Frequently Asked Questions

Ultrasonic Sensor Topic: Linearity

 

FAQ No. FAQ01368

 

Question

 

What is linearity of Ultrasonic Sensors?

 

 

Answer
 

Linearity is the error in the linear output compared to the ideal value that describes the relationship between the distance and the linear output when the temperature and voltage are at fixed values.

 

Linear Output Curve

(Example)


The linearity of E4PA-LS50-M1 Ultrasonic Sensor is ±1% FS (FS: 500 mm − 60 mm = 440 mm).

Converting this to a dimension,
Dimension error = ±1% × 440 mm= ±4.4 mm
Therefore, compared with the ideal direct line, there is an error of ±4.4 mm max.

 

 

 

Other Ultrasonic Sensor FAQs

 What is a sensing area?

 What is resonance?

 What is synchronous operation?