Control Panel Relay
|
Item
Model |
MY New Model |
MY3, MY[]-02, MY[]F |
MYK |
LY |
|
Appearance |
 |
![MY3, MY[]-02, MY[]F](my.gif) |
 |
 |
|
Features |
Versatile relay, ideal for power and
sequence control applications, meets many other application
requirements. |
Versatile relay, ideal for power and
sequence control applications, meets many other application
requirements. |
Magnetic latching relay ideal
for memory and data transmission
circuits. |
Compact, general-purpose 15-A and
10-A relays ideal for many applications. |
|
Contact Ratings |
Contact form |
DPDT |
4PDT |
DPDT |
3PDT |
4PDT |
DPDT |
SPDT |
DPDT |
3DPT |
4DPT |
|
Mechanism |
Single |
Single |
Bifur-cated |
Single |
Single |
Single |
Bifur-cated |
Single |
Single
|
Bifur-cated |
Single |
|
Material |
Ag |
Au-clad+Ag |
Ag |
Ag |
Au-Plated+Ag |
Au-Plated+Ag |
Ag-alloy |
Ag |
Ag-alloy |
|
Rated Load *
(Resistive Load) |
5A at 250 VAC/ 30VDC |
3A at 250 VAC/ 30 VDC |
5A at 220 VAC/24VDC |
3A at 220 VAC/24VDC |
3A at 220 VAC / 24 VDC |
15A at 110
VAC/ 24 VDC |
10A at 110
VAC/ 24 VDC |
5A at 110
VAC/ 24 VDC |
10 A at
110 VAC/24 VDC |
|
Maximum switched
current |
10A |
5A |
5A |
3A |
3A |
15A |
10A |
7A |
10A |
|
Failure rate
(reference value) |
1 mA at 5 VDC |
1 mA at 1 VDC |
100 ľA at 1 VDC |
1mA at 5 VDC |
1 mA at 1 VDC |
100 ľA at 1 VDC |
1 mA at 1 VDC |
100 mA at 5 VDC |
10 mA at 5 VDC |
100 mA at 5 VDC |
|
Coil Ratings |
Rated Voltage |
6 to
100/110 VDC
6 to
220/240 VAC |
6 to
100/110 VDC
6 to
220/240 VAC |
6 to 24
VDC
6 to 100
VAC |
6 to
100/110 VDC
6 to
220/240 VAC |
|
Power consumption
(approx.) |
0.9 W (DC)
0.9 to 1.2
VA (AC) |
0.9 W (DC)
0.9 to 1.2
VA (AC) |
Set: 1.3 W
(DC)
0.6 to 0.9
VA (AC)
Reset: 0.6
W (DC)
0.2 to 0.5
VA (AC) |
0.9 W (DC)
0.9 to 1.2
VA (AC) |
1.4 W (DC)
1.6 to 2.0
VA (AC) |
1.5 W (DC)
1.95 to
2.5
VA (AC) |
|
Endurance |
Mechanical |
50 x 10 6
(AC), 100 x 106
(DC) |
20 x 10 6 |
50 x 10 6
(AC)
100 x 10 6
(DC) |
20 x 10 6 |
100 x 10 6 |
50 x 106
(AC), 100 x 106 (DC) |
|
Electrical |
500 x 10ł |
200 x 10ł |
100 x 10ł |
500 x
10ł |
500 x
10ł |
200 x
10ł |
100 x
10ł |
200 x 10ł |
200 x 10ł |
500 x 10ł |
200 x 10ł |
|
Dielectric Strength |
Between coil and
contacts |
2,000 VAC
for 1 min. |
2,000 VAC
for 1 min. |
1,500 VAC
for 1 min. |
2,000 VAC
for 1 min. |
|
Between contacts of
different polarities |
2,000 VAC
for 1 min. |
2,000 VAC
for 1 min. |
1,500 VAC
for 1 min. |
-- |
2,000 VAC
for 1 min. |
|
Between contacts of
same polarity |
1,000 VAC
for 1 min. |
1,000 VAC
for 1 min. |
1,000 VAC
for 1 min. |
1,000 VAC
for 1 min. |
|
Between set and
reset coil |
-- |
-- |
1,000 VAC
for 1 min. |
--- |
|
Ambient temperature |
55°C to
70°C |
55°C to
70°C |
55°C to
60°C |
25°C to
55°C |
25°C to
40°C |
|
Function |
Mechanical indicator
LED indicator
Built-in diode
Built-in CR
Test button
Arc barriers |
LED indicator
Built-in diode
Arc barriers |
Latching
Mechanical indicator |
LED
indicator
Built-in diode
Built-in CR
Test
button |
|
Sealing |
Cased
(unsealed) |
Cased
(unsealed) |
Cased
(unsealed) |
Cased
(unsealed) |
|
Terminal
construction ** |
 |
 |
 |
 |
|
Approved standards |
      |
   |
-- |
     |
* Click on product model to view
product information.
top
|
|
Item
Model |
G2AK
Latching Type |
MK-I/-S |
G7T I/O |
G2RS |
|
Appearance |
 |
 |
 |
 |
|
Features |
Magnetic
latching version of G2A ideal
for sequence control.
|
Exceptionally reliable
general-purpose relay
features mechanical
indicator/test
button.
|
These
super-slim relays each
measure
only 29 x 10 x 32 mm
(W x D x
H) and come in AC
and DC
input models as well as SPST-NO
and SPST-NC output
models. |
Reliable
and unique test button models now available. High
switching power (1 pole: 10 A). Highly
functional socket also available.
|
|
Contact Ratings |
Contact form |
DPDT |
DPDT/3PDT |
SPST-NO, SPST-NC, SPDT |
SPST-NO |
SPDT |
DPDT |
|
Mechanism |
Bifurcated
|
Single |
Input: Bifurcated crossbar
Output: Single |
Bifurcated
|
Single |
Bifur-cated |
Single |
|
Material |
Movable: Au-clad+Ag
Stationary: Ag/Pd |
Ag |
Input: AgAu+Ag
Output: AgSnIn |
Ag-alloy |
|
Rated Load *
(Resistive Load) |
0.3 A at 110 VAC, 5,000,000 operations min.
0.5 A at 24 VDC, 5,000,000 operations min. |
10 A (NO),
5 A (NC) at
250 VAC/28
VDC |
Input: 1 A
at 24 VDC, 50,000 operations min.
10 mA at
24 VDC, 10,000,000 operations min.
Output: 5
A at 24 VDC, 1,000,000 operations min. |
1A at
250 VAC/ 30 VDC |
10A at
250 VAC/ 30 VDC |
1A at
250 VAC/ 30 VDC |
5 A at
250 VAC/30 VDC |
|
Maximum switched
current |
AC: 1A
DC: 3A |
10A |
Input: 1A
Output: 5A |
1A |
10A |
1A |
5A |
|
Failure rate
(reference value) |
1 mA at 100 m VDC |
10 mA at 1 VDC |
Input: 100
ľA at 1 VDC
Output: 10
mA at 5 VDC |
1 mA at 5 VDC |
100 mA at 5 VDC |
1 mA at 5 VDC |
10 mA at 5 VDC |
|
Coil Ratings |
Rated Voltage |
6 to 48 VDC
6 to 100
VAC |
6 to 125
VDC;
6 to
200/220 VAC |
110/120
VAC,
220/240
VAC,
12 VDC, 24
VDC 100/110 VDC |
5 to
100 VDC
12 to
240 VAC |
|
Power consumption
(approx.) |
Set: 2 to 2.2 W (DC); 1.6 to 2 VA (AC)
Reset: 1 to 1.2 W (DC); 0.5 to 1.2 VA (AC)
|
1.5 W (DC)
2.3 to 2.7
VA (AC)
|
0.7 VA
(AC)
0.5 W (DC) |
0.53 W (DC)
0.7 to 0.9 VA (AC)
|
|
Endurance |
Mechanical |
5 x 10 6 |
5 x 10 6 |
50 x 10 6 |
10 x 10 6
(AC), 20 x 106
(DC) |
|
Electrical |
5,000 x 10ł |
500 x 10ł |
Input: 500 x 10ł
Output: 1,000 x 10ł |
100 x 10ł |
|
Dielectric Strength |
Between coil and
contacts |
1,500 VAC
for 1 min. |
2,000 VAC
for 1 min. |
2,000 VAC
for 1 min. |
5,000 VAC
for 1 min. |
|
Between contacts of
different polarities |
1,500 VAC
for 1 min. |
2,000 VAC
for 1 min. |
-- |
-- |
3,000 VAC
for 1 min. |
|
Between contacts of
same polarity |
700 VAC
for 1 min. |
1,000 VAC
for 1 min. |
1,000 VAC
for 1 min. |
1,000 VAC
for 1 min. |
|
Between set and
reset coil |
1,000 VAC
for 1 min. |
-- |
-- |
--- |
--- |
|
Ambient temperature |
10°C to
40°C |
10°C to
40°C |
40°C to
70°C |
40°C to
70°C |
|
Function |
Latching (double binding)
Arc barriers
Mechanical indicator
|
Mechanical indicator |
Built-in mechanical operation
indicator
|
LED
indicator
Test
button
Built-in diode
|
|
Sealing |
Cased
(unsealed)
Fully sealed |
Cased
(unsealed) |
Closed/cased |
Cased
(unsealed) |
|
Terminal
construction ** |
 |
|
|
 |
|
Approved standards |
 |
     |
  |
     |
* Click on product model to view product information.
top
|
|
Item
Model |
G2A
|
G2A-434
Fully sealed type |
MM |
MMK
Latching type |
|
Appearance |
 |
 |
 |
 |
|
Features |
Four-pole, highly reliable miniature power relay ideal for
sequence control.
|
Fully sealed version of G2A that
performs well in adverse environments. |
Versatile relay satisfying most
applications. |
Mechanical latching relay boasting a wide variety of models.
|
|
Contact Ratings |
Contact form |
4PDT |
4PDT |
DPDT |
3PDT |
4PDT |
DPDT |
3PDT |
DPDT+DPST-NO |
|
Mechanism |
Bifurcated crossbar
|
Single |
Single |
|
Material |
Movable: Au-clad+Ag/Pd
Stationary: Ag/Pd |
Ag |
Ag |
|
Rated Load *
(Resistive Load) |
0.3 A at 110 VAC, 5,000,000 operations min.
0.5 A at 24 VDC, 5,000,000 operations min. |
15 (7.5) A
at 220 VAC, 500,000 operations min.
10 (5) A at 24 VDC, 500,000 operations min.
|
10 (5) A
at 220 VAC, 500,000 operations min.
7 (4) A at 24 VDC, 500,000 operations min. |
|
Maximum switched
current |
AC: 1A
DC: 3A |
AC: 0.7A
DC: 2A |
15 (7.5) A |
10 (5) A |
|
Failure rate
(reference value) |
1 mA at 100 m VDC |
10 mA at 5 VDC |
10 mA at 5 VDC |
|
Coil Ratings |
Rated Voltage |
6 to 100
VDC 6 to
200/220 VAC |
6 to
200/220 VDC
6 to 240 VAC
|
6 to
200/220 VDC
6 to 200/(220) VAC
|
|
Power consumption
(approx.) |
1.1 W (DC)
1.4
VA (AC)
|
2.1W (DC)
3.5 VA (AC) |
2.7W (DC)
5.1 VA (AC) |
Set: 2.1 W (DC)
3.5 VA (AC)
Reset: 2.8 W (DC)
4.1 VA (AC)
|
Set: 2.7 W (DC)
6 VA (AC)
Reset: 2.8 W (DC)
4.1 VA (AC) |
|
Endurance |
Mechanical |
100 x 10 6 |
5 x 10 6 |
2.5 x 10 6 |
|
Electrical |
5,000 x 10ł |
500 x 10ł |
500 x 10ł |
|
Dielectric Strength |
Between coil and
contacts |
1,500 VAC
for 1 min. |
2,000 VAC
for 1 min. |
2,000 VAC
for 1 min. |
|
Between contacts of
different polarities |
1,500 VAC
for 1 min. |
2,000 VAC
for 1 min. |
2,000 VAC
for 1 min. |
|
Between contacts of
same polarity |
700 VAC
for 1 min. |
1,500 VAC
for 1 min. |
1,500 VAC
for 1 min. |
|
Between set and
reset coil |
-- |
-- |
2,000 VAC
for 1 min. |
|
Ambient temperature |
10°C to
40°C |
10°C to
55°C |
10°C to
55°C |
|
Function |
Mechanical indicator
LED indicator
Arc barriers
Built-in diode
MBB contact |
Operation
indicator
Built-in diode
|
Latching
DC-Switching
|
|
Sealing |
Cased
(unsealed) |
Fully
sealed |
Open
Cased (Unsealed) |
Open
Cased (Unsealed) |
|
Terminal
construction ** |
 |
 |
  |
  |
|
Approved standards |
 |
  |
-- |
-- |
* Click on product model to view product information.
|
|
top
|
|
|
|
 |
|