Industrial Automation|

Australia

Clearance Centre

Sitemap

Contact

OMRON IA Global

 
Submit Enquiry

Back To
 
CRS1-RPT01 Main Page


Member Area

Find out information related to CRS1-RPT01.

Catalogs/Manuals

CAD Drawings

 


Related Contents

Selection Guide

Select Country

View CRS1-RPT01 standards in your country.

Australia Philippines
India Singapore
Indonesia Thailand
Malaysia New Zealand

 

Product Information

Product Index :: Automation Systems :: Industrial Network :: CompoNet :: Slaves (I/O Terminals)

Standards Certification

CRS1-RPT01

CompoNet Repeater Unit

 

EN/IEC Standards

 

Model

CE Marking

Basic Requirements of Machinery Directive/Low-voltage Directive

Basic Requirements of EMC Directive

(Certification Body: Self declaration)

Applicable Standard No.

Certification Body

EMI Standard No.

EMS Standard No.

CRS1-RPT01

Yes

Not Applicable

――

EN61000-6-4/
EN61131-2

EN61000-6-2/
EN61131-2

 

We issue documentation ("EC Declaration of Conformity") providing details on the level of conformance. Contact your OMRON representative if required.
*Ask your OMRON representative for details.

 

 

UL Certifications

 

Model

Standard No.

File No.

Marking

Listed/Recognized

Category

CRS1-RPT01

UL508
UL1604

E198998

RU

Recognized

NRAG2

 

Note:

1. The above table lists series names. Ask your OMRON representative for details on specific model numbers.

2. Products that are certified for UL 1604 can be used in hazardous locations for Class I, Div. 2, Groups A, B, C, and D.


Description of Hazardous Locations:
[Class]
   Class I: Locations in which flammable gases or vapors may be present in the air in sufficient quantities to be explosive or ignitable.
   Class II: Locations in which combustible dust is present.
   Class III: Locations in which easily ignitable fibers or flyings are present
   but are not airborne in sufficient quantities to ignite.
[Division]
   Division 1: Locations in which explosive or ignitable material is normally present or is present at certain times.
   Division 2: Locations in which explosive or ignitable material is not normally present (but may accidentally exist).
[Group]
   Class I:
   Group A: Acetylene
   Group B: Combustible gas/vapor, example: hydrogen
   Group C: Combustible gas/vapor, example: ethylene
   Group D: Combustible gas/vapor, example: propane

 

 

LR Standards (UK Marine Standards)

 

Model

Environmental Category

ENV1 ENV2 ENV3 ENV4 ENV5 Remarks

CRS1-RPT01

     

 

Note:

1. The above table lists series names. Ask your OMRON representative for details on specific model numbers.
2. Model certification has not been received for usage on the deck, in the bridge, or in locations subject to strong vibration.

 

 

DNV Certification (Norwegian Marine Standards)

 








Model

Location Class

Temperature

Humidity

Vibration

EMC

Enclosure

CRS1-RPT01

B

B

A

A

*

 

* There are no enclosure requirements for OMRON products. Follow the DNV enclosure requirements specified separately for installation locations of the panel containing the product.


Note 1: The above table lists series names. Ask your OMRON representative for details on specific model numbers.
Note 2: Model certification has not been received for usage on the deck, in the bridge, or in locations subject to strong vibration.

 

 

NK Certification (Japanese Marine Standards)

 

Model

CRS1-RPT01

 

Note:

1. The above table lists series names. Ask your OMRON representative for details on specific model numbers.
2. Model certification has not been received for usage on the deck, in the bridge, or in locations subject to strong vibration.
Model certification for the NK (Nippon Kaiji Kyokai) was made according to Chapter 1, Part 7 of Guidance for the Approval and Type Approval of Materials and Equipment for Marine Use.

top