Page top

page-top

Omron uses cookies to improve your experience on this website. By continuing to use the website, you hereby agree to our Privacy and Cookie Policy

Lead Contents

Detecting the Level of Sea Water

FAQ No. FAQ00718

Primary Contents

Question

What would be an appropriate 61F Floatless Level Controllers, Electrode Holders, and Electrodes for detecting the level of seawater?

Answer

Use a low-sensitivity 61F (one with the suffix D on the model number), BS-1T Electrode Holders (titanium), and F03-01 Electrodes (titanium).

If BS-1 or BF-1 Electrode Holders is used, the stainless-steel electrode nuts will corrode and have to be regularly replaced.

Also, allow at least 1 m of space between Electrodes.