Industrial Automation|

Australia

Clearance Centre

Sitemap

Contact

OMRON IA Global

 
Submit Enquiry

Back To
 
CP1E Main Page


Member Area

Find out information related to CP1E.

Catalogs/Manuals

CAD Drawings

 


Related Contents

Product News

Selection Guide

RoHS Compliant Status

Select Country

 

Product Information

Product Index :: Automation Systems :: Programmable Controllers :: Micro PLCs

Standards Certification

CP1E Programmable Controller

 

EN/IEC Standards

 

Model

CE Marking

Basic Requirements of Machinery Directive/Low-voltage Directive

Basic Requirements of EMC Directive

(Certification Body: Self declaration)

Applicable Standard No.

Certification Body

EMI Standard No.

EMS Standard No.

CP1W-CIF12

Yes

Not Applicable

――

EN61131-2

EN61131-2

CP1W-CIF41

Yes

Not Applicable

――

EN61131-2

EN61131-2

CP1E-E10DR-A

Yes

EN61131-2

Self-declaration

EN61131-2

EN61131-2

CP1E-E10DT-A

Yes

EN61131-2

Self-declaration

EN61131-2

EN61131-2

CP1E-E10DT1-A

Yes

EN61131-2

Self-declaration

EN61131-2

EN61131-2

CP1E-E10DR-D

Yes

EN61131-2

Self-declaration

EN61131-2

EN61131-2

CP1E-E10DT-D

Yes

Not Applicable

――

EN61131-2

EN61131-2

CP1E-E10DT1-D

Yes

Not Applicable

――

EN61131-2

EN61131-2

CP1E-E14DR-A

Yes

EN61131-2

Self-declaration

EN61131-2

EN61131-2

CP1E-E20DR-A

Yes

EN61131-2

Self-declaration

EN61131-2

EN61131-2

CP1E-E30DR-A

Yes

EN61131-2

Self-declaration

EN61131-2

EN61131-2

CP1E-E40DR-A

Yes

EN61131-2

Self-declaration

EN61131-2

EN61131-2

CP1E-N14DR-A

Yes

EN61131-2

Self-declaration

EN61131-2

EN61131-2

CP1E-N14DT-A

Yes

EN61131-2

Self-declaration

EN61131-2

EN61131-2

CP1E-N14DT1-A

Yes

EN61131-2

Self-declaration

EN61131-2

EN61131-2

CP1E-N14DR-D

Yes

EN61131-2

Self-declaration

EN61131-2

EN61131-2

CP1E-N14DT-D

Yes

Not Applicable

――

EN61131-2

EN61131-2

CP1E-N14DT1-D

Yes

Not Applicable

――

EN61131-2

EN61131-2

CP1E-N20DR-A

Yes

EN61131-2

Self-declaration

EN61131-2

EN61131-2

CP1E-N20DT-A

Yes

EN61131-2

Self-declaration

EN61131-2

EN61131-2

CP1E-N20DT1-A

Yes

EN61131-2

Self-declaration

EN61131-2

EN61131-2

CP1E-N20DR-D

Yes

EN61131-2

Self-declaration

EN61131-2

EN61131-2

CP1E-N20DT-D

Yes

Not Applicable

――

EN61131-2

EN61131-2

CP1E-N20DT1-D

Yes

Not Applicable

――

EN61131-2

EN61131-2

CP1E-N30DR-A

Yes

EN61131-2

Self-declaration

EN61131-2

EN61131-2

CP1E-N30DT-A

Yes

EN61131-2

Self-declaration

EN61131-2

EN61131-2

CP1E-N30DT1-A

Yes

EN61131-2

Self-declaration

EN61131-2

EN61131-2

CP1E-N30DR-D

Yes

EN61131-2

Self-declaration

EN61131-2

EN61131-2

CP1E-N30DT-D

Yes

Not Applicable

――

EN61131-2

EN61131-2

CP1E-N30DT1-D

Yes

Not Applicable

――

EN61131-2

EN61131-2

CP1E-N40DR-A

Yes

EN61131-2

Self-declaration

EN61131-2

EN61131-2

CP1E-N40DT-A

Yes

EN61131-2

Self-declaration

EN61131-2

EN61131-2

CP1E-N40DT1-A

Yes

EN61131-2

Self-declaration

EN61131-2

EN61131-2

CP1E-N40DR-D

Yes

EN61131-2

Self-declaration

EN61131-2

EN61131-2

CP1E-N40DT-D

Yes

Not Applicable

――

EN61131-2

EN61131-2

CP1E-N40DT1-D

Yes

Not Applicable

――

EN61131-2

EN61131-2

CP1E-N60DR-A

Yes

EN61131-2

Self-declaration

EN61131-2

EN61131-2

CP1E-N60DT-A

Yes

EN61131-2

Self-declaration

EN61131-2

EN61131-2

CP1E-N60DT1-A

Yes

EN61131-2

Self-declaration

EN61131-2

EN61131-2

CP1E-N60DR-D

Yes

EN61131-2

Self-declaration

EN61131-2

EN61131-2

CP1E-N60DT-D

Yes

Not Applicable

――

EN61131-2

EN61131-2

CP1E-N60DT1-D

Yes

Not Applicable

――

EN61131-2

EN61131-2

CP1E-NA20DR-A

Yes

EN61131-2

Self-declaration

EN61131-2

EN61131-2

CP1E-NA20DT-D

Yes

Not Applicable

――

EN61131-2

EN61131-2

CP1E-NA20DT1-D

Yes

Not Applicable

――

EN61131-2

EN61131-2

 

We issue documentation ("EC Declaration of Conformity") providing details on the level of conformance. Contact your OMRON representative if required.

 

 

UL Certifications

 

Model

Standard No.

File No.

Marking

Listed/ Recognized

Category

CP1E

UL508
UL1604

E229703

cULus

Listed

NRAG/

NRAG7

 

Note:

1. The above table lists series names. Ask your OMRON representative for details on specific model numbers.

2. Products that are certified for UL 1604 can be used in hazardous locations for Class I, Div. 2, Groups A, B, C, and D.

 

 

LR Standards (UK Marine Standards)

 








                

Model

Environmental Category

ENV1 ENV2 ENV3 ENV4 ENV5 Remarks

CP1

 

   

*

 

* General Power distribution Zones


Note:

1. The above table lists series names. Ask your OMRON representative for details on specific model numbers.
2. Model certification has not been received for usage on the deck, in the bridge, or in locations subject to strong vibration.


Model certification for the LR (Lloyd's Register of Shipping) was made according to the LR Type Approval System Test Specification No. 1.

 

 

NK Certification (Japanese Marine Standards)

 








                

Model

CP1

 

Note:

1. The above table lists series names. Ask your OMRON representative for details on specific model numbers.
2. CS-series and CJ-series PLCs are certified for the bridge. When using a CS-series or CJ-series PLC on the bridge, attach a noise filter on the power supply line. Use the TAH-06-683 from Cosel Co., Ltd., for the noise filter.
3. Model certification has not been received for usage on the deck, in the bridge, or in locations subject to strong vibration.

Model certification for the NK (Nippon Kaiji Kyokai) was made according to Chapter 1, Part 7 of Guidance for the Approval and Type Approval of Materials and Equipment for Marine Use.

 

 

ABS Certification (US Marine Standards)

 








                

Model

ABS Rule System Category

CP1

2007

---

 

Note:

1. The above table lists series names. Ask your OMRON representative for details on specific model numbers.
2. Model certification has not been received for usage on the deck, in the bridge, or in locations subject to strong vibration.


Model certification for the ABS (American Bureau of Shipping) was made according to the Steel Vessel Rules.

 

 

BV Certification (French Marine Standards)

 








                

Model

CP1

Note:
1. The above table lists series names. Ask your OMRON representative for details on specific model numbers.
2. Model certification has not been received for usage on the deck, in the bridge, or in locations subject to strong vibration.
3. Refer to the product manuals for other application conditions.
Model certification for the BV (Bureau Veritas) was made according to the Bureau Veritas Rules for the Classification of Steel Ships.

 

 

DNV Certification (Norwegian Marine Standards)

 

Model

Location Class

Temperature

Humidity

Vibration

EMC

Enclosure

CP1

B

B

A

A*2

*3

 

*1. The C1000H-APS01, however, is "A."
*2. Install inside a metal enclosure.
*3. There are no enclosure requirements for OMRON products. Follow the DNV enclosure requirements specified separately for installation locations of the panel containing the product.


Note 1: The above table lists series names. Ask your OMRON representative for details on specific model numbers.
Note 2: Model certification has not been received for usage on the deck, in the bridge, or in locations subject to strong vibration.


Model certification for the DNV (Det Norske Veritas) was made according to the Environmental Test Specific for Instrument and Automation Equipment Standard for Certification No. 2.4.

top