Industrial Automation|

Australia

Clearance Centre

Sitemap

Contact

OMRON IA Global

 
Submit Enquiry
View Applications

Member Area

Find out information related to F3SJ.

Catalogs/Manuals

CAD Drawings

 


Related Contents

Product News

Selection Guide

Standards Certification

RoHS Compliant Status

Select Country

 

Product Information

Product Index :: Safety Solutions :: Safety Sensors

F3SJ Safety Light Curtain

 

F3SJ Series Safety Light Curtain

Download Product Brochure

* Ordering information
* Specifications
* Configurations
* Dimensions, and etc

 

  can be found in our PDF brochure.
 

 

 

Highly Functional Safety Light Curtain that Supports Finger Protection and Special Applications

  • Support finger protection, and complex blanking and muting functions.

  • Setting parameters and checking system status made easy using support software and setting console.

  • Conform to the latest Type 4, PLe and SIL3 requirements.

     

    » Inquire about F3SJ Safety Light Curtain

 

Features

 

Multi-functional for Special Applications such as Finger Protection

 

The detection capability supports finger protection through use of 9-mm resolution. The F3SJ is equipped with various functions such as blanking, muting and the programming of warning zones. All settings can be done via an easy to use software tool. This tool simplifies installation that was previously complicated, thus reducing cost and increasing productivity.

 

Software Tool: Setting Parameters and Checking the System Status

 

PC Setting Tool: Beam alignment is easier.

With the SD Manager (PC setting tool), all parameters can be set and the system status can be checked with a personal computer. Complex settings are now simple to configure.

 

 

Finger Protection

 

Finger protection: detection capability of 9 mm

Even if the distance from the hazard is short, Omron offers a lineup that includes safety light curtains with a detection capability of 9 mm.
 

 

Versatile Muting Functions


Equipped with partial muting that disables only the beams where a workpiece passes through, and position detection muting that disables the beams while detecting the position of a machine or robot.

 

Partial muting

 

Partial muting

Position detection muting

 

Position detection muting



Blanking Function


If a part of the mechanical equipment is within the detection zone of the Safety Light Curtain, the relevant beams can be disabled. This is applicable to both non-moving and also moving parts.
 

Fixed blanking

Fixed blanking - the beam that would otherwise be constantly interrupted by the workbench is disabled.

Floating blanking

In this case, 2-beam floating blanking is set. If three or more beams are interrupted, the output goes OFF.


 

Warning Zone to Prevent Unnecessary Stoppage


Under normal use, if an intrusion occurs in the safety zone, the machine will stop immediately. However, use of a warning zone will only notify the operator that an intrusion has occurred. This can be used to prevent carelessness resulting in machine stoppage on the part of the operator.
 

Dividing the zone between series-connected sensors

 

Warning zone: dividing the zone between series connected sensors.

A single sensor zone can also be divided

 

Warning zone: A single sensor zone can also be divided

 

 

Series Connection Up To 10 m

Long protective height

Sensors with protective height of up to 2.5 m are available for applications that involve large-sized workpieces. And if you need to make changes in the future, you can always extend the protective height with series connections. Up to four sets, or 400 beams, can be serially-connected, and with series connection cables up to 15 m in length, applications can cover a wide area.

 

 

 

Laser Pointer Used to Easily Align the Beams

Use of the laser pointer allows simple alignment of the beams especially across long distances. This saves approximately 60% of installation time.
 

F3SJ Setup Time Comparison with/without the F39-PTJ


 

(Conditions: The time was measured from temporary
attachment to the pole until the light beam is detected with
an mounting distance of 3 m and no tilt to mounting pole.)

 

 

Achieving Muting Function without a Controller


The muting function temporarily disables the light curtain when an object must pass through the detection zone, such as when supplying a workpiece to your equipment. In the past, this function required a dedicated muting controller, but now it is built into the F3SJ.

 

To use the muting function, purchase the Muting Key Cap (F39-CN6) (sold separately). The muting function is enabled simply by replacing the Unit's cap with this Key Cap. In addition, a muting sensor that determines the muting timing, as well as a muting lamp that notices the muting status to other operators, should be connected to the F3SJ.

Use example of a muting key cap for F3SJ-A


The safety light curtain can be disabled when an AGV carrying a workpiece passes through.


[Built-in muting function] No controller required

Simply attach the Key Cap (sold separately) to the sensor

Top

 

Wire-saving Devices (Sold separately)

   
To Connect to Muting Sensors:

F39-TC5 Connector Terminal Box (Muting Terminals for F3SJ-A)

 

F39-TC5 Connector Terminal Box

 

Significantly reduces amount of wiring between Safety Light Curtains and Muting Sensors
  • Provides IP67 protection against water and dust.

  • Connection using connectors significantly reduces wiring work.

  • The wiring status can be checked at a glance with the LED indicators.

  • The Support Software can be connected, enabling on-site adjustment of a Light Curtain.

  Datasheet

 

 

 

To Connect to Safety Relays:

F3SP-T01 Safety Terminal Relay (for F3SJ-A[][][][]P[][])

 

F3SP-T01 Safety Terminal Relay

 

Simplifies wiring from Safety Light Curtains to the Safety Relay outputs
  • Simplifies wiring inside the panel and helps prevent incorrect wiring.

  • Terminals are numbered to make it easy to check terminal connections.

  • Replacement of relays is easy, improving maintainability.

  • Screw-less clamp terminals eliminate the need for extra tightening.

  • The Support Software can be connected, enabling on-site adjustment of Light Curtains.

  Datasheet

 

 

Top

 

See Related Products:


G7SA Safety Relay
 

Safety Relay

 

 

G7SA

Compact, Slim Relays with guided contact structure ensures safety and conforms to EN standards.

G9SP Programmable Safety Controller
 

Programmable Safety Controller

 

 

G9SP

Configurable Safety Controller with flexible range suits any system.