensing object)  | 
Models | |
|---|---|---|---|---|---|---|
| E3X-ZV | E3NX-FA | |||||
| Top-View |  
IP67  | 
Flexible,
 R1  | 
GIGA: 2,000
 HS: 700 ST: 1,000 SHS: 280  | 
GIGA: 3,000
 HS: 1,050 ST: 1,500 SHS: 280  | 
1 dia.
 (5 μm dia./ 2 μm dia.)  | 
E32-T15XR 2M | 
 
IP67  | 
GIGA: 450
 HS: 150 ST: 250 SHS: 60  | 
GIGA: 670
 HS: 220 ST: 370 SHS: 60  | 
0.5 dia.
 (5 m dia./ 2 m dia.)  | 
E32-T25XR 2M | ||
| Side-View |  
IP67  | 
GIGA: 750
 HS: 260 ST: 450 SHS: 100  | 
GIGA: 1,120
 HS: 390 ST: 670 SHS: 100  | 
1 dia.
 (5 m dia./ 2 m dia.)  | 
E32-T15YR 2M | |
 
IP67  | 
GIGA: 170
 HS: 50 ST: 100 SHS: 20  | 
GIGA: 250
 HS: 70 ST: 150 SHS: 20  | 
0.5 dia.
 (5 m dia./ 2 m dia.)  | 
E32-T25YR 2M | ||
| Flat-View |  
IP67  | 
GIGA: 750
 HS: 260 ST: 450 SHS: 100  | 
GIGA: 1,120
 HS: 390 ST: 670 SHS: 100  | 
1 dia.
 (5 m dia./ 2 m dia.)  | 
E32-T15ZR 2M | |
 
IP67  | 
GIGA: 170
 HS: 50 ST: 100 SHS: 20  | 
GIGA: 250
 HS: 70 ST: 150 SHS: 20  | 
0.5 dia.
 (5 m dia./ 2 m dia.)  | 
E32-T25ZR 2M | ||
 
IP40  | 
GIGA: 2,400
 HS: 800 ST: 1,200 SHS: 30  | 
GIGA: 3,600
 HS: 1,200 ST: 1,800 SHS: 300  | 
3 dia.
 (0.1 dia./ 0.03 dia.)  | 
E32-LT35Z 2M | ||
            Note 1. The following mode names and response times apply to the modes given in the Sensing distance column.
    [E3X-ZV] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms),
         and SHS: Super-high-speed mode (50 μs)
    [E3NX-FA] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms),
          and SHS: Super-high-speed mode (30 μs)
   2. The values for the minimum sensing object are reference values that indicate values obtained in standard mode
    with the sensing distance and sensitivity set to the optimum values.
    The first value is for the E3X-ZV and the second value is for the E3NX-FA.
   3. The sensing distances for Reflective Fiber Units are for white paper.
   4. The sensing distances for E3NX-FA are values for E3NX-FA[] models. The distances for E3NX-FAH[] infrared
    models are different.
   5. The E3X-HD Series offers the same sensing distance as the E3X-ZV.
        
| Sensing
 direction  | 
Appearance
 (mm)  | 
Bending
 radius of cable  | 
Sensing distance (mm) | Optical axis
 diameter (minimum sensing object)  | 
Models | |
|---|---|---|---|---|---|---|
| E3X-ZV | E3NX-FA | |||||
| Top-View |  
IP67  | 
Flexible,
 R1  | 
GIGA: 840
 HS: 240 ST: 350 SHS: 100  | 
GIGA: 1,260
 HS: 360 ST: 520 SHS: 100  | 
(5 μm dia./
 2 μm dia.)  | 
E32-D15XR 2M | 
 
IP67  | 
GIGA: 140
 HS: 40 ST: 60 SHS: 16  | 
GIGA: 210
 HS: 60 ST: 90 SHS: 16  | 
E32-D25XR 2M | |||
| Side-View |  
IP67  | 
GIGA: 200
 HS: 52 ST: 100 SHS: 24  | 
GIGA: 300
 HS: 78 ST: 150 SHS: 24  | 
E32-D15YR 2M | ||
 
IP67  | 
GIGA: 40
 HS: 10 ST: 16 SHS: 4  | 
GIGA: 60
 HS: 10 ST: 20 SHS: 4  | 
E32-D25YR 2M | |||
| Flat-View |  
IP67  | 
GIGA: 200
 HS: 52 ST: 100 SHS: 24  | 
GIGA: 300
 HS: 78 ST: 150 SHS: 24  | 
E32-D15ZR 2M | ||
 
IP67  | 
GIGA: 40
 HS: 10 ST: 16 SHS: 4  | 
GIGA: 60
 HS: 10 ST: 20 SHS: 4  | 
E32-D25ZR 2M | |||
            Note 1. The following mode names and response times apply to the modes given in the Sensing distance column.
    [E3X-ZV] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms),
         and SHS: Super-high-speed mode (50 μs)
    [E3NX-FA] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms),
          and SHS: Super-high-speed mode (30 μs)
   2. The values for the minimum sensing object are reference values that indicate values obtained in standard mode
    with the sensing distance and sensitivity set to the optimum values.
    The first value is for the E3X-ZV and the second value is for the E3NX-FA.
   3. The sensing distances for Reflective Fiber Units are for white paper.
   4. The sensing distances for E3NX-FA are values for E3NX-FA[] models. The distances for E3NX-FAH[] infrared
    models are different.
   5. The E3X-HD Series offers the same sensing distance as the E3X-ZV.
        
| Sensing
 direction  | 
Appearance
 (mm)  | 
Bending
 radius of cable  | 
Sensing distance (mm) | Optical axis
 diameter (minimum sensing object)  | 
Models | |
|---|---|---|---|---|---|---|
| E3X-ZV | E3NX-FA | |||||
| Side-View | The sleeve
 cannot be bent. ![]()  | 
Flexible,
 R1  | 
GIGA: 170
 HS: 50 ST: 100 SHS: 20  | 
GIGA: 250
 HS: 75 ST: 150 SHS: 20  | 
0.5 dia.
 (5 μm dia./ 2 μm dia.)  | 
E32-T24R 2M | 
| The sleeve
 cannot be bent. ![]()  | 
R10 | GIGA: 450
 HS: 150 ST: 250 SHS: 60  | 
GIGA: 670
 HS: 220 ST: 370 SHS: 60  | 
E32-T24E 2M | ||
| Top-View | The sleeve
 cannot be bent. ![]()  | 
GIGA: 150
 HS: 50 ST: 90 SHS: 20  | 
GIGA: 220
 HS: 75 ST: 130 SHS: 20  | 
0.25 dia.
 (5 μm dia./ 2 μm dia.)  | 
E32-T33 1M | |
| The sleeve
 cannot be bent. ![]()  | 
GIGA: 510
 HS: 170 ST: 300 SHS: 68  | 
GIGA: 760
 HS: 250 ST: 450 SHS: 68  | 
0.5 dia.
 (5 μm dia./ 2 μm dia.)  | 
E32-T21-S1 2M | ||
| Sleeve bending
 radius: 5 mm ![]()  | 
Flexible,
 R1  | 
GIGA: 2,000
 HS: 700 ST: 1,000 SHS: 280  | 
GIGA: 3,000
 HS: 1,050 ST: 1,500 SHS: 280  | 
1 dia.
 (5 μm dia./ 2 μm dia.)  | 
E32-TC200BR 2M | |
            Note 1. The following mode names and response times apply to the modes given in the Sensing distance column.
    [E3X-ZV] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms),
         and SHS: Super-high-speed mode (50 μs)
    [E3NX-FA] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms),
          and SHS: Super-high-speed mode (30 μs)
   2. The values for the minimum sensing object are reference values that indicate values obtained in standard mode
    with the sensing distance and sensitivity set to the optimum values.
    The first value is for the E3X-ZV and the second value is for the E3NX-FA.
   3. The sensing distances for E3NX-FA are values for E3NX-FA[] models. The distances for E3NX-FAH[] infrared
    models are different.
   4. The E3X-HD Series offers the same sensing distance as the E3X-ZV.
        
| Sensing
 direction  | 
Appearance
 (mm)  | 
Bending
 radius of cable  | 
Sensing distance (mm) | Optical axis
 diameter (minimum sensing object)  | 
Models | |
|---|---|---|---|---|---|---|
| E3X-ZV | E3NX-FA | |||||
| Side-View | The sleeve
 cannot be bent ![]()  | 
Flexible,
 R1  | 
GIGA: 70
 HS: 20 ST: 30 SHS: 8  | 
GIGA: 100
 HS: 30 ST: 45 SHS: 8  | 
(5 μm dia./
 2 μm dia.)  | 
E32-D24R 2M | 
| Sleeve bending
 radius: 25 mm ![]()  | 
R25 | GIGA: 120
 HS: 45 ST: 53 SHS: 14  | 
GIGA: 180
 HS: 67 ST: 79 SHS: 14  | 
E32-D24-S2 2M | ||
| Top-View | The sleeve
 cannot be bent. ![]()  | 
R4 | GIGA: 28
 HS: 8 ST: 12 SHS: 4  | 
GIGA: 42
 HS: 12 ST: 18 SHS: 4  | 
E32-D43M 1M | |
| The sleeve
 cannot be bent. ![]()  | 
GIGA: 14
 HS: 4 ST: 6 SHS: 2  | 
GIGA: 21
 HS: 6 ST: 9 SHS: 2  | 
E32-D331 2M | |||
| The sleeve
 cannot be bent. ![]()  | 
R25 | GIGA: 70
 HS: 20 ST: 30 SHS: 8  | 
GIGA: 100
 HS: 30 ST: 45 SHS: 8  | 
E32-D33 2M | ||
| The sleeve
 cannot be bent. ![]()  | 
R4 | GIGA: 63
 HS: 18 ST: 27 SHS: 7  | 
GIGA: 94
 HS: 27 ST: 40 SHS: 7  | 
E32-D32-S1 0.5M | ||
| The sleeve
 cannot be bent. ![]()  | 
E32-D31-S1 0.5M | |||||
| Sleeve bending
 radius: 5 mm ![]()  | 
Flexible,
 R1  | 
GIGA: 140
 HS: 40 ST: 60 SHS: 16  | 
GIGA: 210
 HS: 60 ST: 90 SHS: 16  | 
E32-DC200F4R 2M | ||
| The sleeve
 cannot be bent. ![]()  | 
R10 | GIGA: 250
 HS: 72 ST: 110 SHS: 30  | 
GIGA: 370
 HS: 100 ST: 160 SHS: 30  | 
E32-D22-S1 2M | ||
| Sleeve bending
 radius: 10 mm ![]()  | 
E32-D21-S3 2M | |||||
| The sleeve
 cannot be bent. ![]()  | 
Flexible,
 R1  | 
GIGA: 840
 HS: 240 ST: 350 SHS: 100  | 
GIGA: 1,260
 HS: 360 ST: 520 SHS: 100  | 
E32-DC200BR 2M | ||
| Sleeve bending
 radius: 10 mm ![]()  | 
R10 | GIGA: 250
 HS: 72 ST: 110 SHS: 30  | 
GIGA: 370
 HS: 100 ST: 160 SHS: 30  | 
E32-D25-S3 2M | ||
            Note 1. The following mode names and response times apply to the modes given in the Sensing distance column.
    [E3X-ZV] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms),
         and SHS: Super-high-speed mode (50 μs)
    [E3NX-FA] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms),
          and SHS: Super-high-speed mode (30 μs)
   2. The values for the minimum sensing object are reference values that indicate values obtained in standard mode
    with the sensing distance and sensitivity set to the optimum values.
    The first value is for the E3X-ZV and the second value is for the E3NX-FA.
   3. The sensing distances for Reflective Fiber Units are for white paper.
   4. The sensing distances for E3NX-FA are values for E3NX-FA[] models. The distances for E3NX-FAH[] infrared
    models are different.
   5. The E3X-HD Series offers the same sensing distance as the E3X-ZV.
        
| Type | Spot
 diameter  | 
										Center
 distance (mm)  | 
										Lens Units | Lens Units + Fiber Units | Fiber Unit | |
|---|---|---|---|---|---|---|
| Models | Appearance (mm) | Bending
 radius of cable  | 
										Model | |||
| Variable
 spot  | 
										0.1 to 0.6 dia. | 6 to 15 | E39-F3A | 
											![]()  | 
										R25 | E32-C42 1M | 
| 0.3 to 1.6 dia. | 10 to 30 | E39-F17 | 
											![]()  | 
									|||
| Type | Spot
 diameter  | 
										Center
 distance (mm)  | 
										Lens Units | Lens Units + Fiber Units | Fiber Unit | |
|---|---|---|---|---|---|---|
| Models | Appearance (mm) | Bending
 radius of cable  | 
										Model | |||
| Parallel
 light  | 
										4 dia. | 0 to 20 | E39-F3C | 
											![]()  | 
										R25 | E32-C31 2M | 
											![]()  | 
										Flexible, R2 | E32-C21N 2M | ||||
| Type | Spot
 diameter  | 
										Center distance
 (mm)  | 
										Appearance (mm) | Bending
 radius of cable  | 
										Models | 
|---|---|---|---|---|---|
| Short-distance,
 Small-spot  | 
										0.1 dia. | 5 | 
											![]() IP50  | 
										R25 | E32-C42S 1M | 
| Long-distance,
 Small-spot  | 
										6 dia. | 50 | 
											![]() IP50  | 
										E32-L15 2M | 
* The spot diameter and the center distance are the same when using with E3X-ZV series or E3NX-FA[] series. The distance for E3NX-FAH[] infrared models varies.
| Type | Spot
 diameter  | 
										Center
 distance (mm)  | 
										Lens Units | Lens Units + Fiber Units | Fiber Unit | |
|---|---|---|---|---|---|---|
| Models | Appearance (mm) | Bending
 radius of cable  | 
										Models | |||
| Short-
 distance, small-spot  | 
										0.1 dia. | 7 | E39-F3A-5 | ![]()  | 
										R25 | E32-C41 1M | 
| 0.5 dia. | ![]()  | 
										E32-C31 2M | ||||
![]()  | 
										Flexible, R2 | E32-C21N 2M | ||||
| Medium-
 distance, small-spot  | 
										0.2 dia. | 17 | E39-F3B | ![]()  | 
										R25 | E32-C41 1M | 
| 0.5 dia. | ![]()  | 
										E32-C31 2M | ||||
![]()  | 
										Flexible, R2 | E32-C21N 2M | ||||
| Long-
 distance, small-spot  | 
										3 dia. | 50 | E39-F18 | ![]()  | 
										R25 | E32-CC200 2M | 
![]()  | 
										Flexible, R4 | E32-C91N 2M | ||||
* The spot diameter and the center distance are the same when using with E3X-ZV series or E3NX-FA[] series. The distance for E3NX-FAH[] infrared models varies.
| Sensing
 direction  | 
Aperture
 angle  | 
Appearance
 (mm)  | 
Bending
 radius of cable  | 
Sensing distance (mm) | Optical axis
 diameter (minimum sensing object)  | 
Models | |
|---|---|---|---|---|---|---|---|
| E3X-ZV | E3NX-FA | ||||||
| Right-
 angle  | 
15° |  
IP50  | 
Flexible,
 R2  | 
GIGA: 4,000 *1
 HS: 2,300 ST: 3,500 SHS: 920  | 
GIGA: 4,000 *1
 HS: 3,450 ST: 4,000 *1 SHS: 920  | 
2.3 dia.
 (0.1 dia./ 0.03 dia.)  | 
E32-LT11N 2M | 
| Top-
 View  | 
10° |  
IP67  | 
R25 | GIGA: 20,000 *2
 HS: 20,000 *2 ST: 20,000 *2 SHS: 8,000  | 
GIGA: 20,000 *2
 HS: 20,000 *2 ST: 20,000 *2 SHS: 8,000  | 
10 dia. | E32-T17L 10M | 
| 15° |  
IP50  | 
GIGA: 4,000 *1
 HS: 2,700 ST: 4,000 *1 SHS: 1,080  | 
GIGA: 4,000 *1
 HS: 4,000 *1 ST: 4,000 *1 SHS: 1,080  | 
2.3 dia.
 (0.1 dia./ 0.03 dia.)  | 
E32-LT11 2M | ||
| Flexible,
 R1  | 
GIGA: 4,000 *1
 HS: 2,300 ST: 3,500 SHS: 920  | 
GIGA: 4,000 *1
 HS: 3,450 ST: 4,000 *1 SHS: 920  | 
E32-LT11R 2M | ||||
| Side-
 View  | 
30° |  
IP67  | 
R25 | GIGA: 4,000 *1
 HS: 4,000 *1 ST: 4,000 *1 SHS: 1,800  | 
GIGA: 4,000 *1
 HS: 4,000 *1 ST: 4,000 *1 SHS: 1,800  | 
4 dia.
 (0.1 dia./ 0.03 dia.)  | 
E32-T14 2M | 
            *1. The optical fiber is 2 m long on each side, so the sensing distance is 4,000 mm.
*2. The optical fiber is 10 m long on each side, so the sensing distance is 20,000 mm.
Note1. The sensing distances for the E3NX-FA are values for E3NX-FA[] devices.
    The distance for E3NX-FAH[] infrared models varies.
  2. The E3X-HD Series offers the same sensing distance as the E3X-ZV.
        
| Sensing
 direction  | 
Aperture
 angle  | 
Appearance
 (mm)  | 
Bending
 radius of cable  | 
Sensing distance (mm) | Optical
 axis diameter (minimum sensing object)  | 
Models | |
|---|---|---|---|---|---|---|---|
| E3X-ZV | E3NX-FA | ||||||
| Top-View | 4° |   IP40 | 
Bend-
 resistant, R4  | 
GIGA: 40 to 2,800
 HS: 40 to 900 ST: 40 to 1,400 SHS: 40 to 480  | 
GIGA: 40 to 4,200
 HS: 40 to 1,350 ST: 40 to 2,100 SHS: 40 to 720  | 
- | E32-D16 2M | 
            Note 1. The following mode names and response times apply to the modes given in the Sensing distance column.
    [E3X-ZV] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms),
         and SHS: Super-high-speed mode (50 μs)
    [E3NX-FA] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms),
          and SHS: Super-high-speed mode (30 μs)
   2. The values for the minimum sensing object are reference values that indicate values obtained in standard mode
    with the sensing distance and sensitivity set to the optimum values.
    The first value is for the E3X-ZV and the second value is for the E3NX-FA.
   3. The sensing distances for Reflective Fiber Units are for white paper.
   4. The sensing distances for the E3NX-FA are values for E3NX-FA[] devices. The distance for E3NX-FAH[] infrared
    models varies.
   5. The E3X-HD Series offers the same sensing distance as the E3X-ZV.
        
| Lens Units | Type | High-power
 (incident level: 50 times)  | 
Ultra-high-power
 (incident level: 160 times)  | 
Side-View
 (incident level: 0.8 times)  | 
|||
|---|---|---|---|---|---|---|---|
| Models | E39-F1 | E39-F16 | E39-F2 | ||||
| Appearance | 
![]()  | 
![]()  | 
![]()  | 
||||
| Aperture angle | Approx. 12° | Approx. 6° | Approx. 60° | ||||
| Fiber Units | Optical axis
 diameter (minimum sensing object)  | 
4 dia. (0.1 dia.) | 7.2 dia. | 3 dia. (0.1 dia.) | |||
| Models | Appearance
 (mm)  | 
Sensing distance (mm) | |||||
| E3X-ZV | E3NX-FA | E3X-ZV | E3NX-FA | E3X-ZV | E3NX-FA | ||
| E32-T11N 2M | 
![]()  | 
GIGA: 4,000 *
 HS: 4,000 * ST: 4,000 * SHS: 2,000  | 
GIGA: 4,000 *
 HS: 4,000 * ST: 4,000 * SHS: 2,000  | 
GIGA: 4,000 *
 HS: 4,000 * ST: 4,000 * SHS: 3,600  | 
GIGA: 4,000 *
 HS: 4,000 * ST: 4,000 * SHS: 3,600  | 
- | - | 
| E32-T11R 2M | 
![]()  | 
GIGA: 4,000 *
 HS: 4,000 * ST: 4,000 * SHS: 2,000  | 
GIGA: 4,000 *
 HS: 4,000 * ST: 4,000 * SHS: 2,000  | 
GIGA: 4,000 *
 HS: 4,000 * ST: 4,000 * SHS: 3,600  | 
GIGA: 4,000 *
 HS: 4,000 * ST: 4,000 * SHS: 3,600  | 
GIGA: 1,450
 HS: 500 ST: 800 SHS: 200  | 
GIGA: 2,170
 HS: 750 ST: 1,200 SHS: 200  | 
| E32-T11 2M | 
![]()  | 
GIGA: 4,000 *
 HS: 4,000 * ST: 4,000 * SHS: 1,860  | 
GIGA: 4,000 *
 HS: 4,000 * ST: 4,000 * SHS: 1,860  | 
GIGA: 4,000 *
 HS: 4,000 * ST: 4,000 * SHS: 4,000 *  | 
GIGA: 4,000 *
 HS: 4,000 * ST: 4,000 * SHS: 4,000 *  | 
GIGA: 2,300
 HS: 860 ST: 1,320 SHS: 320  | 
GIGA: 3,450
 HS: 1,290 ST: 1,980 SHS: 320  | 
            * The optical fiber is 2 m long on each side, so the sensing distance is 4,000 mm.
Note 1. The following mode names and response times apply to the modes given in the Sensing distance column.
    [E3X-ZV] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms),
         and SHS: Super-high-speed mode (50 μs)
    [E3NX-FA] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms),
          and SHS: Super-high-speed mode (30 μs)
   2. The values for the minimum sensing object are reference values that indicate values obtained in standard mode
    with the sensing distance and sensitivity set to the optimum values.
    The first value is for the E3X-ZV and the second value is for the E3NX-FA.
   3. The sensing distances for the E3NX-FA are values for E3NX-FA[] devices.
    The distance for E3NX-FAH[] infrared models varies.
   4. The E3X-HD Series offers the same sensing distance as the E3X-ZV.
        
| Lens Units | Type | High-power
 (incident level: 50 times)  | 
Ultra-high-power
 (incident level: 160 times)  | 
Side-View
 (incident level: 0.8 times)  | 
|||
|---|---|---|---|---|---|---|---|
| Models | E39-F1 | E39-F16 | E39-F2 | ||||
| Appearance | 
![]()  | 
![]()  | 
![]()  | 
||||
| Aperture angle | Approx. 12° | Approx. 6° | Approx. 60° | ||||
| Fiber Units | Optical axis
 diameter (minimum sensing object)  | 
4 dia. (0.1 dia.) | 7.2 dia. | 3 dia. (0.1 dia.) | |||
| Models | Appearance (mm) | Sensing distance (mm) | |||||
| E3X-ZV | E3NX-FA | E3X-ZV | E3NX-FA | E3X-ZV | E3NX-FA | ||
| E32-T51R 2M | Heat-resistant up
 to 100°C ![]()  | 
GIGA: 4,000 *
 HS: 3,900 ST: 4,000 * SHS: 1,500  | 
GIGA: 4,000 *
 HS: 4,000 * ST: 4,000 * SHS: 1,500  | 
GIGA: 4,000 *
 HS: 4,000 * ST: 4,000 * SHS: 4,000 *  | 
GIGA: 4,000 *
 HS: 4,000 * ST: 4,000 * SHS: 4,000 *  | 
GIGA: 1,400
 HS: 500 ST: 720 SHS: 200  | 
GIGA: 2,100
 HS: 750 ST: 1,080 SHS: 200  | 
| E32-T81R-S 2M | Heat-resistant up
 to 200°C ![]()  | 
GIGA: 4,000 *
 HS: 2,700 ST: 4,000 * SHS: 1,000  | 
GIGA: 4,000 *
 HS: 4,000 * ST: 4,000 * SHS: 1,000  | 
GIGA: 4,000 *
 HS: 4,000 * ST: 4,000 * SHS: 1,800  | 
GIGA: 4,000 *
 HS: 4,000 * ST: 4,000 * SHS: 1,800  | 
GIGA: 1,000
 HS: 360 ST: 550 SHS: 140  | 
GIGA: 1,500
 HS: 540 ST: 820 SHS: 140  | 
| E32-T61-S 2M | Heat-resistant up
 to 350°C (200°C) (See Note 3) ![]()  | 
GIGA: 4,000 *
 HS: 4,000 * ST: 4,000 * SHS: 1,800  | 
GIGA: 4,000 *
 HS: 4,000 * ST: 4,000 * SHS: 1,800  | 
GIGA: 4,000 *
 HS: 4,000 * ST: 4,000 * SHS: 3,100  | 
GIGA: 4,000 *
 HS: 4,000 * ST: 4,000 * SHS: 3,100  | 
GIGA: 1,680
 HS: 600 ST: 900 SHS: 240  | 
GIGA: 2,520
 HS: 900 ST: 1,350 SHS: 240  | 
            * The optical fiber is 2 m long on each side, so the sensing distance is 4,000 mm.
Note 1. The following mode names and response times apply to the modes given in the Sensing distance column.
    [E3X-ZV] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms),
         and SHS: Super-high-speed mode (50 μs)
    [E3NX-FA] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms),
          and SHS: Super-high-speed mode (30 μs)
   2. The values for the minimum sensing object are reference values that indicate values obtained in standard mode
    with the sensing distance and sensitivity set to the optimum values.
    The first value is for the E3X-ZV and the second value is for the E3NX-FA.
   3. The ambient temperature of E32-T61-S must be between −40 to 200°C when using it with E39-F1 or E39-F2 Lens
    Unit.
    The ambient temperature of E32-T61-S must be between −40 to 350°C when using it with E39-F16 Lens Unit.
   4. The sensing distances for the E3NX-FA are values for E3NX-FA[] devices. The distance for E3NX-FAH[] infrared
    models varies.
   5. The E3X-HD Series offers the same sensing distance as the E3X-ZV.
        
| Lens Units | Type | High-power
 (incident level: 50 times)  | 
Ultra-high-power
 (incident level: 160 times)  | 
||
|---|---|---|---|---|---|
| Models | E39-F1-33 | E39-F16 | |||
| Appearance | 
![]()  | 
![]()  | 
|||
| Aperture angle | Approx. 12° | Approx. 6° | |||
| Fiber Units | Optical axis diameter
 (minimum sensing object)  | 
4 dia. (0.1 dia.) | 7.2 dia. | ||
| Models | Appearance (mm) | Sensing distance (mm) | |||
| E3X-ZV | E3NX-FA | E3X-ZV | E3NX-FA | ||
| E32-T51 2M | Heat-resistant up to 150°C
![]()  | 
GIGA: 4,000 *
 HS: 2,300 ST: 4,000 * SHS: 1,400  | 
GIGA: 4,000 *
 HS: 3,450 ST: 4,000 * SHS: 1,400  | 
GIGA: 4,000 *
 HS: 4,000 * ST: 4,000 * SHS: 4,000 *  | 
GIGA: 4,000 *
 HS: 4,000 * ST: 4,000 * SHS: 4,000 *  | 
            * The optical fiber is 2 m long on each side, so the sensing distance is 4,000 mm.
Note 1. The following mode names and response times apply to the modes given in the Sensing distance column.
    [E3X-ZV] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms),
         and SHS: Super-high-speed mode (50 μs)
    [E3NX-FA] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms),
          and SHS: Super-high-speed mode (30 μs)
   2. The values for the minimum sensing object are reference values that indicate values obtained in standard mode
    with the sensing distance and sensitivity set to the optimum values.
    The first value is for the E3X-ZV and the second value is for the E3NX-FA.
   3. The sensing distances for the E3NX-FA are values for E3NX-FA[] devices. The distance for E3NX-FAH[] infrared
    models varies.
   4. The E3X-HD Series offers the same sensing distance as the E3X-ZV.
        
| Sensing
 direction  | 
Aperture
 angle  | 
Appearance
 (mm)  | 
Bending
 radius of cable  | 
Sensing distance (mm) | Optical axis
 diameter (minimum sensing object)  | 
Models | |
|---|---|---|---|---|---|---|---|
| E3X-ZV | E3NX-FA | ||||||
| Side-View | 1.5° | 
![]() IP50  | 
Flexible,
 R1  | 
GIGA: 3,220
 HS: 1,200 ST: 1,780 SHS: 500  | 
GIGA: 4,000 *
 HS: 1,800 ST: 2,670 SHS: 500  | 
2 dia.
 (0.1 dia./ 0.03 dia.)  | 
E32-A03 2M | 
![]()  | 
R10 | E32-A03-1 2M | |||||
| 3.4° | 
![]() IP50  | 
GIGA: 1,280
 HS: 450 ST: 680 SHS: 200  | 
GIGA: 1,920
 HS: 670 ST: 1,020 SHS: 200  | 
1.2 dia.
 (0.1 dia./ 0.03 dia.)  | 
E32-A04 2M | ||
| 4° | 
![]()  | 
Flexible,
 R1  | 
GIGA: 4,000 *
 HS: 1,460 ST: 2,200 SHS: 580  | 
GIGA: 4,000 *
 HS: 2,190 ST: 3,300 SHS: 580  | 
2 dia.
 (0.1 dia./ 0.03 dia.)  | 
E32-T24SR 2M | |
| R10 | GIGA: 4,000 *
 HS: 1,740 ST: 2,600 SHS: 700  | 
GIGA: 4,000 *
 HS: 2,610 ST: 3,900 SHS: 700  | 
E32-T24S 2M | ||||
| Top-View | 
![]()  | 
GIGA: 4,000 *
 HS: 2,500 ST: 3,800 SHS: 1,000  | 
GIGA: 4,000 *
 HS: 3,750 ST: 4,000 * SHS: 1,000  | 
1.7 dia.
 (0.1 dia./ 0.03 dia.)  | 
E32-T22S 2M | ||
            * The optical fiber is 2 m long on each side, so the sensing distance is 4,000 mm.
Note 1. The following mode names and response times apply to the modes given in the Sensing distance column.
    [E3X-ZV] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms),
         and SHS: Super-high-speed mode (50 μs)
    [E3NX-FA] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms),
          and SHS: Super-high-speed mode (30 μs)
   2. The values for the minimum sensing object are reference values that indicate values obtained in standard mode
    with the sensing distance and sensitivity set to the optimum values.
    The first value is for the E3X-ZV and the second value is for the E3NX-FA.
   3. The sensing distances for the E3NX-FA are values for E3NX-FA[] devices. The distance for E3NX-FAH[] infrared
    models varies.
   4. The E3X-HD Series offers the same sensing distance as the E3X-ZV.
        
| Sensing
 direction  | 
Appearance
 (mm)  | 
Bending
 radius of cable  | 
Sensing distance (mm) | Standard
 sensing object (minimum sensing object)  | 
Models | |
|---|---|---|---|---|---|---|
| E3X-ZV | E3NX-FA | |||||
| Flat-View | 
![]()  | 
R25 | GIGA: 0 to 15
 HS: 0 to 15 ST: 0 to 15 SHS: 0 to 12  | 
GIGA: 0 to 15
 HS: 0 to 15 ST: 0 to 15 SHS: 0 to 12  | 
Soda glass with
 reflection factor of 7%  | 
E32-L16-N 2M | 
![]()  | 
R10 | GIGA: 0 to 4
 HS: 0 to 4 ST: 0 to 4 SHS: 0 to 4  | 
GIGA: 0 to 4
 HS: 0 to 4 ST: 0 to 4 SHS: 0 to 4  | 
(5 μm dia./
 2 μm dia.)  | 
E32-L24S 2M | |
| Side-View | 
![]()  | 
GIGA: 5.4 to 9
 HS: 5.4 to 9 ST: 5.4 to 9 SHS: 5.4 to 9 (Center 7.2)  | 
GIGA: 5.4 to 9
 HS: 5.4 to 9 ST: 5.4 to 9 SHS: 5.4 to 9 (Center 7.2)  | 
E32-L25L 2M | ||
            Note 1. If operation is affected by the background, perform power tuning or use the ECO Mode to decrease the incident
    light level.
   2. The following mode names and response times apply to the modes given in the Sensing distance column.
    [E3X-ZV] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms),
    and SHS: Super-high-speed mode (50 μs)
    [E3NX-FA] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms),
    and SHS: Super-high-speed mode (30 μs)
   3. The values for the minimum sensing object are reference values that indicate values obtained in standard mode
    with the sensing distance and sensitivity set to the optimum values.
    The first value is for the E3X-ZV and the second value is for the E3NX-FA.
   4. The sensing distances for Reflective Fiber Units are for white paper.
   5. The sensing distances for the E3NX-FA are values for E3NX-FA[] devices. The distance for E3NX-FAH[] infrared
    models varies.
   6. The E3X-HD Series offers the same sensing distance as the E3X-ZV.
        
| Type | Appearance
 (mm)  | 
Bending
 radius of cable  | 
Sensing distance (mm) | Optical axis
 diameter (minimum sensing object)  | 
Models | ||
|---|---|---|---|---|---|---|---|
| Features | Size | E3X-ZV | E3NX-FA | ||||
| Film
 detection *  | 
M6 |  
IP50  | 
Flexible,
 R2  | 
GIGA: 1,350
 HS: 1,000 ST: 1,200 SHS: 550  | 
GIGA: 2,020
 HS: 1,500 ST: 1,800 SHS: 550  | 
- | E32-LR11NP 2M
 + E39-RP1  | 
| Square | - |  
IP66  | 
R25 | GIGA: 150 to 1,500
 HS: 150 to 1,500 ST: 150 to 1,500 SHS: 150 to 1,500  | 
GIGA: 150 to 1,500
 HS: 150 to 1,500 ST: 150 to 1,500 SHS: 150 to 1,500  | 
(0.2 dia./
 0.07 dia.)  | 
E32-R16 2M | 
| Threaded
 Models  | 
M6 |  
IP67  | 
R10 | GIGA: 10 to 250
 HS: 10 to 250 ST: 10 to 250 SHS: 10 to 250  | 
GIGA: 10 to 370
 HS: 10 to 370 ST: 10 to 370 SHS: 10 to 250  | 
(0.1 dia./
 0.03 dia.)  | 
E32-R21 2M | 
            * This effect may not be as strong for some films. Check suitability beforehand.
Note 1. Objects with a high reflection factor may cause the Fiber Sensor to detect reflected light as incident light.
    Also, stable detection may not be possible for transparent objects.
Check suitability beforehand.
   2. The following mode names and response times apply to the modes given in the Sensing distance column.
    [E3X-ZV] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms),
         and SHS: Super-high-speed mode (50 μs)
    [E3NX-FA] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms),
          and SHS: Super-high-speed mode (30 μs)
   3. The values for the minimum sensing object are reference values that indicate values obtained in standard mode
    with the sensing distance and sensitivity set to the optimum values.
    The first value is for the E3X-ZV and the second value is for the E3NX-FA.
   4. The sensing distances for the E3NX-FA are values for E3NX-FA[] devices. The distance for E3NX-FAH[] infrared
    models varies.
   5. The E3X-HD Series offers the same sensing distance as the E3X-ZV.
        
| Type | Appearance
 (mm)  | 
Bending
 radius of cable  | 
Sensing distance (mm) | Standard
 sensing object (minimum sensing object)  | 
Models | ||
|---|---|---|---|---|---|---|---|
| Features | Sensing
 direction  | 
E3X-ZV | E3NX-FA | ||||
| Small
 size  | 
Flat-
 View  | 
![]()  | 
R10 | GIGA: 0 to 4
 HS: 0 to 4 ST: 0 to 4 SHS: 0 to 4  | 
GIGA: 0 to 4
 HS: 0 to 4 ST: 0 to 4 SHS: 0 to 4  | 
(5 μm dia./
 2 μm dia.)  | 
E32-L24S 2M | 
| Standard | 
![]()  | 
R25 | GIGA: 0 to 15
 HS: 0 to 15 ST: 0 to 15 SHS: 0 to 12  | 
GIGA: 0 to 15
 HS: 0 to 15 ST: 0 to 15 SHS: 0 to 12  | 
Soda glass with
 reflection factor of 7%  | 
E32-L16-N 2M | |
| Glass-
 substrate alignment, 70°C  | 
![]()  | 
GIGA: 10 to 20
 HS: 10 to 20 ST: 10 to 20 SHS: -  | 
GIGA: 10 to 20
 HS: 10 to 20 ST: 10 to 20 SHS: -  | 
E32-A08 2M * | |||
| Standard
 long distance  | 
![]()  | 
GIGA: 12 to 30
 HS: 12 to 30 ST: 12 to 30 SHS: -  | 
GIGA: 12 to 30
 HS: 12 to 30 ST: 12 to 30 SHS: -  | 
E32-A12 2M | |||
| Side
 View form  | 
Side-
 View  | 
![]()  | 
R10 | GIGA: 5.4 to 9
 HS: 5.4 to 9 ST: 5.4 to 9 SHS: 5.4 to 9 (Center 7.2)  | 
GIGA: 5.4 to 9
 HS: 5.4 to 9 ST: 5.4 to 9 SHS: 5.4 to 9 (Center 7.2)  | 
(5 μm dia./
 2 μm dia.)  | 
E32-L25L 2M | 
| Glass-
 substrate Mapping, 70°C  | 
Top-
 View  | 
![]()  | 
R25 | GIGA: 15 to 38
 HS: 15 to 38 ST: 15 to 38 SHS: - (Center 25)  | 
GIGA: 15 to 38
 HS: 15 to 38 ST: 15 to 38 SHS: - (Center 25)  | 
End surface of
 soda glass with reflection factor of 7% (t = 0.7 mm, rounded edges)  | 
E32-A09 2M | 
            * If operation is affected by the background, perform power tuning to decrease the incident light level.
Note 1. The following mode names and response times apply to the modes given in the Sensing distance column.
    [E3X-ZV] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms),
         and SHS: Super-high-speed mode (50 μs)
    [E3NX-FA] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms),
          and SHS: Super-high-speed mode (30 μs)
   2. The values for the minimum sensing object are reference values that indicate values obtained in standard mode with the
    sensing distance and sensitivity set to the optimum values.
    The first value is for the E3X-ZV and the second value is for the E3NX-FA.
   3. The sensing distances for Reflective Fiber Units are for white paper.
   4. The sensing distances for the E3NX-FA are values for E3NX-FA[] devices. The distance for E3NX-FAH[] infrared
    models varies.
   5. The E3X-HD Series offers the same sensing distance as the E3X-ZV.
        
| Type | Sensing
 direction  | 
Appearance
 (mm)  | 
Bending
 radius of cable  | 
Sensing distance (mm) | Optical axis
 diameter (minimum sensing object)  | 
Models | |
|---|---|---|---|---|---|---|---|
| E3X-ZV | E3NX-FA | ||||||
| Oil-
 resistant  | 
Right-
 Angle  | 
 
IP68  | 
Flexible,
 R1  | 
GIGA: 4,000 *1
 HS: 4,000 *1 ST: 4,000 *1 SHS: 2,200  | 
GIGA: 4,000 *1
 HS: 4,000 *1 ST: 4,000 *1 SHS: 2,200  | 
4 dia.
 (0.1 dia./ 0.03 dia.)  | 
E32-T11NF 2M | 
 
IP68G  | 
Flexible,
 R1  | 
GIGA: 2,200
 HS: 730 ST: 1,100 SHS: 270  | 
GIGA: 3,300
 HS: 1,100 ST: 1,600 SHS: 270  | 
2 dia.
 (0.1 dia./ 0.03 dia.)  | 
E32-T11NFS 2M | ||
| Chemical/
 oil resistant  | 
Top-
 View  | 
 
IP67  | 
R40 | GIGA: 4,000 *1
 HS: 4,000 *1 ST: 4,000 *1 SHS: 1,600  | 
GIGA: 4,000 *1
 HS: 4,000 *1 ST: 4,000 *1 SHS: 1,600  | 
4 dia.
 (0.1 dia./ 0.03 dia.)  | 
E32-T12F 2M | 
 
IP67  | 
R4 | GIGA: 4,000 *1
 HS: 2,600 ST: 4,000 *1 SHS: 1,000  | 
GIGA: 4,000 *1
 HS: 3,900 ST: 4,000 *1 SHS: 1,000  | 
E32-T11F 2M | |||
| Side-
 view  | 
 
IP67  | 
R40 | GIGA: 1,400
 HS: 500 ST: 800 SHS: 200  | 
GIGA: 2,100
 HS: 750 ST: 1,200 SHS: 200  | 
3 dia.
 (0.1 dia./ 0.03 dia.)  | 
E32-T14F 2M | |
| Chemical/
 oil resistant 150°C *2  | 
Top-
 View  | 
 
IP67  | 
GIGA: 4,000 *1
 HS: 1,800 ST: 2,800 SHS: 700  | 
GIGA: 4,000 *1
 HS: 2,700 ST: 4,000 *1 SHS: 700  | 
4 dia.
 (0.1 dia./ 0.03 dia.)  | 
E32-T51F 2M | |
            *1 The optical fiber is 2 m long on each side, so the sensing distance is 4,000 mm.
*2 For continuous operation, use the Fiber Unit between −40 and 130°C.
*3. The IP68G is the degree of protection which is defined according to the JIS (Japanese Industrial Standards). The IP68 indicates the same level of protection as defined by the IEC, and the G indicates that a device has resistance to oil. Passed OMRON's Oil-resistant Component Evaluation Standards (OMRON's own durability evaluation standards)
(Cutting oil type: specified in JIS K 2241:2000; Temperature: 35°C max.)
Note1. The sensing distances for the E3NX-FA are values for E3NX-FA[] devices. The distance for E3NX-FAH[] infrared
    models varies.
  2. The E3X-HD Series offers the same sensing distance as the E3X-ZV.
        
| Type | Sensing
 direction  | 
Appearance
 (mm)  | 
Bending
 radius of cable  | 
Sensing distance (mm) | Standard
 sensing object (minimum sensing object)  | 
Models | |
|---|---|---|---|---|---|---|---|
| E3X-ZV | E3NX-FA | ||||||
| Semiconductors:
 Cleaning, developing, and etching, 60°C  | 
Top-
 View  | 
![]()  | 
R40 | 8 to 20 mm from tip of lens
 (Recommended sensing distance: 11 mm) 19 to 31 mm from center of mounting hole A (Recommended sensing distance: 22 mm)  | 
Glass
 (t=0.7 mm)  | 
E32-L11FP 2M | |
| Semiconductors:
 Resist stripping, 85°C  | 
![]()  | 
8 to 20 mm from tip of lens
 (Recommended sensing distance: 11 mm) 32 to 44 mm from center of mounting hole A (Recommended sensing distance: 35 mm)  | 
E32-L11FS 2M | ||||
| Chemical/
 oil resistant  | 
![]()  | 
GIGA: -
 HS: 130 ST: 190 SHS: 60  | 
GIGA: -
 HS: 190 ST: 280 SHS: 60  | 
(5 μm dia./
 2 μm dia.)  | 
E32-D12F 2M | ||
| Only cable:
 chemical resistant  | 
![]()  | 
R4 | GIGA: 840
 HS: 240 ST: 350 SHS: 100  | 
GIGA: 1,260
 HS: 360 ST: 520 SHS: 100  | 
E32-D11U 2M | ||
            Note 1. The following mode names and response times apply to the modes given in the Sensing distance column.
    [E3X-ZV] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms),
         and SHS: Super-high-speed mode (50 μs)
    [E3NX-FA] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms),
          and SHS: Super-high-speed mode (30 μs)
   2. The values for the minimum sensing object are reference values that indicate values obtained in standard mode
    with the sensing distance and sensitivity set to the optimum values.
    The first value is for the E3X-ZV and the second value is for the E3NX-FA.
   3. The sensing distances for Reflective Fiber Units are for white paper.
   4. The sensing distances for the E3NX-FA are values for E3NX-FA[] devices. The distance for E3NX-FAH[] infrared
    models varies.
   5. E3X-HD Series offers the same sensing distance as the E3X-ZV.
        
| Size | Appearance
 (mm)  | 
Bending
 radius of cable  | 
Sensing distance (mm) | Optical axis
 diameter (minimum sensing object)  | 
Models | |
|---|---|---|---|---|---|---|
| E3X-ZV | E3NX-FA | |||||
| 1.5 dia. | 
![]()  | 
Bend-resistant,
 R4  | 
GIGA: 680
 HS: 220 ST: 400 SHS: 90  | 
GIGA: 1,020
 HS: 330 ST: 600 SHS: 90  | 
0.5 dia.
 (5 μm dia./ 2 μm dia.)  | 
E32-T22B 2M | 
| M3 | 
![]()  | 
E32-T21 2M | ||||
| M4 | 
![]()  | 
GIGA: 2,500
 HS: 900 ST: 1,350 SHS: 360  | 
GIGA: 3,750
 HS: 1,350 ST: 2,020 SHS: 360  | 
1 dia.
 (5 μm dia./ 2 μm dia.)  | 
E32-T11 2M | |
| Square | 
![]()  | 
GIGA: 500
 HS: 170 ST: 300 SHS: 70  | 
GIGA: 750
 HS: 250 ST: 450 SHS: 70  | 
0.5 dia.
 (5 μm dia./ 2 μm dia.)  | 
E32-T25XB 2M | |
            Note 1. The following mode names and response times apply to the modes given in the Sensing distance column.
    [E3X-ZV] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms),
         and SHS: Super-high-speed mode (50 μs)
    [E3NX-FA] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms),
          and SHS: Super-high-speed mode (30 μs)
   2. The values for the minimum sensing object are reference values that indicate values obtained in standard mode
    with the sensing distance and sensitivity set to the optimum values.
    The first value is for the E3X-ZV and the second value is for the E3NX-FA.
   3. The sensing distances for the E3NX-FA are values for E3NX-FA[] devices. The distance for E3NX-FAH[] infrared
    models varies.
   4. The E3X-HD Series offers the same sensing distance as the E3X-ZV.
        
Insert the fiber cable into the protective tube to prevent breaking by snagging or shock.
| Applicable Fiber Units | Model | Quantity | 
|---|---|---|
| E32-T11R 2M/E32-T11 2M/E32-LT11 2M/E32-LT11R 2M/
 E32-T51R 2M/E32-T51 2M  | 
									E39-F32C 1M | 2 pieces | 
* This Tube cannot be used if a Lens Unit is being used.
| Size | Appearance
 (mm)  | 
Bending
 radius of cable  | 
Sensing distance (mm) | Optical axis
 diameter (minimum sensing object)  | 
Models | |
|---|---|---|---|---|---|---|
| E3X-ZV | E3NX-FA | |||||
| 1.5 dia. | 
![]()  | 
Bend-resistant,
 R4  | 
GIGA: 140
 HS: 40 ST: 60 SHS: 16  | 
GIGA: 210
 HS: 60 ST: 90 SHS: 16  | 
(5 μm dia./
 2 μm dia.)  | 
E32-D22B 2M | 
| M3 | 
![]()  | 
E32-D21 2M | ||||
| 3 dia. | 
![]()  | 
GIGA: 300
 HS: 90 ST: 140 SHS: 40  | 
GIGA: 450
 HS: 130 ST: 210 SHS: 40  | 
E32-D221B 2M | ||
| M4 | 
![]()  | 
E32-D21B 2M | ||||
| M6 | 
![]()  | 
GIGA: 840
 HS: 240 ST: 350 SHS: 100  | 
GIGA: 1,260
 HS: 360 ST: 520 SHS: 100  | 
E32-D11 2M | ||
| Square | 
![]()  | 
GIGA: 240
 HS: 60 ST: 100 SHS: 30  | 
GIGA: 360
 HS: 90 ST: 150 SHS: 30  | 
E32-D25XB 2M | ||
            Note 1. The following mode names and response times apply to the modes given in the Sensing distance column.
    [E3X-ZV] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms),
         and SHS: Super-high-speed mode (50 μs)
    [E3NX-FA] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms),
          and SHS: Super-high-speed mode (30 μs)
   2. The values for the minimum sensing object are reference values that indicate values obtained in standard mode
    with the sensing distance and sensitivity set to the optimum values.
   3. The first value is for the E3X-ZV and the second value is for the E3NX-FA.The sensing distances for Reflective
    Fiber Units are for white paper.
   4. The sensing distances for the E3NX-FA are values for E3NX-FA[] devices. The distance for E3NX-FAH[] infrared
    models varies.
   5. The E3X-HD Series offers the same sensing distance as the E3X-ZV.
        
Insert the fiber cable into the protective tube to prevent breaking by snagging or shock.
| Applicable Fiber Units | Models | Quantity | 
|---|---|---|
| E32-D21R 2M/E32-C31 2M/E32-D21 2M | E39-F32A 1M | 1 piece | 
| E32-D211R 2M/E32-D21B 2M | E39-F32C 1M | 2 pieces | 
| E32-D11R 2M/E32-CC200 2M/E32-D11 2M/E32-D51R 2M/E32-D51 2M | E39-F32D 1M | 1 piece | 
* This Tube cannot be used if a Lens Unit is being used.
| Heat-
 resistant temperature  | 
Appearance
 (mm)  | 
Bending
 radius of cable  | 
Sensing distance (mm) | Optical axis
 diameter (minimum sensing object)  | 
Models | |
|---|---|---|---|---|---|---|
| E3X-ZV | E3NX-FA | |||||
| 100℃ *1 |  
IP50  | 
Flexible,
 R2  | 
GIGA: 1,600
 HS: 560 ST: 800 SHS: 225  | 
GIGA: 2,400
 HS: 840 ST: 1,200 SHS: 225  | 
1 dia.
 (0.1 dia./ 0.03 dia.)  | 
E32-T51R 2M | 
| 150℃ *2 |  
IP67  | 
R35 | GIGA: 2,800
 HS: 1,000 ST: 1,500 SHS: 400  | 
GIGA: 4,000 *5
 HS: 1,500 ST: 2,250 SHS: 400  | 
1.5 dia.
 (0.1 dia./ 0.03 dia.)  | 
E32-T51 2M | 
| 150℃ *2 |  
IP67  | 
R35 | GIGA: 840
 HS: 300 ST: 450 SHS: 120  | 
GIGA: 1,260
 HS: 450 ST: 670 SHS: 120  | 
1.5 dia.
 (0.1 dia./ 0.03 dia.)  | 
E32-T54 2M | 
| 200℃ *3 |  
IP67  | 
R10 | GIGA: 1,000
 HS: 360 ST: 550 SHS: 140  | 
GIGA: 1,500
 HS: 540 ST: 820 SHS: 140  | 
0.7 dia.
 (5 μm dia./ 2 μm dia.)  | 
E32-T81R-S 2M | 
| 200°C |  
IP67  | 
R25 | GIGA: 4,000 *5
 HS: 1,740 ST: 2,600 SHS: 700  | 
GIGA: 4,000 *5
 HS: 2,610 ST: 3,900 SHS: 700  | 
1.7 dia.
 (0.1 dia./ 0.03 dia.)  | 
E32-T84S-S 2M | 
| 300°C |  
IP30  | 
R25 | GIGA: 360
 HS: 120 ST: 190 SHS: 50  | 
GIGA: 540
 HS: 180 ST: 290 SHS: 70  | 
- | E32-T64-2 2M | 
| 350℃ *4 |  
IP67  | 
R25 | GIGA: 1,680
 HS: 600 ST: 900 SHS: 240  | 
GIGA: 2,520
 HS: 900 ST: 1,350 SHS: 240  | 
1 dia.
 (5 μm dia./ 2 μm dia.)  | 
E32-T61-S 2M | 
| 70℃ | - | Standard Fiber Units
 can be used.  | 
||||
            *1 For continuous operation, use the Fiber Unit between −40 to 90°C.
*2 For continuous operation, use the Fiber Unit between −40 to 130°C.
*3 The heat-resistant rating is not the same for all parts of the Fiber Unit. Refer to the dimensions diagrams for details.
*4 The ambient operating temperature for the E32-T61-S 2M is −60 to 350°C.
*5 The optical fiber is 2 m long on each side, so the sensing distance is 4,000 mm.
Note 1. The following mode names and response times apply to the modes given in the Sensing distance column.
    [E3X-ZV] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms),
         and SHS: Super-high-speed mode (50 μs)
    [E3NX-FA] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms),
          and SHS: Super-high-speed mode (30 μs)
   2. The values for the minimum sensing object are reference values that indicate values obtained in standard mode
    with the sensing distance and sensitivity set to the optimum values.
    The first value is for the E3X-ZV and the second value is for the E3NX-FA.
   3. The sensing distances for the E3NX-FA are values for E3NX-FA[] devices. The distance for E3NX-FAH[] infrared
    models varies.
   4. The E3X-HD Series offers the same sensing distance as the E3X-ZV.
        
| Heat-
 resistant temperature  | 
Appearance
 (mm)  | 
Bending
 radius of cable  | 
Sensing distance (mm) | Standard
 sensing object (minimum sensing object)  | 
Models | |
|---|---|---|---|---|---|---|
| E3X-ZV | E3NX-FA | |||||
| 100℃ *1 |  
IP50  | 
Flexible,
 R2  | 
GIGA: 670
 HS: 190 ST: 280 SHS: 80  | 
GIGA: 1,000
 HS: 280 ST: 420 SHS: 80  | 
(5 μm dia./
 2 μm dia.)  | 
E32-D51R 2M | 
| 150℃ *2 |  
IP67  | 
R35 | GIGA: 1,120
 HS: 320 ST: 450 SHS: 144  | 
GIGA: 1,680
 HS: 480 ST: 670 SHS: 144  | 
E32-D51 2M | |
| 200℃ *3 |  
IP67  | 
R10 | GIGA: 420
 HS: 120 ST: 180 SHS: 54  | 
GIGA: 630
 HS: 180 ST: 270 SHS: 54  | 
E32-D81R-S 2M | |
| 300°C *3 |  
IP30  | 
R25 | GIGA: 10 to 20
 HS: 10 to 20 ST: 10 to 20 SHS: -  | 
GIGA: 10 to 20
 HS: 10 to 20 ST: 10 to 20 SHS: -  | 
Soda glass with
 reflection factor of 7%  | 
E32-A08H2 2M | 
 
IP50  | 
GIGA: 1 to 5
 HS: 1 to 5 ST: 1 to 5 SHS: -  | 
GIGA: 1 to 5
 HS: 1 to 5 ST: 1 to 5 SHS: -  | 
- | E32-L64 2M | ||
| 200°C *3 |  
IP60  | 
GIGA: 4 to 10
 HS: 4 to 10 ST: 4 to 10 SHS: 4 to 10  | 
GIGA: 4 to 10
 HS: 4 to 10 ST: 4 to 10 SHS: 4 to 10  | 
(5 m dia./
 2 m dia.)  | 
E32-L86 2M | |
| 300°C *3 |  
IP40  | 
GIGA: 20 to 30
 HS: 20 to 30 ST: 20 to 30 SHS: -  | 
GIGA: 20 to 30
 HS: 20 to 30 ST: 20 to 30 SHS: -  | 
End surface of
 soda glass with eflection factor of 7% (t = 0.7 mm, rounded edges)  | 
E32-A09H2 2M | |
| 350℃ *3 |  
IP67  | 
GIGA: 420
 HS: 120 ST: 180 SHS: 54  | 
GIGA: 630
 HS: 180 ST: 270 SHS: 54  | 
(5 μm dia./
 2 μm dia.)  | 
E32-D611-S 2M | |
![]()  | 
E32-D61-S 2M | |||||
| 400℃ *3 | Sleeve bending
 radius : 10 mm ![]()  | 
GIGA: 280
 HS: 80 ST: 120 SHS: 36  | 
GIGA: 420
 HS: 120 ST: 180 SHS: 36  | 
E32-D73-S 2M | ||
| 70℃ | - | Standard Fiber Units
 can be used.  | 
||||
            *1 For continuous operation, use the Fiber Unit between −40 to 90°C.
*2 For continuous operation, use the Fiber Unit between −40 to 130°C.
*3 The heat-resistant rating is not the same for all parts of the Fiber Unit. Refer to the dimensions diagrams for details.
Note 1. The following mode names and response times apply to the modes given in the Sensing distance column.
    [E3X-ZV] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms),
         and SHS: Super-high-speed mode (50 μs)
    [E3NX-FA] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms),
          and SHS: Super-high-speed mode (30 μs)
   2. The values for the minimum sensing object are reference values that indicate values obtained in standard mode
    with the sensing distance and sensitivity set to the optimum values.
    The first value is for the E3X-ZV and the second value is for the E3NX-FA.
   3. The sensing distances for Reflective Fiber Units are for white paper.
   4. The sensing distances for the E3NX-FA are values for E3NX-FA[] devices. The distance for E3NX-FAH[] infrared
    models varies.
   5. E3X-HD Series offers the same sensing distance as the E3X-ZV.
        
| Type | Sensing
 width  | 
Appearance
 (mm)  | 
Bending
 radius of cable  | 
Sensing distance (mm) | Optical axis
 diameter (minimum sensing object)  | 
Models | |
|---|---|---|---|---|---|---|---|
| E3X-ZV | E3NX-FA | ||||||
| Area | 11 mm |  
IP50  | 
Flexible,
 R1  | 
GIGA: 3,100
 HS: 1,120 ST: 1,700 SHS: 440  | 
GIGA: 4,000 *1
 HS: 1,680 ST: 2,550 SHS: 440  | 
(0.2 dia./
 0.07 dia.) *2  | 
E32-T16PR 2M | 
 
IP50  | 
GIGA: 2,750
 HS: 960 ST: 1,500 SHS: 380  | 
GIGA: 4,000 *1
 HS: 1,440 ST: 2,250 SHS: 380  | 
E32-T16JR 2M | ||||
 
IP40  | 
GIGA: 40 to 420
 HS: 40 to 420 ST: 40 to 420 SHS: 40 to 160  | 
GIGA: 40 to 630
 HS: 40 to 630 ST: 40 to 630 SHS: 40 to 240  | 
- | E32-A13 2M | |||
| 30 mm |  
IP50  | 
GIGA: 4,000 *1
 HS: 1,700 ST: 2,600 SHS: 680  | 
GIGA: 4,000 *1
 HS: 2,550 ST: 3,900 SHS: 680  | 
(0.3 dia./
 0.1 dia.) *2  | 
E32-T16WR 2M | ||
| Array | 10 mm |  
IP50  | 
R5 | GIGA: 10
 HS: 10 ST: 10 SHS: 10  | 
GIGA: 10
 HS: 10 ST: 10 SHS: 10  | 
0.5 dia. | E32-G16 2M | 
            *1. The optical fiber is 2 m long on each side, so the sensing distance is 4,000 mm.
*2. The values for the minimum sensing object were obtained for detection in the sensing area with the sensing distance
  set to 300 mm.
  (The values are for a stationary sensing object.)
  The first value is for the E3X-ZV and the second value is for the E3NX-FA.
Note 1. The sensing distances for the E3NX-FA are values for E3NX-FA[] devices. The distance for E3NX-FAH[] infrared
    models varies.
   2. The E3X-HD Series offers the same sensing distance as the E3X-ZV.
        
| Type | Sensing
 width  | 
Appearance
 (mm)  | 
Bending
 radius of cable  | 
Sensing distance (mm) | Optical axis
 diameter (minimum sensing object)  | 
Models | |
|---|---|---|---|---|---|---|---|
| E3X-ZV | E3NX-FA | ||||||
| Array | 11 mm | 
![]()  | 
Bend-
 resistant, R4  | 
GIGA: 700
 HS: 200 ST: 300 SHS: 90  | 
GIGA: 1,050
 HS: 300 ST: 450 SHS: 90  | 
(5 μm dia./
 2 μm dia.)  | 
E32-D36P1 2M | 
            Note 1. The following mode names and response times apply to the modes given in the Sensing distance column.
    [E3X-ZV] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms),
         and SHS: Super-high-speed mode (50 μs)
    [E3NX-FA] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms),
          and SHS: Super-high-speed mode (30 μs)
   2. The values for the minimum sensing object are reference values that indicate values obtained in standard mode
    with the sensing distance and sensitivity set to the optimum values.
    The first value is for the E3X-ZV and the second value is for the E3NX-FA.
   3. The sensing distances for the E3NX-FA are values for E3NX-FA[] devices. The distance for E3NX-FAH[] infrared
    models varies.
   4. E3X-HD Series offers the same sensing distance as the E3X-ZV.
        
| Detection
 scheme  | 
										Tube
 diameter  | 
										Features | Appearance
 (mm)  | 
										Bending
 radius of cable  | 
										Applicable range | Optical
 axis diameter (minimum sensing object)  | 
										Models | 
|---|---|---|---|---|---|---|---|
| Tube-
 mounting  | 
										3.2, 6.4
 and 9.5 dia.  | 
										Resistant to
 bubbles and droplets Residual quantity detection  | 
										
											![]()  | 
										Bend-
 resistant, R4  | 
										Applicable tube:
 Transparent tube with a diameter of 3.2, 6.4, or 9.5 dia. and a recommended wall thickness of 1 mm  | 
										- | E32-A01 5M | 
| 8 to
 10 dia.  | 
										Ideal for
 mounting at multilevels  | 
										
											![]()  | 
										R10 | Applicable tube:
 Transparent tube with a diameter of 8 to 10 dia. and a recommended wall thickness of 1 mm  | 
										- | E32-L25T 2M | |
| No
 restric- tions  | 
										Usable on
 large diameter tubes Resistant to bubbles and droplets  | 
										
											![]()  | 
										R4 | Applicable tube:
 Transparent tube (no restrictions on diameter)  | 
										- | E32-D36T 2M | |
| Liquid
 contact (heat- resistant up to 200°C)  | 
										- | - | 
											![]()  | 
										R40
 R25 *3  | 
										Liquid-contact Type
 *1  | 
										- | E32-D82F1 4M | 
            *1. If you want to change the amount of received light, please Refer to the Instruction Sheet of the Fiber Amplifier used.
*2. The applicable range is the same whether an E3X-ZV series or E3NX-FA series is used.
  This does not include E3NX-FAH[] infrared models varies.
  When using a Fiber Amplifier Unit in giga-power mode, level detection may not work depending on the tube diameter.
  Make sure to confirm operation with the actual tube.
*3. The bending radius of the sensing section (except for the unbendable section) is 40 mm, and the bending radius of the
  fiber is 25 mm.
        
| Type | Heat-
 resistant temperature  | 
Appearance
 (mm)  | 
Bending
 radius of cable  | 
Sensing distance (mm) | Optical axis
 diameter (minimum sensing object)  | 
Models | |
|---|---|---|---|---|---|---|---|
| E3X-ZV | E3NX-FA | ||||||
| Vacuum
 side  | 
120℃ | 
![]()  | 
R30 | GIGA: 720
 HS: 260 ST: 400 SHS: 100  | 
GIGA: 1,080
 HS: 390 ST: 600 SHS: 100  | 
1.2 dia.
 (10 μm dia./ 4 μm dia.)  | 
E32-T51V 1M | 
![]()  | 
GIGA: 2,000 *
 HS: 1,360 ST: 2,000 SHS: 520  | 
GIGA: 2,000 *
 HS: 2,000 * ST: 2,000 * SHS: 520  | 
4 dia.
 (0.1 dia./ 0.03 dia.)  | 
E32-T51V 1M
 + E39-F1V  | 
|||
| 200℃ | 
![]()  | 
R25 | GIGA: 1,760
 HS: 640 ST: 950 SHS: 260  | 
GIGA: 2,000 *
 HS: 960 ST: 1,420 SHS: 260  | 
2 dia.
 (0.1 dia./ 0.03 dia.)  | 
E32-T84SV 1M | |
| Atmospheric
 pressure side  | 
70℃ | 
![]()  | 
- | - | - | E32-T10V 2M | |
            * The optical fiber is 2 m long on each side, so the sensing distance is 4,000 mm.
Note 1. The following mode names and response times apply to the modes given in the Sensing distance column.
    [E3X-ZV] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms),
         and SHS: Super-high-speed mode (50 μs)
    [E3NX-FA] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms),
          and SHS: Super-high-speed mode (30 μs)
   2. The values for the minimum sensing object are reference values that indicate values obtained in standard mode
    with the sensing distance and sensitivity set to the optimum values.
    The first value is for the E3X-ZV and the second value is for the E3NX-FA.
   3. The sensing distances for the E3NX-FA are values for E3NX-FA[] devices. The distance for E3NX-FAH[] infrared
    models varies.
   4. The E3X-HD Series offers the same sensing distance as the E3X-ZV.
        
| Appearance | Type | Models | 
|---|---|---|
											![]()  | 
										4-channel flange | E32-VF4 | 
											![]()  | 
										1-channel flange | E32-VF1 | 
| Application | Ambient
 temper- ature  | 
Appearance
 (mm)  | 
Bending
 radius of cable  | 
Sensing distance (mm) | Standard
 sensing object (minimum sensing object)  | 
Models | |
|---|---|---|---|---|---|---|---|
| E3X-ZV | E3NX-FA | ||||||
| Glass
 presence detection  | 
70℃ | 
![]()  | 
R25 | GIGA: 0 to 15
 HS: 0 to 15 ST: 0 to 15 SHS: 0 to 12  | 
GIGA: 0 to 15
 HS: 0 to 15 ST: 0 to 15 SHS: 0 to 12  | 
Soda glass
 with reflection factor of 7%  | 
E32-L16-N 2M
 *1  | 
| Glass-
 substrate Alignment  | 
![]()  | 
GIGA: 10 to 20
 HS: 10 to 20 ST: 10 to 20 SHS: -  | 
GIGA: 10 to 20
 HS: 10 to 20 ST: 10 to 20 SHS: -  | 
E32-A08 2M
 *1  | 
|||
| 300℃ | 
![]()  | 
E32-A08H2 2M
 *1  | 
|||||
| 70℃ | 
![]()  | 
GIGA: 12 to 30
 HS: 12 to 30 ST: 12 to 30 SHS: -  | 
GIGA: 12 to 30
 HS: 12 to 30 ST: 12 to 30 SHS: -  | 
E32-A12 2M | |||
| Mapping of
 glass substrates  | 
![]()  | 
GIGA: 15 to 38
 HS: 15 to 38 ST: 15 to 38 SHS: - (Center 25)  | 
GIGA: 15 to 38
 HS: 15 to 38 ST: 15 to 38 SHS: - (Center 25)  | 
End surface
 of soda glass with reflection factor of 7% (t = 0.7 mm, rounded edges)  | 
E32-A09 2M | ||
| 300°C
 *2  | 
![]()  | 
GIGA: 20 to 30
 HS: 20 to 30 ST: 20 to 30 SHS: - (Center 25)  | 
GIGA: 20 to 30
 HS: 20 to 30 ST: 20 to 30 SHS: - (Center 25)  | 
E32-A09H2 2M | |||
| Wet
 processes (Cleaning, Resist developing, and etching)  | 
60℃ | 
![]()  | 
R40 | 8 to 20 mm from tip of lens
 (Recommended sensing distance: 11 mm) 19 to 31 mm from center of mounting hole A (Recommended sensing distance: 22 mm)  | 
Glass
 (t=0.7mm)  | 
E32-L11FP 2M | |
| Wet
 processes (Resist stripping)  | 
85℃ | 
![]()  | 
8 to 20 mm from tip of lens
 (Recommended sensing distance: 11 mm) 32 to 44 mm from center of mounting hole A (Recommended sensing distance: 35 mm)  | 
E32-L11FS 2M | |||
            *1 If operation is affected by the background, perform power tuning to decrease the incident light level.
*2 The maximum allowable temperature is not the same for all parts of the Fiber Unit. Refer to the dimensions
  diagrams for details.
  Must not be repeatedly subject to rapid temperature changes.
Note 1. The following mode names and response times apply to the modes given in the Sensing distance column.
    [E3X-ZV] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms),
         and SHS: Super-high-speed mode (50 μs)
    [E3NX-FA] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms),
          and SHS: Super-high-speed mode (30 μs)
   2. The sensing distances for the E3NX-FA are values for E3NX-FA[] devices. The distance for E3NX-FAH[] infrared
    models varies.
   3. The E3X-HD Series offers the same sensing distance as the E3X-ZV.
        
| Appli-
 cation  | 
Ambient
 temper- ature  | 
Aper-
 ture angle  | 
Appearance
 (mm)  | 
Bending
 radius of cable  | 
Sensing distance (mm) | Optical
 axis diameter (minimum sensing object)  | 
Models | |
|---|---|---|---|---|---|---|---|---|
| E3X-ZV | E3NX-FA | |||||||
| Wafer
 Mapping  | 
70°C | 1.5° |  
Thickness: 3 mm IP50  | 
Flexible,
 R1  | 
GIGA: 3,220
 HS: 1,200 ST: 1,780 SHS: 500  | 
GIGA: 4,000 *
 HS: 1,800 ST: 2,670 SHS: 500  | 
2 dia.
 (0.1 dia./ 0.03 dia.)  | 
E32-A03 2M | 
 
IP50  | 
R10 | E32-A03-1 2M | ||||||
 
IP50  | 
R10 | GIGA: 2,500
 HS: 940 ST: 1,400 SHS: 380  | 
GIGA: 2,500
 HS: 940 ST: 1,400 SHS: 380  | 
- | E32-A03-2 2M | |||
| 3.4° |  
Thickness: 2 mm IP50  | 
R10 | GIGA: 1,280
 HS: 450 ST: 680 SHS: 200  | 
GIGA: 1,920
 HS: 670 ST: 1,020 SHS: 200  | 
1.2 dia.
 (0.1 dia./ 0.03 dia.)  | 
E32-A04 2M | ||
 
IP50  | 
R10 | GIGA: 1,280
 HS: 450 ST: 680 SHS: 200  | 
GIGA: 1,920
 HS: 670 ST: 1,020 SHS: 200  | 
E32-A04-1 2M | ||||
 
IP50  | 
R10 | GIGA: 960
 HS: 335 ST: 510 SHS: 150  | 
GIGA: 1,440
 HS: 500 ST: 760 SHS: 150  | 
- | E32-A04-8 2M | |||
| 4° |  
IP50  | 
Flexible,
 R1  | 
GIGA: 4,000 *
 HS: 1,460 ST: 2,200 SHS: 580  | 
GIGA: 4,000 *
 HS: 2,190 ST: 3,300 SHS: 580  | 
2 dia.
 (0.1 dia./ 0.03 dia.)  | 
E32-T24SR 2M | ||
| R10 | GIGA: 4,000 *
 HS: 1,740 ST: 2,600 SHS: 700  | 
GIGA: 4,000 *
 HS: 2,610 ST: 3,900 SHS: 700  | 
E32-T24S 2M | |||||
            * The optical fiber is 2 m long on each side, so the sensing distance is 4,000 mm.
Note 1. The following mode names and response times apply to the modes given in the Sensing distance column.
    [E3X-ZV] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms),
         and SHS: Super-high-speed mode (50 μs)
    [E3NX-FA] GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms),
          and SHS: Super-high-speed mode (30 μs)
   2. The values for the minimum sensing object are reference values that indicate values obtained in standard mode
    with the sensing distance and sensitivity set to the optimum values.
    The first value is for the E3X-ZV and the second value is for the E3NX-FA.
   3. The sensing distances for the E3NX-FA are values for E3NX-FA[] devices. The distance for E3NX-FAH[] infrared
    models varies.
   4. The E3X-HD Series offers the same sensing distance as the E3X-ZV.
        
last update: October 6, 2025