Standards Certification

CPM1A Programmable Controller

 

EN/IEC Standards

 

Model

CE Marking

Basic Requirements of Machinery Directive/Low-voltage Directive

Basic Requirements of EMC Directive

(Certification Body: Self declaration)

Applicable Standard No.

Certification Body

EMI Standard No.

EMS Standard No.

CPM1A-10CDR-A-V1

Yes

EN61131-2

Self-declaration

EN61131-2

EN61131-2

CPM1A-10CDR-D-V1

Yes

Not Applicable

――

EN61131-2

EN61131-2

CPM1A-10CDT1-A-V1

Yes

EN61131-2

Self-declaration

EN61131-2

EN61131-2

CPM1A-10CDT1-D-V1

Yes

Not Applicable

――

EN61131-2

EN61131-2

CPM1A-10CDT-A-V1

Yes

EN61131-2

Self-declaration

EN61131-2

EN61131-2

CPM1A-10CDT-D-V1

Yes

Not Applicable

――

EN61131-2

EN61131-2

CPM1A-20CDR-A-V1

Yes

EN61131-2

Self-declaration

EN61131-2

EN61131-2

CPM1A-20CDR-D-V1

Yes

EN61131-2

Self-declaration

EN61131-2

EN61131-2

CPM1A-20CDT1-A-V1

Yes

EN61131-2

Self-declaration

EN61131-2

EN61131-2

CPM1A-20CDT1-D-V1

Yes

Not Applicable

――

EN61131-2

EN61131-2

CPM1A-20CDT-A-V1

Yes

EN61131-2

Self-declaration

EN61131-2

EN61131-2

CPM1A-20CDT-D-V1

Yes

Not Applicable

――

EN61131-2

EN61131-2

CPM1A-20EDR1

Yes

EN61131-2

Self-declaration

EN61131-2

EN61131-2

CPM1A-20EDT

Yes

Not Applicable

――

EN61131-2

EN61131-2

CPM1A-20EDT1

Yes

Not Applicable

――

EN61131-2

EN61131-2

CPM1A-30CDR-A-V1

Yes

EN61131-2

Self-declaration

EN61131-2

EN61131-2

CPM1A-30CDR-D-V1

Yes

EN61131-2

Self-declaration

EN61131-2

EN61131-2

CPM1A-30CDT1-A-V1

Yes

EN61131-2

Self-declaration

EN61131-2

EN61131-2

CPM1A-30CDT1-D-V1

Yes

Not Applicable

――

EN61131-2

EN61131-2

CPM1A-30CDT-A-V1

Yes

EN61131-2

Self-declaration

EN61131-2

EN61131-2

CPM1A-30CDT-D-V1

Yes

Not Applicable

――

EN61131-2

EN61131-2

CPM1A-40CDR-A-V1

Yes

EN61131-2

Self-declaration

EN61131-2

EN61131-2

CPM1A-40CDR-D-V1

Yes

EN61131-2

Self-declaration

EN61131-2

EN61131-2

CPM1A-40CDT1-A-V1

Yes

EN61131-2

Self-declaration

EN61131-2

EN61131-2

CPM1A-40CDT1-D-V1

Yes

Not Applicable

――

EN61131-2

EN61131-2

CPM1A-40CDT-A-V1

Yes

EN61131-2

Self-declaration

EN61131-2

EN61131-2

CPM1A-40CDT-D-V1

Yes

Not Applicable

――

EN61131-2

EN61131-2

CPM1A-40EDR

Yes

EN61131-2

Self-declaration

EN61131-2

EN61131-2

CPM1A-40EDT

Yes

Not Applicable

――

EN61131-2

EN61131-2

CPM1A-40EDT1

Yes

Not Applicable

――

EN61131-2

EN61131-2

CPM1A-8ED

Yes

Not Applicable

――

EN61131-2

EN61131-2

CPM1A-8ER

Yes

EN61131-2

Self-declaration

EN61131-2

EN61131-2

CPM1A-8ET

Yes

Not Applicable

――

EN61131-2

EN61131-2

CPM1A-8ET1

Yes

Not Applicable

――

EN61131-2

EN61131-2

CPM1A-AD041

Yes

EN61131-2

Self-declaration

EN61000-6-4

EN61000-6-2

CPM1A-DA041

Yes

EN61131-2

Self-declaration

EN61000-6-4

EN61000-6-2

CPM1A-DRT21

Yes

EN61131-2

Self-declaration

EN61131-2

EN61131-2

CPM1A-MAD01

Yes

EN61131-2

Self-declaration

EN61131-2

EN61131-2

CPM1A-MAD11

Yes

EN61131-2

Self-declaration

EN61131-2

EN61131-2

CPM1A-SRT21

Yes

EN61131-2

Self-declaration

EN61131-2

EN61131-2

CPM1A-TS001

Yes

EN61131-2

Self-declaration

EN61131-2

EN61131-2

CPM1A-TS002

Yes

EN61131-2

Self-declaration

EN61131-2

EN61131-2

CPM1A-TS101

Yes

EN61131-2

Self-declaration

EN61131-2

EN61131-2

CPM1A-TS102

Yes

EN61131-2

Self-declaration

EN61131-2

EN61131-2

CPM1-CIF01

Yes

Not Applicable

――

EN61131-2

EN61131-2

CPM1-CIF11

Yes

Not Applicable

――

EN61131-2

EN61131-2

 

We issue documentation ("EC Declaration of Conformity") providing details on the level of conformance. Contact your OMRON representative if required.

 

 

UL Certifications

 

Model

Standard No.

File No.

Marking

Listed/ Recognized

Category

CPM1-CIF

UL508

E95399

UL

Listed

NRAQ/

NRAQ7

CPM1A/CP1W

UL or cULus

 

Note:

1. The above table lists series names. Ask your OMRON representative for details on specific model numbers.

2. Products that are certified for UL 1604 can be used in hazardous locations for Class I, Div. 2, Groups A, B, C, and D.

 

 

CSA Certification

 

Model

Standard No.

File No.

Class No.

CPM1A

CSA
C22.2 No.142

 LR51460

2252 01

 

Note:
1. The above table lists series names. Ask your OMRON representative for details on specific model numbers.
2. Models are also available with cUL certification for Canada. Refer to the pages on UL certification.

 

 

GL Certification Standards (German Marine Standards)

 








Model

Environmental category Requirement class

CPM1A / CPM1

C: EMC2

Class 3

 

 

LR Standards (UK Marine Standards)

 








                

Model

Environmental Category

ENV1 ENV2 ENV3 ENV4 ENV5 Remarks

CPM1A

   

*

 

* General Power distribution Zones


Note:

1. The above table lists series names. Ask your OMRON representative for details on specific model numbers.
2. Model certification has not been received for usage on the deck, in the bridge, or in locations subject to strong vibration.


Model certification for the LR (Lloyd's Register of Shipping) was made according to the LR Type Approval System Test Specification No. 1.

 

 

NK Certification (Japanese Marine Standards)

 








                

Model

CPM1A

 

Note:

1. The above table lists series names. Ask your OMRON representative for details on specific model numbers.
2. CS-series and CJ-series PLCs are certified for the bridge. When using a CS-series or CJ-series PLC on the bridge, attach a noise filter on the power supply line. Use the TAH-06-683 from Cosel Co., Ltd., for the noise filter.
3. Model certification has not been received for usage on the deck, in the bridge, or in locations subject to strong vibration.

Model certification for the NK (Nippon Kaiji Kyokai) was made according to Chapter 1, Part 7 of Guidance for the Approval and Type Approval of Materials and Equipment for Marine Use.

 

 

ABS Certification (US Marine Standards)

 








                

Model

ABS Rule System Category

CPM1A

2009

III

 

Note:

1. The above table lists series names. Ask your OMRON representative for details on specific model numbers.
2. Model certification has not been received for usage on the deck, in the bridge, or in locations subject to strong vibration.


Model certification for the ABS (American Bureau of Shipping) was made according to the Steel Vessel Rules.

 

 

CR Certification (Taiwanese Marine Standards)

 

Model

Certification No.

CPM1A / CPM1

Q-03-140

Note:
1. The above table lists series names. Ask your OMRON representative for details on specific model numbers.
2. Model certification has not been received for usage on the deck, in the bridge, or in locations subject to strong vibration.

Model certification for the CR (China Corporation Resister of Shipping) was made according to the VIII. 2. 11, Rule for the Construction and Classification of Steel Ships, 1997.

top