Page top

Industrial Automation

Industrial Automation

Discontinued On Mar. 2015

D4GL, D4GL-SK10-LK[]

Guard Lock Safety-door Switch/Slide key

D4GL, D4GL-SK10-LK[]

Vertically Mounting Guard Lock Safety-door Switch Ideal for Limited Installation Space

* Information in this page is a reference that you created on the basis of information in the product catalog before the end of production, may be different from the current situation, such as goods for / supported standards options / price / features of the product. Before using, please check the compatibility and safety system.

Standards and EC Directives

Conforms to the following EC Directives:

• Machinery Directive
• Low Voltage Directive
• EN1088
• EN60204-1
• GS-ET-19

Certified Standards

Standard type

Certification body Standard File No.
TÜV SÜD EN60947-5-1 (certified direct opening) Consult your OMRON representative for details.
UL *1 UL508, CSA C22.2 No.14 E76675
CQC (CCC) GB14048.5 2003010305064264
KOSHA *2 EN 60947-5-1 Consult your OMRON representative for details.
*1. Certification for CSA C22.2 No. 14 is authorized by the UL mark.
*2. Only certain models have been certified.

Metallic release key type

Certification body Standard File No.
TÜV SÜD EN60947-5-1 (certified direct opening) Consult your OMRON representative for details.
KOSHA EN 60947-5-1 Consult your OMRON representative for details.

Certified Standard Ratings

TÜV (EN60947-5-1), CCC (GB14048.5)

Utilization category AC-15 DC-13
Rated operating current (Ie) 0.75 A 0.27 A
Rated operating voltage (Ue) 240 V 250 V
Note: Use a 10 A fuse type gI or gG that conforms to IEC60269 as a short-circuit protection device.

UL/CSA (UL508, CSA C22.2 No. 14)

C300

Rated voltage Carry current Current (A) Volt-amperes (VA)
Make Break Make Break
120 VAC
240 VAC
2.5 A 15
7.5
1.5
0.75
1,800 180

Q300

Rated voltage Carry current Current (A) Volt-amperes (VA)
Make Break Make Break
125 VAC
250 VAC
2.5 A 0.55
0.27
0.55
0.27
69 69

Solenoid Coil Characteristics

Type 24 VDC
Rated operating voltage (100% ED) 24 VDC ±10%
Current consumption Approx. 200 mA
Insulation Class B (130°C max.)

Indicator Characteristics

Type LED
Rated voltage 24 VDC
Current leakage Approx. 3 mA
Color (LED) Orange/Green

Characteristics

Degree of protection *1 IP67 (EN60947-5-1)
Durability *2 Mechanical 1,000,000 operations min.
Electrical 500,000 operations min. (4 mA resistive load at 24 VDC)
150,000 operations min. (1 A resistive load at 125 VAC,
2 circuits/4 mA resistive load at 24 VDC, 2 circuits) *3
Operating speed 0.05 to 0.5 m/s
Operating frequency 30 operations/minute max.
Direct opening force *4 60 N min. (EN60947-5-1)
Direct opening travel *4 10 mm min. (EN60947-5-1)
Holding force *5 1,000 N min.
Contact resistance 100 mΩ max.
Minimum applicable load *6 4 mA resistive load at 24 VDC (N-level reference value)
Rated insulation voltage (Ui) 300 V (EN60947-5-1)
Rated frequency 50/60 Hz
Protection against electric shock Class II (double insulation)
Pollution degree (operating environment) 3 (EN60947-5-1)
Impulse
withstand
voltage
(EN60947-5-1)
Between terminals of same polarity 2.5 kV
Between terminals of different
polarity
4 kV
Between solenoid and non-current
carrying metallic parts
0.8 kV
Between other terminals and non-
current carrying metallic parts
4 kV
Insulation resistance 100 MΩ min. (at 500 VDC)
Contact gap 2 × 2 mm min.
Vibration
resistance
Malfunction 10 to 55 Hz, 0.75 mm single amplitude
Shock
resistance
Destruction 1,000 m/s2 min.
Malfunction 300 m/s2 min.
Conditional short-circuit current 100 A (EN60947-5-1)
Conventional free air thermal current (Ith) 2.5 A (EN60947-5-1)
Ambient operations temperature -10 to 55°C (with no icing)
Ambient operations humidity 95% max.
Weight Approx. 400 g (D4GL-1AFA-A)
Note: 1. The above values are initial values.
           2. The Switch contacts can be used with either standard loads or microloads. Once the contacts have been used
                to switch a load, however, they cannot be used to switch smaller loads. The contact surfaces will become
                rough once they have been used and contact reliability for smaller loads may be reduced.
*1. The degree of protection is tested using the method specified by the standard (EN60947-5-1). Confirm that sealing
       properties are sufficient for the operating conditions and environment beforehand. Although the switch box is
       protected from dust or water penetration, do not use the D4GL in places where foreign material may enter through
       the key hole on the head, otherwise Switch damage or malfunctioning may occur.
*2. The durability is for an ambient temperature of 5 to 35°C and an ambient humidity of 40% to 70%. For more details,
       consult your OMRON representative.
*3. Do not pass the 1 A, 125 VAC load through more than 2 circuits.
*4. These figures are minimum requirements for safe operation.
*5. This figure is based on the GS-ET-19 evaluation method.
*6. This value will vary with the switching frequency, environment, and reliability level. Confirm that correct operation is
       possible with the actual load beforehand.