Product Index :: Automation Systems :: Programmable Terminals :: NT Series (Basic HMI)

NT31/NT31C Programmable Terminal


NT31/NT31C Programmable Terminal

 

Download Product Brochure

* Ordering information

* Specifications

* Configurations

* Dimensions, and etc

 

  can be found in our PDF brochure.

 

 

 

Better SYSMAC Compatibility and Easier-to-use Support Software. Improved Functionality Based on Complete Research in Designing, Development, and Production Site Needs.

 

To keep in pace with the progress of information technology on production sites, more advanced and more diversified functions are continuously required from operator interfaces. OMRON continuously researches the use of operator interfaces at all stages of application.

 

OMRON scrutinizes system compatibility, design efficiency, and maintenance, and has now achieved new versions of the NT631/NT31 Programmable Terminals with the functionality required by the users. Experience the remarkable progress of new NT631/NT31.

 

Features

 

Improved SYSMAC Compatibility for Easier System Construction

 

Device Monitor Function

The device monitor function makes it possible to read and write I/O memory data and display consecutive sections of PLC data areas. This function greatly improves the efficiency of PLC setup work, including set value input into the Special I/O Units and checks on the settings. Data can be read from I/O memory from a user-created screen to enable application on maintenance screens for monitoring.

 

DeviceNet Monitor Function

 

Programmable Console Functions

Ladder Programs written in mnemonics can be written and read through the NT631/NT31 screens for easy on-site system maintenance.

 

Screen Capture: Registration monitor, Error log and Continuous monitor

 

Full-area Access to SYSMAC CS1-series PLCs over High-speed NT Link

Connect to SYSMAC CS1-series PLC over High-speed NT Link

  • The industry's highest serial communications speed

  • Up to eight NT631/NT31 Units can be connected to a single port

  • Extends to a maximum of 500m

  • Essentially the same performance is achieved for NT Links with eight PTs as for an NT Link with a single PT (for refreshing numeric displays)

Connect to SYSMAC CS1-series PLC over High-speed NT Link

 

 

 

Improved Support Software  

 

Greatly Improved Support

Windows Look and Feel environment ensures easy operation, allowing anyone to create screens quickly and easily. The enhanced ON/OFF simulation function of the NT631/NT31 and easy application of existing screen data accelerate product development and designing.

 

Screen Capture: Edit screen, Application Manager and Symbol Manager

  • The arrow keys on the keyboard are used to move elements dot by dot

  • Displays element and cursor coordinates

  • The window being manipulated can be displayed or no displayed

  • Zooms up to 800%

ON/OFF Simulation on Edit Screen

Easily confirm the ON/OFF status of lamps and touch switches from  personal computer.

 

A simulated screen with standard elements provided can include touch switches can lamps that are easily registered with the Symbol Manager.

 

ON/OFF Simulation on Edit Screen

 

Many Standard Elements Provided

In addition to ISO symbols, approximately 1,000 lamp and touch switch elements are provided as standard elements. The preview function makes it possible to select and edit these elements with ease. Furthermore, it is possible to copy image tables or library tables independently.

 

Screen Capture

 

The image editor makes it possible to enlarge or reduce images

 

Screen Capture: Image Editor

 

 

 

GUI Environment for Easier Operations

 

Error Log Viewer

Double-click the error message to track down the error on the screen.

 

Screen Capture: Error Log Viewer

 

Filter

The filter function makes editing easier by displaying only the elements you select for modification.

Screen Capture: Filter

 

Online Help

Click the Help icon Help Icon

whenever you are not sure how to proceed. The information you need will appear by touching the elements on the screen.

 

Screen Capture: Online Help

 

 

Element Alignment

Elements can be top-, bottom-, left-, right-, or center-aligned automatically

 

Screen Capture: Element Alignment

 

 

Search Function

Screen Capture: Search Function

 

Translation Support Utility

Currently, translation for label contents in NTST can only be performed manually by opening and editing individual visible string contents in NTST, before downloading applications to a different language PT. The Translation Support Utility enables you to load the memory map image file (.MMI) for the source language and be able to translate the new string contents of the application and generate independent memory map files (.MMI) for the specified target language.

 

Screen Capture: Translation Support Utility

 

System Requirements

  • CPU : Pentium 100MHz min.

  • RAM : 32 MB min.

  • Hard Disk

  • Software capacity : 17 MB

  • Installer : 3 MB

  • Sample elements : 32 MB

  • OS : Windows 95/98 or Windows NT4.0

  • Media : CD-ROM

 

Functions and Enhanced Display Versatility

 

Mathematical/Interlock Function

The mathematical/interlock function can be used to create screens, greatly eliminating the size of ladder programs and enabling easier program modifications. This function allows up to five arithmetic operations (i.e., addition, subtraction, multiplications, and division) or Boolean operations (e.g., AND and OR) to be used on the NT631/NT31.

Mathematical table

Screen Capture: Mathematical Table

Interlock

Screen Capture: Interlock

 

Example: While the machine is not ready to operate, "Standby" will appear on the tough switch prohibiting the operation of the machine. When the machine is ready to operate, "Ready" will appear on the touch switch permitting command inputs.

 

Example Diagram

 

Multi-window Display Allows Optimum Screen Application

Up to three windows can be displayed simultaneously. A window can be moved with the touch of a finger. Furthermore, windows can be opened and closed from the PLC using operations in the Windows Control Area.

 

Screen Capture: Multi-window Display

 

 

 

Easy Maintenance

 

System Program Transfer

By transferring a new system program, function and performance can be updated without changing hardware.

System Programs Provided

  • For NT31/NT631 : OMRON version (Memory Link) and Mitsubishi version

  • For NT30/NT620 : OMRON version, Mitsubishi version, and Memory Link version

  • For NT11S

Screen Capture: System Program Transfer

 

Memory Unit Provides Easy and Immediate Screen Data Transfer

Simply attaching the Memory Unit to the back of the NT631/NT31 allows easy transfer of screens. Up to 2 banks can be registered and it is possible to transfer both system programs and screen data.

 

Memory Unit

 

Special Utility to Transfer Screen Data

It is possible to transfer screens by using a special software application instead of the NT Support Software. The software application can be set up separately.

 

Screen Capture: Special Utility to Transfer Screen Data

 

Screen Data Checked without Programmable Controller Connected

The NT631/NT31 displays screens, such as lamps, touch switches, and memory table numbers, without the PLC connected, to enable efficient debugging.

Screen Capture: Screen Data Checked without Programmable Controller Connected

 

DeviceNet Compatible

The NT631/NT31 is compatible with DeviceNet for I/O allocations and message communications, promoting further standardization. With the DeviceNet Interface Unit (under development) mounted, version 1 or older versions of NT631/NT31 can also be connected to the DeviceNet.

 

DeviceNet Connection Diagram

 

English, European, and Asian Language Support

Both European and English languages are supported by -EV1 models. Furthermore, models supporting Chinese, Taiwanese, and Korean are available. Contact your OMRON representative for details.

 

 

Conformance to IP65F Ensures a High Degree of Resistance to the Environment

The NT631/NT31 has a flush-surface construction and is highly resistive to severe operating environments. The front panel conforms to IP65F.

 

 IP: International Protection

  6: Resistant to dust (protected from solid objects)

  5: Resistant to water spray from any direction (protected from water immersion)

  F: Resistant to oil drops or sprayed oil

 

The NT631/NT31 cannot be used in locations where it will be subjected to oil spray over a long period of time.

 

Conformity to International Standards Ensures Suitability for Exports

The NT631/NT31 conforms to UL/CSA standards and EC Directives.

 

UL, SA, CE

 

Protective Cover (Sold Separately)

 

Protective Cover

 

 Material

 Polyester film

 Mounting method

 Double-sided tape

 Model numbers

 NT31C-KBA05

 NT631C-KBA05

 

The Protective Cover protects the surface of the NT631/NT31 from oil, dust, or fingerprints.